Back to results

Virginia Tech

Relamping hotel guestrooms to decrease operating costs

Abstract

dc:description.abstract

The purpose of this study was to determine if the hotel industry could reduce a portion of its operating costs used for unnecessary lighting expenses. The study was conducted at the Donaldson Brown Center in Blacksburg, Virginia with 32 hotel guests participating. Data was collected to determine light fixture usage during periods of guestroom inactivity (inactive is defined as periods after the guest had checked-in but was out of the guestroom). Two treatment rooms and two control rooms were monitored to determine inactivity of the room, usage of light fixtures, and usage of daylight. Light levels and wattage readings were taken to determine consistency in light levels of the lamps and energy used by the different fixture/lamp combinations in each of the four rooms. One treatment room and one control room were on the east side of the building and the other treatment and control room were on the west side. The test rooms were evaluated to insure that all interior variables (i.e., structural configuration, size, materials and finishes, furnishings, light fixtures, and HV AC system) were controlled. The only features changed in the guest rooms were lamps housed in the fixtures of the two treatment rooms where the ceiling fixtures were relamped with two 16 watt compact fluorescent lamps (CFLs) and portable fixtures were relamped with one 18 watt CFL. Standard incandescent lamps were used in the control rooms. It was found that the time lights arc left on in inactive rooms can amount to a considerable portion of a hotels operating costs for energy usage. Results show a 64-71 % reduction in energy consumed by CFLs compared to incandescent lamps. Fixtures housed with incandescent lamps cost an average of $.008 per hour to run compared to those lamped with CFLs which cost $.003 per hour to run. Through total or strategic relamping of fixtures, operating costs for electric lighting can be cut by more than 50% and energy resources would be saved. Implemented environmental strategies could then be used as a marketing tool to attract environmentally conscious consumers.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Housing, Interior Design, and Resource Management
Department dc:contributor.department
Housing, Interior Design, and Resource Management
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kieliszewski, Cheryl A.
Chair dc:contributor.committeechair
  • Bowker, Jeanette E.
Committee members dc:contributor.committeemember
  • Parsons, Robert A.
  • Marshall-Baker, Anna

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-02132009-171036
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/41026

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Kieliszewski, Cheryl A.. Relamping hotel guestrooms to decrease operating costs. masters thesis, Virginia Tech, 1996. http://hdl.handle.net/10919/41026