{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/40945"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/40945","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The six phase rectifier as a power source for operating DC motors","abstract":"It can definitely be stated that the results of the experiments show that almost no appreciable adverse effects on the test motor result from six phase rectifier operation, The efficiency was unaffected by rectifier operation, The temperature rise with rectifier operation was roughly within 5°C of that obtained with DC generator input, The commutation was not adversely affected when using the rectifier, These statements apply even when the rectifier is operated at half voltage, a condition giving very much more ripple than the full voltage ripple.","abstract_html":"It can definitely be stated that the results of the experiments show that almost no appreciable adverse effects on the test motor result from six phase rectifier operation, The efficiency was unaffected by rectifier operation, The temperature rise with rectifier operation was roughly within 5°C of that obtained with DC generator input, The commutation was not adversely affected when using the rectifier, These statements apply even when the rectifier is operated at half voltage, a condition giving very much more ripple than the full voltage ripple.","abstract_has_math":false,"creators":["Ebert, Harry K., Jr."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Murray, W. A."],"committee_members":["Whittemore, John A.","Pardue, Louis A."],"year":1953,"date_issued":"1953-06-05","date_published":"1953-06-05","updated_at":"2026-07-22T22:20:43Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02062013-040116"],"render_values":[{"text":"etd-02062013-040116","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/40945","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Murray, W. A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Whittemore, John A.","Pardue, Louis A."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Ebert, Harry K., Jr."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:28:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:28:40Z","2013-02-06"]},{"key":"dc:date.issued","label":"Date","values":["1953-06-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02062013-040116"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/40945"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["It can definitely be stated that the results of the experiments show that almost no appreciable adverse effects on the test motor result from six phase rectifier operation, The efficiency was unaffected by rectifier operation, The temperature rise with rectifier operation was roughly within 5°C of that obtained with DC generator input, The commutation was not adversely affected when using the rectifier, These statements apply even when the rectifier is operated at half voltage, a condition giving very much more ripple than the full voltage ripple."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The six phase rectifier as a power source for operating DC motors"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Murray, W. A."],"dc:contributor.committeemember":["Whittemore, John A.","Pardue, Louis A."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Ebert, Harry K., Jr."],"dc:date.accessioned":["2014-03-14T21:28:40Z"],"dc:date.available":["2014-03-14T21:28:40Z","2013-02-06"],"dc:date.issued":["1953-06-05"],"dc:description.abstract":["It can definitely be stated that the results of the experiments show that almost no appreciable adverse effects on the test motor result from six phase rectifier operation, The efficiency was unaffected by rectifier operation, The temperature rise with rectifier operation was roughly within 5°C of that obtained with DC generator input, The commutation was not adversely affected when using the rectifier, These statements apply even when the rectifier is operated at half voltage, a condition giving very much more ripple than the full voltage ripple."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-02062013-040116"],"dc:identifier.uri":["http://hdl.handle.net/10919/40945"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["The six phase rectifier as a power source for operating DC motors"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute"]},"updated_at":"2026-07-22T22:20:43Z"}