Back to results

Virginia Tech

The effect of lateral bracing on the dynamic response of wood floor systems

Abstract

dc:description.abstract

This thesis presents the results of an extensive study of several types of lateral bracing for solid-sawn and parallel-chord truss floor systems. Three solid-sawn floor bracing systems were evaluated: X-bridging, full-depth solid blocking, and finally, post-tensioned solid-blocking. Five different truss bracing systems were investigated: bottom-chord bracing, steel X-bracing, strong-back bracing, and the bracing combinations of X-plus bottom-chord bracing, and strong-back plus bottom chord bracing were evaluated. A total of seven, 4.9m x 4.9m floor specimens were constructed. Four 38 x 286 mm (2 x 12 inch nominal), solid-sawn wood joist floors were constructed for evaluation of the solid-sawn bracing systems. Three 305 mm (12 inch) deep, bottom-chord bearing, metal plate connected, parallel-chord truss floors were constructed to evaluate the truss floor bracing systems. Both floor systems utilized joist/truss spacings of 610 mm (24 inches) on center, and were covered with 18.3 mm (23/32 inch) thick, tongue-in-groove, plywood sheathing. The bracing systems were evaluated at different live load levels and boundary conditions. The bracing systems were subjected to both static and dynamic loadings. The effect of the bracing systems were determined based on four parameters: one static, and three dynamic. The percent change in concentrated load carried by the loaded joist was used as the static test parameter. The effect, if any, of the bracing systems on the modal resonant frequencies, separation of frequencies, and damping characteristics of the floor systems, were used as dynamic parameters. Future research and design recommendations were given in the conclusion chapter.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1993

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stark, John W.

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-01242009-063313
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/40752

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Stark, John W.. The effect of lateral bracing on the dynamic response of wood floor systems. masters thesis, Virginia Tech, 1993. http://hdl.handle.net/10919/40752