{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/40575"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/40575","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Epoxy matrix composite strain sensing and cure monitoring","abstract":"An adaptation of an extrinsic Fabry-Perot interferometer (EFPI) strain sensor is described, which permits the state of cure of an epoxy matrix to be monitored, when the sensor is embedded in a polymeric matrix composite. By using a glass rod with a retroreflecting end for the target fiber in the EFPI sensor, the intensity of the light reflected depends on the refractive index of the host matrix, if a low coherence source is used. As the epoxy cross-links during cure, the refractive index of the epoxy will increase to a value exceeding that of the target fiber. The resulting increased loss in the fiber can be detected at the sensor output and correlated to the state of cure of the epoxy. After cure, the sensor may be operated as a conventional extrinsic Fabry-Perot interferometric strain sensor if a coherent source is used. Using the modified extrinsic Fabry-Perot sensor, we monitor the cure of Devcon® 5-Minute® Epoxy, and show that it cures in approximately 60 minutes.","abstract_html":"An adaptation of an extrinsic Fabry-Perot interferometer (EFPI) strain sensor is described, which permits the state of cure of an epoxy matrix to be monitored, when the sensor is embedded in a polymeric matrix composite. By using a glass rod with a retroreflecting end for the target fiber in the EFPI sensor, the intensity of the light reflected depends on the refractive index of the host matrix, if a low coherence source is used. As the epoxy cross-links during cure, the refractive index of the epoxy will increase to a value exceeding that of the target fiber. The resulting increased loss in the fiber can be detected at the sensor output and correlated to the state of cure of the epoxy. After cure, the sensor may be operated as a conventional extrinsic Fabry-Perot interferometric strain sensor if a coherent source is used. Using the modified extrinsic Fabry-Perot sensor, we monitor the cure of Devcon® 5-Minute® Epoxy, and show that it cures in approximately 60 minutes.","abstract_has_math":false,"creators":["Sanderson, James M."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-07-22T22:19:42Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01102009-063758"],"render_values":[{"text":"etd-01102009-063758","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/40575","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Sanderson, James M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:26:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:26:52Z","2009-01-10"]},{"key":"dc:date.issued","label":"Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01102009-063758"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/40575"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An adaptation of an extrinsic Fabry-Perot interferometer (EFPI) strain sensor is described, which permits the state of cure of an epoxy matrix to be monitored, when the sensor is embedded in a polymeric matrix composite. By using a glass rod with a retroreflecting end for the target fiber in the EFPI sensor, the intensity of the light reflected depends on the refractive index of the host matrix, if a low coherence source is used. As the epoxy cross-links during cure, the refractive index of the epoxy will increase to a value exceeding that of the target fiber. The resulting increased loss in the fiber can be detected at the sensor output and correlated to the state of cure of the epoxy. After cure, the sensor may be operated as a conventional extrinsic Fabry-Perot interferometric strain sensor if a coherent source is used. Using the modified extrinsic Fabry-Perot sensor, we monitor the cure of Devcon® 5-Minute® Epoxy, and show that it cures in approximately 60 minutes."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Epoxy matrix composite strain sensing and cure monitoring"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Sanderson, James M."],"dc:date.accessioned":["2014-03-14T21:26:52Z"],"dc:date.available":["2014-03-14T21:26:52Z","2009-01-10"],"dc:date.issued":["1994"],"dc:description.abstract":["An adaptation of an extrinsic Fabry-Perot interferometer (EFPI) strain sensor is described, which permits the state of cure of an epoxy matrix to be monitored, when the sensor is embedded in a polymeric matrix composite. By using a glass rod with a retroreflecting end for the target fiber in the EFPI sensor, the intensity of the light reflected depends on the refractive index of the host matrix, if a low coherence source is used. As the epoxy cross-links during cure, the refractive index of the epoxy will increase to a value exceeding that of the target fiber. The resulting increased loss in the fiber can be detected at the sensor output and correlated to the state of cure of the epoxy. After cure, the sensor may be operated as a conventional extrinsic Fabry-Perot interferometric strain sensor if a coherent source is used. Using the modified extrinsic Fabry-Perot sensor, we monitor the cure of Devcon® 5-Minute® Epoxy, and show that it cures in approximately 60 minutes."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-01102009-063758"],"dc:identifier.uri":["http://hdl.handle.net/10919/40575"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Epoxy matrix composite strain sensing and cure monitoring"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:42Z"}