Back to results

Virginia Tech

Evaluation of Graft Pretension Effects in Anterior Cruciate Ligament Reconstruction: A Series of In Vitro and In Vivo Experiments

Abstract

dc:description.abstract

The purpose of this dissertation was to study the effects of graft pretension in anterior cruciate ligament (ACL) reconstruction through a series of experiments. First, an in vitro study of 5 human knees was conducted to determine if intact joint kinematics could be restored when using the ideal graft - the intrinsic ACL. The ACL tibial insertion site was freed, and pretensions of 0, 10, 20, 30, and 40 N were applied to the ligament using a custom designed load cell connection. Kinematics during a simulated active extension were compared to those of the intact knee. Intact knee kinematics were not restored. Pretensions that best restored tibial anterior/posterior translation and internal/external rotation ranged from 0-40 N. Furthermore, the pretensions that best restored these kinematic variables were widely disparate in two specimens. Second, the in vitro kinematics during a simulated active extension of human and porcine knees were compared and contrasted both prior to and following transection of the ACL. The ACL limited: (1) tibial anterior translation in both species, (2) tibial internal rotation in humans, and (3) tibial external rotation in pigs. Differences in kinematic patterns for tibial internal/external rotation and abduction/adduction between the species was explained by requirements for biped and quadruped stances. Third, the mechanical characteristics of porcine patellar tendon (PT) were investigated by uniaxial tensile testing at two strain rates. Patella-PT-tibia complexes from freshly sacrificed skeletally immature and mature animals were loaded to failure at elongation rates of 20 and 200 mm/min. Both strain rate and skeletal maturity significantly affected failure mode, tangent modulus, and ultimate stress of the tendons, and hence are important considerations in the mechanical evaluation of porcine PT. Fourth, ACL reconstructions were performed using pretensions of 10 or 20 N in an in vivo porcine model with a specially designed load cell/telemetry system to monitor graft load. Graft pretension was seen to increase during fixation with interference screws. Following sacrifice at 4 weeks, tissues were mechanically, histologically, and biochemically analyzed. A pretension of 20 N resulted in a tissue more similar to the intrinsic ACL.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Engineering Mechanics
Department dc:contributor.department
Engineering Mechanics
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ringer, Geoffrey Wadsworth
Chair dc:contributor.committeechair
  • Wayne, Jennifer S.
Committee members dc:contributor.committeemember
  • Landgraf, Ronald W.
  • Zuelzer, Wilhelm A.
  • Henneke, Edmund G. II
  • Grant, John Wallace

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-31198-203618
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/40494

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Ringer, Geoffrey Wadsworth. Evaluation of Graft Pretension Effects in Anterior Cruciate Ligament Reconstruction: A Series of In Vitro and In Vivo Experiments. doctoral thesis, Virginia Tech, 1998. http://hdl.handle.net/10919/40494