{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/39732"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/39732","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Aspects of the microwave induced plasma as an element selective detector for supercritical fluid chromatography and supercritical fluid extraction","abstract":"The introduction of supercritical CO₂ at packed column supercritical fluid chromatography (SFC) flow rates is shown to significantly affect the excitation characteristics of a helium microwave induced plasma (He MIP). In this work, the influence of CO₂ on specific atomic and ionic transitions of Cl, Br, I, P, and S is described. Also presented is the determined relationship between transition energy and degree of signal depression resulting from the introduction of CO₂ to the plasma. Attempts to enhance the emission signals of non-metals by introducing H₂ into a He MIP are discussed. The inadequacy of excitation temperature, ionization temperature, rotational temperature, and electron number density measurements to determine the effect of CO₂ on the excitation characteristics of a He MIP is also described. However, application of kinetic theory and a recently developed theory on charge transfer allows a reasonable series of mechanisms to be developed that describe the excitation processes of a He MIP to which supercritical CO₂ is added. The remainder of this work describes a direct interface between a supercritical fluid extraction (SFE) vessel and an Ar MIP for the purpose of element selective detection. The response of the plasma to the introduction of sample via SFE at a variety of extraction temperatures, pressures, and sample concentrations is presented.","abstract_html":"The introduction of supercritical CO₂ at packed column supercritical fluid chromatography (SFC) flow rates is shown to significantly affect the excitation characteristics of a helium microwave induced plasma (He MIP). In this work, the influence of CO₂ on specific atomic and ionic transitions of Cl, Br, I, P, and S is described. Also presented is the determined relationship between transition energy and degree of signal depression resulting from the introduction of CO₂ to the plasma. Attempts to enhance the emission signals of non-metals by introducing H₂ into a He MIP are discussed. The inadequacy of excitation temperature, ionization temperature, rotational temperature, and electron number density measurements to determine the effect of CO₂ on the excitation characteristics of a He MIP is also described. However, application of kinetic theory and a recently developed theory on charge transfer allows a reasonable series of mechanisms to be developed that describe the excitation processes of a He MIP to which supercritical CO₂ is added. The remainder of this work describes a direct interface between a supercritical fluid extraction (SFE) vessel and an Ar MIP for the purpose of element selective detection. The response of the plasma to the introduction of sample via SFE at a variety of extraction temperatures, pressures, and sample concentrations is presented.","abstract_has_math":false,"creators":["Ducatte, Gerald Roger"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Chemistry","degree_department":"Chemistry","school":null,"contributors":[],"advisors":[],"committee_chairs":["Long, Gary L.","Anderson, Mark R."],"committee_members":["Merola, Joseph S.","McNair, Harold M.","Taylor, Larry T."],"year":1993,"date_issued":"1993-12-05","date_published":"1993-12-05","updated_at":"2026-07-22T22:19:41Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10102005-131615"],"render_values":[{"text":"etd-10102005-131615","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/39732","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Long, Gary L.","Anderson, Mark R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Merola, Joseph S.","McNair, Harold M.","Taylor, Larry T."]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry"]},{"key":"dc:creator","label":"Author","values":["Ducatte, Gerald Roger"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:20:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:20:46Z","2005-10-10"]},{"key":"dc:date.issued","label":"Date","values":["1993-12-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10102005-131615"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/39732"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The introduction of supercritical CO₂ at packed column supercritical fluid chromatography (SFC) flow rates is shown to significantly affect the excitation characteristics of a helium microwave induced plasma (He MIP). In this work, the influence of CO₂ on specific atomic and ionic transitions of Cl, Br, I, P, and S is described. Also presented is the determined relationship between transition energy and degree of signal depression resulting from the introduction of CO₂ to the plasma. Attempts to enhance the emission signals of non-metals by introducing H₂ into a He MIP are discussed. The inadequacy of excitation temperature, ionization temperature, rotational temperature, and electron number density measurements to determine the effect of CO₂ on the excitation characteristics of a He MIP is also described. However, application of kinetic theory and a recently developed theory on charge transfer allows a reasonable series of mechanisms to be developed that describe the excitation processes of a He MIP to which supercritical CO₂ is added. The remainder of this work describes a direct interface between a supercritical fluid extraction (SFE) vessel and an Ar MIP for the purpose of element selective detection. The response of the plasma to the introduction of sample via SFE at a variety of extraction temperatures, pressures, and sample concentrations is presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Aspects of the microwave induced plasma as an element selective detector for supercritical fluid chromatography and supercritical fluid extraction"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Long, Gary L.","Anderson, Mark R."],"dc:contributor.committeemember":["Merola, Joseph S.","McNair, Harold M.","Taylor, Larry T."],"dc:contributor.department":["Chemistry"],"dc:creator":["Ducatte, Gerald Roger"],"dc:date.accessioned":["2014-03-14T21:20:46Z"],"dc:date.available":["2014-03-14T21:20:46Z","2005-10-10"],"dc:date.issued":["1993-12-05"],"dc:description.abstract":["The introduction of supercritical CO₂ at packed column supercritical fluid chromatography (SFC) flow rates is shown to significantly affect the excitation characteristics of a helium microwave induced plasma (He MIP). In this work, the influence of CO₂ on specific atomic and ionic transitions of Cl, Br, I, P, and S is described. Also presented is the determined relationship between transition energy and degree of signal depression resulting from the introduction of CO₂ to the plasma. Attempts to enhance the emission signals of non-metals by introducing H₂ into a He MIP are discussed. The inadequacy of excitation temperature, ionization temperature, rotational temperature, and electron number density measurements to determine the effect of CO₂ on the excitation characteristics of a He MIP is also described. However, application of kinetic theory and a recently developed theory on charge transfer allows a reasonable series of mechanisms to be developed that describe the excitation processes of a He MIP to which supercritical CO₂ is added. The remainder of this work describes a direct interface between a supercritical fluid extraction (SFE) vessel and an Ar MIP for the purpose of element selective detection. The response of the plasma to the introduction of sample via SFE at a variety of extraction temperatures, pressures, and sample concentrations is presented."],"dc:description.degree":["Ph. D."],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-10102005-131615"],"dc:identifier.uri":["http://hdl.handle.net/10919/39732"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Aspects of the microwave induced plasma as an element selective detector for supercritical fluid chromatography and supercritical fluid extraction"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:41Z"}