{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/39715"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/39715","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Dielectric loss determination using perturbation","abstract":"A dielectric filled cavity structure is currently being used to estimate the dielectric constant and loss factor over a wide range of frequencies of a dielectric material which fills the cavity structure [Saed, 1987]. A full field analysis is used to compute the effective complex permittivity of the sample material based on reflection coefficient measurements of the cavity structure and associated geometrical dimensions. The method has previously been used successfully to determine the dielectric constant of materials, but limitations in the Inethod have created difficulties in accurate determination of the dielectric loss factor. The effective loss in this method yields an estimate of the total cavity loss, including both the dielectric loss and that of the cavity conductor walls. In this dissertation a perturbation approach is used to separate the conductor loss from the total loss. The loss-free full-field analysis is used to determine the electric current at the conductor boundaries. This current is used to evaluate the perturbed power dissipated in the cavity walls based on known conductor properties. By subtracting the loss due to the conductor walls from the total loss measured in the structure, the dielectric loss and the resultant dielectric loss factor may be estimated. Measurements are presented for sample dielectric materials. The dielectric loss tangents computed by this new technique improve the unperturbed estimates in the microwave frequency range.","abstract_html":"A dielectric filled cavity structure is currently being used to estimate the dielectric constant and loss factor over a wide range of frequencies of a dielectric material which fills the cavity structure [Saed, 1987]. A full field analysis is used to compute the effective complex permittivity of the sample material based on reflection coefficient measurements of the cavity structure and associated geometrical dimensions. The method has previously been used successfully to determine the dielectric constant of materials, but limitations in the Inethod have created difficulties in accurate determination of the dielectric loss factor. The effective loss in this method yields an estimate of the total cavity loss, including both the dielectric loss and that of the cavity conductor walls. In this dissertation a perturbation approach is used to separate the conductor loss from the total loss. The loss-free full-field analysis is used to determine the electric current at the conductor boundaries. This current is used to evaluate the perturbed power dissipated in the cavity walls based on known conductor properties. By subtracting the loss due to the conductor walls from the total loss measured in the structure, the dielectric loss and the resultant dielectric loss factor may be estimated. Measurements are presented for sample dielectric materials. The dielectric loss tangents computed by this new technique improve the unperturbed estimates in the microwave frequency range.","abstract_has_math":false,"creators":["Andrawis, Madeleine Y."],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Davis, William A.","Riad, Sedki Mohamed"],"committee_members":["Besieris, Ioannis M.","Elshabini-Riad, Aicha A.","Kohler, Werner E.","Brown, Gary S."],"year":1991,"date_issued":"1991-12-08","date_published":"1991-12-08","updated_at":"2026-07-22T22:19:39Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10102005-131557"],"render_values":[{"text":"etd-10102005-131557","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/39715","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Davis, William A.","Riad, Sedki Mohamed"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Besieris, Ioannis M.","Elshabini-Riad, Aicha A.","Kohler, Werner E.","Brown, Gary S."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Andrawis, Madeleine Y."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:20:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:20:43Z","2005-10-10"]},{"key":"dc:date.issued","label":"Date","values":["1991-12-08"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10102005-131557"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/39715"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A dielectric filled cavity structure is currently being used to estimate the dielectric constant and loss factor over a wide range of frequencies of a dielectric material which fills the cavity structure [Saed, 1987]. A full field analysis is used to compute the effective complex permittivity of the sample material based on reflection coefficient measurements of the cavity structure and associated geometrical dimensions. The method has previously been used successfully to determine the dielectric constant of materials, but limitations in the Inethod have created difficulties in accurate determination of the dielectric loss factor. The effective loss in this method yields an estimate of the total cavity loss, including both the dielectric loss and that of the cavity conductor walls. In this dissertation a perturbation approach is used to separate the conductor loss from the total loss. The loss-free full-field analysis is used to determine the electric current at the conductor boundaries. This current is used to evaluate the perturbed power dissipated in the cavity walls based on known conductor properties. By subtracting the loss due to the conductor walls from the total loss measured in the structure, the dielectric loss and the resultant dielectric loss factor may be estimated. Measurements are presented for sample dielectric materials. The dielectric loss tangents computed by this new technique improve the unperturbed estimates in the microwave frequency range."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Dielectric loss determination using perturbation"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Davis, William A.","Riad, Sedki Mohamed"],"dc:contributor.committeemember":["Besieris, Ioannis M.","Elshabini-Riad, Aicha A.","Kohler, Werner E.","Brown, Gary S."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Andrawis, Madeleine Y."],"dc:date.accessioned":["2014-03-14T21:20:43Z"],"dc:date.available":["2014-03-14T21:20:43Z","2005-10-10"],"dc:date.issued":["1991-12-08"],"dc:description.abstract":["A dielectric filled cavity structure is currently being used to estimate the dielectric constant and loss factor over a wide range of frequencies of a dielectric material which fills the cavity structure [Saed, 1987]. A full field analysis is used to compute the effective complex permittivity of the sample material based on reflection coefficient measurements of the cavity structure and associated geometrical dimensions. The method has previously been used successfully to determine the dielectric constant of materials, but limitations in the Inethod have created difficulties in accurate determination of the dielectric loss factor. The effective loss in this method yields an estimate of the total cavity loss, including both the dielectric loss and that of the cavity conductor walls. In this dissertation a perturbation approach is used to separate the conductor loss from the total loss. The loss-free full-field analysis is used to determine the electric current at the conductor boundaries. This current is used to evaluate the perturbed power dissipated in the cavity walls based on known conductor properties. By subtracting the loss due to the conductor walls from the total loss measured in the structure, the dielectric loss and the resultant dielectric loss factor may be estimated. Measurements are presented for sample dielectric materials. The dielectric loss tangents computed by this new technique improve the unperturbed estimates in the microwave frequency range."],"dc:description.degree":["Ph. D."],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-10102005-131557"],"dc:identifier.uri":["http://hdl.handle.net/10919/39715"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Dielectric loss determination using perturbation"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:39Z"}