{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/39093"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/39093","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The transport of high concentrations of carbon monoxide to locations remote from the burning compartment","abstract":"An experimental study was conducted to measure the effects of oxygen entrainment on the transport of CO in building fires, and to develop a procedure for estimating CO levels during a building fire. Experiments were performed with an insulated 1/4-scale room connected to the side of a 1/4-scale hallway forming a L-shape. Measurements of CO, unburned hydrocarbons (UHC), CO₂, and O₂ concentrations and temperature were performed within the compartment, the hallway and post-hallway in the exhaust duct. The level of CO transported to remote locations from the burning room was hypothesized to be most significantly affected by the oxygen entrainment into the compartment fire gases entering the hallway. With a fixed size opening connecting the compartment to the hallway, the oxygen entrainment was varied by changing the depth of the oxygen deficient hallway upper-layer. In experiments where compartment fire gases entered the hallway completely surrounded by oxygen deficient combustion gases, post-hallway CO yields were measured to be as much as 23% greater than CO yields measured inside the compartment, despite the presence of external burning. With deep upper-layers in the hallway, geometric effects were not observed to significantly affect the transported level of CO. Instead, the CO level was a function of the compartment stoichiometry and the occurrence of external burning.","abstract_html":"An experimental study was conducted to measure the effects of oxygen entrainment on the transport of CO in building fires, and to develop a procedure for estimating CO levels during a building fire. Experiments were performed with an insulated 1/4-scale room connected to the side of a 1/4-scale hallway forming a L-shape. Measurements of CO, unburned hydrocarbons (UHC), CO₂, and O₂ concentrations and temperature were performed within the compartment, the hallway and post-hallway in the exhaust duct. The level of CO transported to remote locations from the burning room was hypothesized to be most significantly affected by the oxygen entrainment into the compartment fire gases entering the hallway. With a fixed size opening connecting the compartment to the hallway, the oxygen entrainment was varied by changing the depth of the oxygen deficient hallway upper-layer. In experiments where compartment fire gases entered the hallway completely surrounded by oxygen deficient combustion gases, post-hallway CO yields were measured to be as much as 23% greater than CO yields measured inside the compartment, despite the presence of external burning. With deep upper-layers in the hallway, geometric effects were not observed to significantly affect the transported level of CO. Instead, the CO level was a function of the compartment stoichiometry and the occurrence of external burning.","abstract_has_math":false,"creators":["Lattimer, Brian Y."],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Vandsburger, Uri"],"committee_members":["Roby, Richard J.","Ganeshan, B.","Jaasma, Dennis R.","Saito, K."],"year":1996,"date_issued":"1996-12-05","date_published":"1996-12-05","updated_at":"2026-07-22T22:19:09Z","subjects":["entrainment","transport","carbon monoxide","structure","fire"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08082007-120032"],"render_values":[{"text":"etd-08082007-120032","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/39093","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Vandsburger, Uri"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Roby, Richard J.","Ganeshan, B.","Jaasma, Dennis R.","Saito, K."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Lattimer, Brian Y."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:17:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:17:28Z","2007-08-08"]},{"key":"dc:date.issued","label":"Date","values":["1996-12-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["entrainment","transport","carbon monoxide","structure","fire"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08082007-120032"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/39093"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental study was conducted to measure the effects of oxygen entrainment on the transport of CO in building fires, and to develop a procedure for estimating CO levels during a building fire. Experiments were performed with an insulated 1/4-scale room connected to the side of a 1/4-scale hallway forming a L-shape. Measurements of CO, unburned hydrocarbons (UHC), CO₂, and O₂ concentrations and temperature were performed within the compartment, the hallway and post-hallway in the exhaust duct. The level of CO transported to remote locations from the burning room was hypothesized to be most significantly affected by the oxygen entrainment into the compartment fire gases entering the hallway. With a fixed size opening connecting the compartment to the hallway, the oxygen entrainment was varied by changing the depth of the oxygen deficient hallway upper-layer. In experiments where compartment fire gases entered the hallway completely surrounded by oxygen deficient combustion gases, post-hallway CO yields were measured to be as much as 23% greater than CO yields measured inside the compartment, despite the presence of external burning. With deep upper-layers in the hallway, geometric effects were not observed to significantly affect the transported level of CO. Instead, the CO level was a function of the compartment stoichiometry and the occurrence of external burning."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The transport of high concentrations of carbon monoxide to locations remote from the burning compartment"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Vandsburger, Uri"],"dc:contributor.committeemember":["Roby, Richard J.","Ganeshan, B.","Jaasma, Dennis R.","Saito, K."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Lattimer, Brian Y."],"dc:date.accessioned":["2014-03-14T21:17:28Z"],"dc:date.available":["2014-03-14T21:17:28Z","2007-08-08"],"dc:date.issued":["1996-12-05"],"dc:description.abstract":["An experimental study was conducted to measure the effects of oxygen entrainment on the transport of CO in building fires, and to develop a procedure for estimating CO levels during a building fire. Experiments were performed with an insulated 1/4-scale room connected to the side of a 1/4-scale hallway forming a L-shape. Measurements of CO, unburned hydrocarbons (UHC), CO₂, and O₂ concentrations and temperature were performed within the compartment, the hallway and post-hallway in the exhaust duct. The level of CO transported to remote locations from the burning room was hypothesized to be most significantly affected by the oxygen entrainment into the compartment fire gases entering the hallway. With a fixed size opening connecting the compartment to the hallway, the oxygen entrainment was varied by changing the depth of the oxygen deficient hallway upper-layer. In experiments where compartment fire gases entered the hallway completely surrounded by oxygen deficient combustion gases, post-hallway CO yields were measured to be as much as 23% greater than CO yields measured inside the compartment, despite the presence of external burning. With deep upper-layers in the hallway, geometric effects were not observed to significantly affect the transported level of CO. Instead, the CO level was a function of the compartment stoichiometry and the occurrence of external burning."],"dc:description.degree":["Ph. D."],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-08082007-120032"],"dc:identifier.uri":["http://hdl.handle.net/10919/39093"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["entrainment","transport","carbon monoxide","structure","fire"],"dc:title":["The transport of high concentrations of carbon monoxide to locations remote from the burning compartment"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:09Z"}