Back to results

Virginia Tech

Response to parameter variation of a one-inch diameter hydrocyclone for pyritic sulfur removal

Abstract

dc:description.abstract

An investigation of the literature showed that as the diameter of a hydrocyclone was decreased, smaller particles could be effectively separated on the basis of specific gravity. Consequently, a laboratory scale study was conducted to determine the possibility of removing pyritic sulfur from fine coal using a 1.0" diameter hydrocyclone. A 1.0" diameter hydrocyclone was constructed from stainless steel. The hydrocyclone was fabricated with easily interchangable parts that permitted rapid variations in the inlet diameter, apex discharge diameter, vortex finder diameter, vortex finder position, and cone angle. The feed pressure to the hydrocyclone could also be varied. A recirculating system was used. Synthetic material was used in place of actual coal during this investigation. The synthetic material, made from casting resin and barium sulfate, duplicated the coal with respect to particle size, shape, and specific gravity distribution. The synthetic coal had the advantage of not degrading during the course of the experiment. Three coals were simulated for the purposes of this experiment. Pocahontas 113 coal served as the "light" coal, the Hagy seam was selected as the "medium" coal, and coal from the Cortes area of New Mexico was chosen as the "heavy" coal. By optimizing the 1.0" diameter hydrocyc1one for these three coals, it would be possible to extend the results of the investigation to any coal. The results of the investigation showed that the 1.0" diameter hydrocyclone was an effective device for removing pyritic sulfur from 65 x 200 mesh coal. The results for the minus 200 mesh size fraction were not good. A smaller diameter hydrocyclone would be necessary in order to effectively process the minus 200 mesh size fraction.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Environmental Sciences and Engineering
Department dc:contributor.department
Environmental Sciences and Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1975

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Amundson, Lynn Vinzant
Chair dc:contributor.committeechair
  • Foreman, W. E.
Committee members dc:contributor.committeemember
  • King, Paul H.
  • Stephens, N. T.
  • Payne, William W.
  • Lucas, J. Richard
  • Sears, C. E.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-05192010-020327
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/37840

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Amundson, Lynn Vinzant. Response to parameter variation of a one-inch diameter hydrocyclone for pyritic sulfur removal. doctoral thesis, Virginia Tech, 1975. http://hdl.handle.net/10919/37840