Back to results

Virginia Tech

Objective Image Quality of CRT Displays under Ambient Glare: Assessing the ISO 9241-7 Ergonomic Technical Standard

Abstract

dc:description.abstract

This thesis assessed the readability of CRT displays viewed under ambient lighting conditions and then evaluated the findings with respect to the ISO 9241-7 standard. More specifically, two phases of work were conducted in this thesis. In Phase 1, seven monitors were evaluated photometrically according to the ISO 9241-7 standard to determine whether they were Class I, II, or III in positive and negative polarity. Additionally, six filters were attached to each of the monitors and their ISO Class also was assessed. All monitor/filter combinations yielded either Class I or II in positive polarity and Class II, III or failed in negative polarity. In Phase 2, fourteen participants were asked to read Tinker passages from seven display/filter combinations (tested in Phase 1) under five lighting conditions and two screen polarities. The purpose of the Phase 2 was to determine if people perform differently for Class I, II, or III monitor/filter combinations. The dependent measures were the time to read the Tinker passage (reading time) and the ability to identify the out of context word in each passage (accuracy). An Analysis of Variance was used to determine the significant effects of reading time and accuracy. The ANOVA results indicate that specular glare interferes significantly more with reading time than does diffuse glare. Diffuse (200 lux) and Specular reading times also were correlated against two ISO metrics: screen image luminance ratio (Diffuse, 200 lux) and specular reflection luminance ratio. Reading times did not correlate with the screen image luminance ratio, but they did correlate with one of the ISO specular reflection luminance ratios. The results of this thesis indicate that the ISO standard should not equally weight the screen image and the specular reflection luminance ratios. Additionally, the results indicate that it is not necessary to have separate ISO Classes for positive and negative polarity. Furthermore, people did not read differently for Class I, II, or III monitor/filter combinations. Finally, the data of this investigation provide an initial human factors database for use in assessing the validity of ISO 9241-7.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Industrial and Systems Engineering
Department dc:contributor.department
Industrial and Systems Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kempic, Joy
Chair dc:contributor.committeechair
  • Beaton, Robert J.
Committee members dc:contributor.committeemember
  • Beaton, Robert J.
  • Prestrude, Albert M.
  • Deighan, John

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-32498-133957
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/36622

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Kempic, Joy. Objective Image Quality of CRT Displays under Ambient Glare: Assessing the ISO 9241-7 Ergonomic Technical Standard. masters thesis, Virginia Tech, 1998. http://hdl.handle.net/10919/36622