Back to results

Virginia Tech

Floor Vibration Design Criterion For Cold-Formed C-Shaped Supported Residential Floor Systems

Abstract

dc:description.abstract

Annoying floor vibration due to normal human activity was investigated for cold-formed C-shaped residential floors systems. Dynamic impact and static loading tests were performed on twelve full size laboratory floors and five two-joist line laboratory floors to determine the influencing characteristics of annoying vibrations in metal framed floors. Similar tests were conducted on eleven floors located in existing houses. Subjective evaluation, in terms of annoying vibration levels, of all floors was recorded. Four existing floor vibration criteria were investigated: 1) Australian Standard. Domestic Metal Framing Code, 2) Swedish Building Technology Design Guide developed by Professor Sven Ohlsson, 3) United States Proposed Timber Floor Vibration Criterion developed by James Johnson, and 4) Canadian Timber Floor Criterion developed by Donald Onysko. Data collected from testing was used to determine which of the four existing criteria best classified the perceived vibration level of the floors. One criterion is suggested as the most suitable for predicting the perceived vibration level of metal framed residential floors. Three methods to predict the vertical deflection of a floor subject to a concentrated load at mid-bay were examined. The results of applying these methods to the laboratory floors were compared to the actual measured values. The method which correlated the best with the measured values was selected for use in the proposed criterion.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kraus, Cynthia A.
Chair dc:contributor.committeechair
  • Murray, Thomas M.
Committee members dc:contributor.committeemember
  • Easterling, William Samuel
  • Plaut, Raymond H.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-322517201974500
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/36612

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Kraus, Cynthia A.. Floor Vibration Design Criterion For Cold-Formed C-Shaped Supported Residential Floor Systems. masters thesis, Virginia Tech, 1997. http://hdl.handle.net/10919/36612