Back to results

Virginia Tech

Assessment of the Repeatability and Sensitivity of the Thermoelectric Perfusion Probe

Abstract

dc:description.abstract

The Thermoelectric Perfusion Probe is a completely electronic system that cyclically heats and cools tissue to measure blood perfusion. The probe produces the thermal event with a thermoelectric cooler and then measures the resulting heat flux and temperatures: the arterial temperature and the sensor temperature (the temperature between the heat flux gage and the skin). The Thermoelectric Perfusion Probe was validated and calibrated on a phantom tissue test stand, a system that simulates perfusion with known, controlled flow. With the new pressed sensor technology, a thermocouple sealed to a heat flux gage, the sensor temperature and the heat flux are simultaneously recorded. The pressed sensor tests validated the program used to predict perfusion for the Thermoelectric Perfusion Probe. This perfusion estimation program can determine the tissues perfusion regardless of how the thermal event is created (i.e. convective cooling, convective heating, conductive heating). Based on experimentation, the Thermoelectric Perfusion Probe displays good repeatability and sensitivity for continuously measuring perfusion. The sensitivity and repeatability of the Thermoelectric Perfusion Probe was proven when the perfusion estimates were compared to the perfusion estimates predicted by the Convective Perfusion Probe, a previously validated perfusion probe, and the CFD Flow Model, a computational model of the phantom tissue test stand.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ellis, Brent Earl
Chairs dc:contributor.committeechair
  • Scott, Elaine P.
  • Diller, Thomas E.
Committee member dc:contributor.committeemember
  • Lanz, Otto I.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-12202006-123743
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/36336

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Ellis, Brent Earl. Assessment of the Repeatability and Sensitivity of the Thermoelectric Perfusion Probe. masters thesis, Virginia Tech, 2006. http://hdl.handle.net/10919/36336