{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/35859"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/35859","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Thermal Performance Comparison of Three Integrated Thermal Solar Roof Collectors","abstract":"The integrated solar roof collector system can bring the house year-round energy saving benefit. In heating season, part of the space heating and preheating domestic hot water demand can be met by this integrated system. In the cooling season, cooling load reduction and preheating domestic hot water can be achieved by operating this system. The traditional solar thermal system is an add-on system rather than integrated, which increases the cost-benefit ratio. The current system is integrated with the roof structure. Except for the energy collecting benefit, it will reduce the material cost, labor cost and construction period. The objectives of this research is to estimate the energy performance of three collector configurations including space heating saving, and preheat hot water saving. This study also compares energy performance for the three collectors on two types of evaluated houses in Roanoke, Virginia.","abstract_html":"The integrated solar roof collector system can bring the house year-round energy saving benefit. In heating season, part of the space heating and preheating domestic hot water demand can be met by this integrated system. In the cooling season, cooling load reduction and preheating domestic hot water can be achieved by operating this system. The traditional solar thermal system is an add-on system rather than integrated, which increases the cost-benefit ratio. The current system is integrated with the roof structure. Except for the energy collecting benefit, it will reduce the material cost, labor cost and construction period. The objectives of this research is to estimate the energy performance of three collector configurations including space heating saving, and preheat hot water saving. This study also compares energy performance for the three collectors on two types of evaluated houses in Roanoke, Virginia.","abstract_has_math":false,"creators":["Xu, Zheng"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Architecture","degree_department":"Architecture","school":null,"contributors":[],"advisors":[],"committee_chairs":["Jones, James R."],"committee_members":["Schubert, Robert P.","Ermann, Michael G."],"year":2004,"date_issued":"2004-09-17","date_published":"2004-09-17","updated_at":"2026-07-22T22:19:04Z","subjects":["energy saving","Solar thermal system","heat collection"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11302004-105131"],"render_values":[{"text":"etd-11302004-105131","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/35859","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Jones, James R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Schubert, Robert P.","Ermann, Michael G."]},{"key":"dc:contributor.department","label":"Department","values":["Architecture"]},{"key":"dc:creator","label":"Author","values":["Xu, Zheng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:48:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:48:32Z","2007-12-29"]},{"key":"dc:date.issued","label":"Date","values":["2004-09-17"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Architecture"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["energy saving","Solar thermal system","heat collection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11302004-105131"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/35859"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The integrated solar roof collector system can bring the house year-round energy saving benefit. In heating season, part of the space heating and preheating domestic hot water demand can be met by this integrated system. In the cooling season, cooling load reduction and preheating domestic hot water can be achieved by operating this system. The traditional solar thermal system is an add-on system rather than integrated, which increases the cost-benefit ratio. The current system is integrated with the roof structure. Except for the energy collecting benefit, it will reduce the material cost, labor cost and construction period. The objectives of this research is to estimate the energy performance of three collector configurations including space heating saving, and preheat hot water saving. This study also compares energy performance for the three collectors on two types of evaluated houses in Roanoke, Virginia."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Thermal Performance Comparison of Three Integrated Thermal Solar Roof Collectors"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Jones, James R."],"dc:contributor.committeemember":["Schubert, Robert P.","Ermann, Michael G."],"dc:contributor.department":["Architecture"],"dc:creator":["Xu, Zheng"],"dc:date.accessioned":["2014-03-14T20:48:32Z"],"dc:date.available":["2014-03-14T20:48:32Z","2007-12-29"],"dc:date.issued":["2004-09-17"],"dc:description.abstract":["The integrated solar roof collector system can bring the house year-round energy saving benefit. In heating season, part of the space heating and preheating domestic hot water demand can be met by this integrated system. In the cooling season, cooling load reduction and preheating domestic hot water can be achieved by operating this system. The traditional solar thermal system is an add-on system rather than integrated, which increases the cost-benefit ratio. The current system is integrated with the roof structure. Except for the energy collecting benefit, it will reduce the material cost, labor cost and construction period. The objectives of this research is to estimate the energy performance of three collector configurations including space heating saving, and preheat hot water saving. This study also compares energy performance for the three collectors on two types of evaluated houses in Roanoke, Virginia."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-11302004-105131"],"dc:identifier.uri":["http://hdl.handle.net/10919/35859"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["energy saving","Solar thermal system","heat collection"],"dc:title":["Thermal Performance Comparison of Three Integrated Thermal Solar Roof Collectors"],"dc:type":["Thesis"],"thesis:degree_discipline":["Architecture"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:04Z"}