{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/35690"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/35690","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Simulation of Airflow and Heat Transfer in Buildings","abstract":"Energy usage in buildings has become a major topic of research in the past decade, driven by the increased cost of energy. Designing buildings to use less energy has become more important, and the ability to analyze buildings before construction can save money in design changes. Computational fluid dynamics (CFD) has been explored as a means of analyzing energy usage and thermal comfort in buildings. Existing research has been focused on simple buildings without much application to real buildings. The current study attempts to expand the research to entire buildings by modeling two existing buildings designed for energy efficient heating and cooling. The first is the Viipuri Municipal Library (Russia) and the second is the Margaret Esherick House (PA). The commercial code FLUENT is used to perform simulations to study the effect of varying atmospheric conditions and configurations of openings. Three heating simulations for the library showed only small difference in results with atmospheric condition or configuration changes. A colder atmospheric temperature led to colder temperatures in parts of the building. Moving the inlet only slightly changed the temperatures in parts of the building. The cooling simulations for the library had more drastic changes in the openings. All three cases showed the building cooled quickly, but the velocity in the building was above recommended ranges given by ASHRAE Standard 55. Two cooling simulations on the Esherick house differed only by the addition of a solar heat load. The case with the solar heat load showed slightly higher temperatures and less mixing within the house. The final simulation modeled a fire in two fireplaces in the house and showed stratified air with large temperature gradients.","abstract_html":"Energy usage in buildings has become a major topic of research in the past decade, driven by the increased cost of energy. Designing buildings to use less energy has become more important, and the ability to analyze buildings before construction can save money in design changes. Computational fluid dynamics (CFD) has been explored as a means of analyzing energy usage and thermal comfort in buildings. Existing research has been focused on simple buildings without much application to real buildings. The current study attempts to expand the research to entire buildings by modeling two existing buildings designed for energy efficient heating and cooling. The first is the Viipuri Municipal Library (Russia) and the second is the Margaret Esherick House (PA). The commercial code FLUENT is used to perform simulations to study the effect of varying atmospheric conditions and configurations of openings. Three heating simulations for the library showed only small difference in results with atmospheric condition or configuration changes. A colder atmospheric temperature led to colder temperatures in parts of the building. Moving the inlet only slightly changed the temperatures in parts of the building. The cooling simulations for the library had more drastic changes in the openings. All three cases showed the building cooled quickly, but the velocity in the building was above recommended ranges given by ASHRAE Standard 55. Two cooling simulations on the Esherick house differed only by the addition of a solar heat load. The case with the solar heat load showed slightly higher temperatures and less mixing within the house. The final simulation modeled a fire in two fireplaces in the house and showed stratified air with large temperature gradients.","abstract_has_math":false,"creators":["Stoakes, Preston John"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Battaglia, Francine"],"committee_members":["Ekkad, Srinath V.","Paul, Mark R."],"year":2009,"date_issued":"2009-10-30","date_published":"2009-10-30","updated_at":"2026-07-22T22:20:43Z","subjects":["Computational fluid dynamics","natural ventilation"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11132009-150648"],"render_values":[{"text":"etd-11132009-150648","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/35690","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Battaglia, Francine"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ekkad, Srinath V.","Paul, Mark R."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Stoakes, Preston John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:47:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:47:50Z","2009-12-01"]},{"key":"dc:date.issued","label":"Date","values":["2009-10-30"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computational fluid dynamics","natural ventilation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11132009-150648"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/35690"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Energy usage in buildings has become a major topic of research in the past decade, driven by the increased cost of energy. Designing buildings to use less energy has become more important, and the ability to analyze buildings before construction can save money in design changes. Computational fluid dynamics (CFD) has been explored as a means of analyzing energy usage and thermal comfort in buildings. Existing research has been focused on simple buildings without much application to real buildings. The current study attempts to expand the research to entire buildings by modeling two existing buildings designed for energy efficient heating and cooling. The first is the Viipuri Municipal Library (Russia) and the second is the Margaret Esherick House (PA). The commercial code FLUENT is used to perform simulations to study the effect of varying atmospheric conditions and configurations of openings. Three heating simulations for the library showed only small difference in results with atmospheric condition or configuration changes. A colder atmospheric temperature led to colder temperatures in parts of the building. Moving the inlet only slightly changed the temperatures in parts of the building. The cooling simulations for the library had more drastic changes in the openings. All three cases showed the building cooled quickly, but the velocity in the building was above recommended ranges given by ASHRAE Standard 55. Two cooling simulations on the Esherick house differed only by the addition of a solar heat load. The case with the solar heat load showed slightly higher temperatures and less mixing within the house. The final simulation modeled a fire in two fireplaces in the house and showed stratified air with large temperature gradients."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Simulation of Airflow and Heat Transfer in Buildings"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Battaglia, Francine"],"dc:contributor.committeemember":["Ekkad, Srinath V.","Paul, Mark R."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Stoakes, Preston John"],"dc:date.accessioned":["2014-03-14T20:47:50Z"],"dc:date.available":["2014-03-14T20:47:50Z","2009-12-01"],"dc:date.issued":["2009-10-30"],"dc:description.abstract":["Energy usage in buildings has become a major topic of research in the past decade, driven by the increased cost of energy. Designing buildings to use less energy has become more important, and the ability to analyze buildings before construction can save money in design changes. Computational fluid dynamics (CFD) has been explored as a means of analyzing energy usage and thermal comfort in buildings. Existing research has been focused on simple buildings without much application to real buildings. The current study attempts to expand the research to entire buildings by modeling two existing buildings designed for energy efficient heating and cooling. The first is the Viipuri Municipal Library (Russia) and the second is the Margaret Esherick House (PA). The commercial code FLUENT is used to perform simulations to study the effect of varying atmospheric conditions and configurations of openings. Three heating simulations for the library showed only small difference in results with atmospheric condition or configuration changes. A colder atmospheric temperature led to colder temperatures in parts of the building. Moving the inlet only slightly changed the temperatures in parts of the building. The cooling simulations for the library had more drastic changes in the openings. All three cases showed the building cooled quickly, but the velocity in the building was above recommended ranges given by ASHRAE Standard 55. Two cooling simulations on the Esherick house differed only by the addition of a solar heat load. The case with the solar heat load showed slightly higher temperatures and less mixing within the house. The final simulation modeled a fire in two fireplaces in the house and showed stratified air with large temperature gradients."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-11132009-150648"],"dc:identifier.uri":["http://hdl.handle.net/10919/35690"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Computational fluid dynamics","natural ventilation"],"dc:title":["Simulation of Airflow and Heat Transfer in Buildings"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:43Z"}