Back to results

Virginia Tech

Implementing Impedance - Based Health Monitoring

Abstract

dc:description.abstract

This work is an experimental study of applying an impedance-based health monitoring technique to complex structures. The work is presented in three parts. In the first part we consider effects of the following three factors on damage detection abilities: actuator excitation level, test wire length and ambient conditions (temperature, structural loading and vibration). It was concluded that increasing the applied voltage improves the signal to noise ratio and damage detection abilities. Test wire lengths under 30m do not affect damage detection abilities. The technique is able to distinguish and detect damage even with variations in temperature, structural loading and vibration. In the second part we apply our health monitoring technique to a complex truss structure and a massive steel steam header. We discovered that with multiplexing (acquiring a single signal from distributed actuators) the actuators on the truss structure we could detect damage but with less location information. Damage detection on the steel pipe ended in inconclusive results. The use of this technique on massive structures needs further investigation. Finally, we conducted a detailed experimental study of monitoring the integrity of composite-reinforced masonry structures. We developed a software package which enables even a casual user to determine if significant damage has occurred in these structures. The technique was successfully applied to detect damage (particularly due to delamination) in these composite-concrete structures. Most significantly, the technique was also able to detect damage well in advance of actual failure. This work relies mainly on frequency response plots and damage metric charts to present the data and to arrive at any conclusions. While frequency response plots give a qualitative approach to the analysis, damage metric charts attempt to quantify the data.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Raju, Vinod
Chair dc:contributor.committeechair
  • Cudney, Harley H.
Committee members dc:contributor.committeemember
  • Lalande, Frederic
  • Duke, John C. Jr.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-111097-14850
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/35657

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Raju, Vinod. Implementing Impedance - Based Health Monitoring. masters thesis, Virginia Tech, 1997. http://hdl.handle.net/10919/35657