{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/35646"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/35646","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A Method for PMU-Based Reconfigurable Monitoring","abstract":"Given an increasing tendency towards distributed generation and alternative energy sources, the power grid must be more carefully monitored in order to ensure stability. Phasor Measurement Units (PMUs) provide very good observation of a small area of a network, but their relatively high cost prevents them from being deployed at every point. Therefore, to monitor an entire network, State Estimation is still required. By combining these two techniques, the accuracy and speed of power network monitoring can be improved. This thesis presents a method for achieving this goal from both hardware and computational perspectives. Practical considerations for PMU placement are discussed, such as instrument transformer calibration, and an algorithm is developed to apply this technique to any power system. The resulting method is termed reconfigurable monitoring - computationally isolated areas which may be grouped as necessary to allow for flexibility in power system monitoring.","abstract_html":"Given an increasing tendency towards distributed generation and alternative energy sources, the power grid must be more carefully monitored in order to ensure stability. Phasor Measurement Units (PMUs) provide very good observation of a small area of a network, but their relatively high cost prevents them from being deployed at every point. Therefore, to monitor an entire network, State Estimation is still required. By combining these two techniques, the accuracy and speed of power network monitoring can be improved. This thesis presents a method for achieving this goal from both hardware and computational perspectives. Practical considerations for PMU placement are discussed, such as instrument transformer calibration, and an algorithm is developed to apply this technique to any power system. The resulting method is termed reconfigurable monitoring - computationally isolated areas which may be grouped as necessary to allow for flexibility in power system monitoring.","abstract_has_math":false,"creators":["Culliss, Jerel Alan"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Centeno, Virgilio A."],"committee_members":["De La Ree, Jaime","Liu, Yilu"],"year":2009,"date_issued":"2009-10-27","date_published":"2009-10-27","updated_at":"2026-07-22T22:19:31Z","subjects":["phasor measurements","PMU","state estimation","reconfigurable monitoring"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11092009-194104"],"render_values":[{"text":"etd-11092009-194104","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/35646","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Centeno, Virgilio A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["De La Ree, Jaime","Liu, Yilu"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Culliss, Jerel Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:47:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:47:41Z","2013-05-20"]},{"key":"dc:date.issued","label":"Date","values":["2009-10-27"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["phasor measurements","PMU","state estimation","reconfigurable monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11092009-194104"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/35646"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Given an increasing tendency towards distributed generation and alternative energy sources, the power grid must be more carefully monitored in order to ensure stability. Phasor Measurement Units (PMUs) provide very good observation of a small area of a network, but their relatively high cost prevents them from being deployed at every point. Therefore, to monitor an entire network, State Estimation is still required. By combining these two techniques, the accuracy and speed of power network monitoring can be improved. This thesis presents a method for achieving this goal from both hardware and computational perspectives. Practical considerations for PMU placement are discussed, such as instrument transformer calibration, and an algorithm is developed to apply this technique to any power system. The resulting method is termed reconfigurable monitoring - computationally isolated areas which may be grouped as necessary to allow for flexibility in power system monitoring."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["A Method for PMU-Based Reconfigurable Monitoring"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Centeno, Virgilio A."],"dc:contributor.committeemember":["De La Ree, Jaime","Liu, Yilu"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Culliss, Jerel Alan"],"dc:date.accessioned":["2014-03-14T20:47:41Z"],"dc:date.available":["2014-03-14T20:47:41Z","2013-05-20"],"dc:date.issued":["2009-10-27"],"dc:description.abstract":["Given an increasing tendency towards distributed generation and alternative energy sources, the power grid must be more carefully monitored in order to ensure stability. Phasor Measurement Units (PMUs) provide very good observation of a small area of a network, but their relatively high cost prevents them from being deployed at every point. Therefore, to monitor an entire network, State Estimation is still required. By combining these two techniques, the accuracy and speed of power network monitoring can be improved. This thesis presents a method for achieving this goal from both hardware and computational perspectives. Practical considerations for PMU placement are discussed, such as instrument transformer calibration, and an algorithm is developed to apply this technique to any power system. The resulting method is termed reconfigurable monitoring - computationally isolated areas which may be grouped as necessary to allow for flexibility in power system monitoring."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-11092009-194104"],"dc:identifier.uri":["http://hdl.handle.net/10919/35646"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["phasor measurements","PMU","state estimation","reconfigurable monitoring"],"dc:title":["A Method for PMU-Based Reconfigurable Monitoring"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:31Z"}