Back to results

Virginia Tech

Mechanical Response Tissue Analysis: Inter- and Intra-trial Reliability in Assessing Bending Stiffness of the Human Tibia in College Aged Women

Abstract

dc:description.abstract

Mechanical Response Tissue Analysis (MRTA) is an emerging technology for assessing maximal bending stiffness (EI) of human long bones in vivo. The MRTA variable, EI, is the product of Young's modulus of elasticity (E) and cross-sectional moment of inertia (I). EI quantifies material and architectural/geometric properties of bone. Published human research using MRTA to measure EI has been limited to the ulna; however, the tibia requires further investigation due to its central involvement in many human activities and exercise-related clinical problems, e.g. stress fracture of the lower leg. To evaluate the inter- and intra-reliability of tibial EI, 22 healthy women (X + SD: 20.8 + 1.8 yr) were assessed twice daily for three non-consecutive days. Each daily session consisted of five repeated trials. The ulnar EI protocol of McCabe et al. [J Bone and Mineral Res. 1991;6(1):53-59] was adapted to assess tibial EI via MRTA. A significant difference was not found in scores for five repeated trials taken consecutively on the same day. Mean scores for EI were higher on day 1 (59.1 &#177; 35.5 N&#183;m<sup>2</sup>, p < 0.05), compared to day 2 (46.9 &#177; 22.3) and day 3 (49.9 &#177; 18.3). Individual trial mean scores for EI on each day (mean of 5 trials) were highly correlated, R<sup>2</sup> = 0.84, 0.62, and 0.79 (set 1 vs. 2, for day 1,2,3, respectively) and the average percent change between sets 1 and 2 on each day was 5.3. The inter-test (between day) reproducibility was found to be low and unacceptable, 11.7, 18.3, and 1.3%, for day 1 vs. 2, 1 vs. 3, and 2 vs. 3. Poor inter-day reliability may be a result of the inability, at the time of this study, to apply the best computational EI model. It is concluded that tibial bone stiffness measurements with the MRTA are in the range of acceptability for same day inter- and intra-trial reliability when the 7-parameter analytic model of vibratory properties developed by McCabe et al. is used.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Human Nutrition, Foods, and Exercise
Department dc:contributor.department
Human Nutrition, Foods, and Exercise
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thorne, Robert
Chair dc:contributor.committeechair
  • Herbert, William G.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-11022000-18330040
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/35568

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Thorne, Robert. Mechanical Response Tissue Analysis: Inter- and Intra-trial Reliability in Assessing Bending Stiffness of the Human Tibia in College Aged Women. masters thesis, Virginia Tech, 2000. http://hdl.handle.net/10919/35568