Abstract
dc:description.abstractAn analytical investigation was conducted to study the behavior of a bottom flange bearing beam-to girder connection subjected to patch loading. This connection would be useful with deep deck (thickness greater than 3 in.) composite slabs as well as with commonly used deck where floor-to-floor height needs to be minimized. Five girder specimens were loaded until yielding during the initial phase of the research. The analysis section consists of the yield line theory and finite element study that were used to develop a model to predict the collapse loads of the girder sections. These results from the model were then compared to the experimental loads. A design procedure utilizing the proposed model and future work recommendations are then presented.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Civil Engineering
- Department dc:contributor.department
- Civil Engineering
- Grantor dc:publisher
- Virginia Tech
- Year dc:date.issued
- 2001
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Lee, Wey-Jen
- Chair dc:contributor.committeechair
-
- Easterling, William Samuel
- Committee members dc:contributor.committeemember
-
- Murray, Thomas M.
- Plaut, Raymond H.
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
Identifiers
dc:identifier.*- Dc Identifier Other
- etd-10302001-095133
- OAI identifier oai:identifier
- oai:vtechworks.lib.vt.edu:10919/35529