{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/35357"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/35357","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Implementation of a Fixed Timing Coupled Inductor Soft-Switching Inverter","abstract":"In research environments, many soft switching inverters have been conceived, simulated, designed, implemented and proven to have advantages over hard switched inverters. To date however, no soft-switching inverters have reached commercial production for various reasons. The fixed timing coupled inductor soft-switching inverter is of interest because in simulation and previous implementation it exhibits load and source adaptability using simple RC timer circuitry and can be implemented with low cost active auxiliary devices. During the course of this implementation, it is noted that attempting to use excessively small/inexpensive active auxiliary devices has reliability ramifications related to device packaging. The issue of auxiliary active device reliability is conjectured upon by referencing available datasheet information, application specific requirements, device pulse testing and secondary research findings related to semiconductor failure characteristics. It is also noted that aspects of the simple fixed timing circuitry operation, in conjunction with coupled inductor and saturable inductor design, can lead to coupled inductor saturation if not properly addressed. Simulation is performed and validates various causes for this non-ideal behavior.","abstract_html":"In research environments, many soft switching inverters have been conceived, simulated, designed, implemented and proven to have advantages over hard switched inverters. To date however, no soft-switching inverters have reached commercial production for various reasons. The fixed timing coupled inductor soft-switching inverter is of interest because in simulation and previous implementation it exhibits load and source adaptability using simple RC timer circuitry and can be implemented with low cost active auxiliary devices. During the course of this implementation, it is noted that attempting to use excessively small/inexpensive active auxiliary devices has reliability ramifications related to device packaging. The issue of auxiliary active device reliability is conjectured upon by referencing available datasheet information, application specific requirements, device pulse testing and secondary research findings related to semiconductor failure characteristics. It is also noted that aspects of the simple fixed timing circuitry operation, in conjunction with coupled inductor and saturable inductor design, can lead to coupled inductor saturation if not properly addressed. Simulation is performed and validates various causes for this non-ideal behavior.","abstract_has_math":false,"creators":["Gouker, Joel Patrick"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Lai, Jih-Sheng"],"committee_members":["De La Ree, Jaime","Ramu, Krishnan"],"year":2007,"date_issued":"2007-09-10","date_published":"2007-09-10","updated_at":"2026-07-22T22:19:03Z","subjects":["fixed timing","soft switching","inverter","coupled inductor"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10112007-110249"],"render_values":[{"text":"etd-10112007-110249","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/35357","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Lai, Jih-Sheng"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["De La Ree, Jaime","Ramu, Krishnan"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Gouker, Joel Patrick"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:46:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:46:35Z","2007-11-02"]},{"key":"dc:date.issued","label":"Date","values":["2007-09-10"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fixed timing","soft switching","inverter","coupled inductor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10112007-110249"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/35357"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In research environments, many soft switching inverters have been conceived, simulated, designed, implemented and proven to have advantages over hard switched inverters. To date however, no soft-switching inverters have reached commercial production for various reasons. The fixed timing coupled inductor soft-switching inverter is of interest because in simulation and previous implementation it exhibits load and source adaptability using simple RC timer circuitry and can be implemented with low cost active auxiliary devices. During the course of this implementation, it is noted that attempting to use excessively small/inexpensive active auxiliary devices has reliability ramifications related to device packaging. The issue of auxiliary active device reliability is conjectured upon by referencing available datasheet information, application specific requirements, device pulse testing and secondary research findings related to semiconductor failure characteristics. It is also noted that aspects of the simple fixed timing circuitry operation, in conjunction with coupled inductor and saturable inductor design, can lead to coupled inductor saturation if not properly addressed. Simulation is performed and validates various causes for this non-ideal behavior."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Implementation of a Fixed Timing Coupled Inductor Soft-Switching Inverter"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Lai, Jih-Sheng"],"dc:contributor.committeemember":["De La Ree, Jaime","Ramu, Krishnan"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Gouker, Joel Patrick"],"dc:date.accessioned":["2014-03-14T20:46:35Z"],"dc:date.available":["2014-03-14T20:46:35Z","2007-11-02"],"dc:date.issued":["2007-09-10"],"dc:description.abstract":["In research environments, many soft switching inverters have been conceived, simulated, designed, implemented and proven to have advantages over hard switched inverters. To date however, no soft-switching inverters have reached commercial production for various reasons. The fixed timing coupled inductor soft-switching inverter is of interest because in simulation and previous implementation it exhibits load and source adaptability using simple RC timer circuitry and can be implemented with low cost active auxiliary devices. During the course of this implementation, it is noted that attempting to use excessively small/inexpensive active auxiliary devices has reliability ramifications related to device packaging. The issue of auxiliary active device reliability is conjectured upon by referencing available datasheet information, application specific requirements, device pulse testing and secondary research findings related to semiconductor failure characteristics. It is also noted that aspects of the simple fixed timing circuitry operation, in conjunction with coupled inductor and saturable inductor design, can lead to coupled inductor saturation if not properly addressed. Simulation is performed and validates various causes for this non-ideal behavior."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-10112007-110249"],"dc:identifier.uri":["http://hdl.handle.net/10919/35357"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["fixed timing","soft switching","inverter","coupled inductor"],"dc:title":["Implementation of a Fixed Timing Coupled Inductor Soft-Switching Inverter"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:03Z"}