Back to results

Virginia Tech

Assessment of Intrinsic Bioremediation at a PCE Contaminated Site

Abstract

dc:description.abstract

Groundwater parameter analysis, microcosm experiments, and microcosms modeling were undertaken to assess the potential of Monitored Natural Attenuation as a remediation strategy at Site 12 at the Naval Amphibious Base (NAB) Little Creek. Site 12 was contaminated with PCE waste disposed by a former dry cleaning facility. In the groundwater analysis, contaminant characteristics and redox indicators were evaluated to assess the reductive dechlorination potential of Site 12. The results of the groundwater analysis indicated that Site 12 exhibited sulfate-reducing and methanogenic conditions which provide the required environment for reductive dechlorination. However, Site 12 only demonstrated partial reductive dechlorination to cis-1,2-DCE and possible anaerobic oxidation of cis-1,2-DCE and VC to CO₂. Microcosms were designed to further evaluate the extent of microbial degradation of the chlorinated ethenes at Site 12 and to provide concentration versus time data for the estimation of chlorinated ethenes' biodegradation rates. The extent of degradation in the microcosms was consistent with the groundwater data. However, ethene production was not observed and the quantity of TCE measured for two of the microcosms differed substantially when compared to the groundwater data. The microcosm model used SEAM3D to simulate the results of the microcosm experiments (concentration versus time data) to estimate the biodegradation rates of PCE and its daughter products. The SEAM3D reductive dechlorination package, based on Monod kinetics, predicted for the MLS12-Shallow microcosm maximum specific utilization rates for PCE, TCE, cis-1,2-DCE and VC at 0.4, 0.42, 0.05, and 0.25 day⁻¹, respectively and half saturation coefficients for PCE, TCE, cis-1,2-DCE and VC at 0.41, 0.01, 0.07, and 0.02 mg/L, respectively. The results of this study suggest that while the groundwater environment provides the necessary conditions for reductive dechlorination, Site 12 is not an efficient system for reductive dechlorination. This lack of efficiency may stem from sparse microbial populations capable of reducing cis-1,2-DCE or the system may contain levels of PCE which inhibit the further reduction of cis-1,2-DCE. Based on the observed inhibitory relationship between PCE and cis-1,2-DCE and VC production, source removal would reduce the PCE levels and encourage further reductive dechlorination at Site 12. Therefore, the recommended first step for a monitered natural attenuation-based remediation strategy at Site 12 should be source removal.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rectanus, Heather Veith
Chairs dc:contributor.committeechair
  • Widdowson, Mark A.
  • Novak, John T.
Committee member dc:contributor.committeemember
  • Berry, Duane F.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-10092000-15360015
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/35335

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Rectanus, Heather Veith. Assessment of Intrinsic Bioremediation at a PCE Contaminated Site. masters thesis, Virginia Tech, 2000. http://hdl.handle.net/10919/35335