{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/35143"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/35143","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Full Brain Blood-Oxygen-Level-Dependent Signal Parameter Estimation Using Particle Filters","abstract":"Traditional methods of analyzing functional Magnetic Resonance Images use a linear combination of just a few static regressors. This work demonstrates an alternative approach using a physiologically inspired nonlinear model. By using a particle filter to optimize the model parameters, the computation time is kept below a minute per voxel without requiring a linearization of the noise in the state variables. The activation results show regions similar to those found in Statistical Parametric Mapping; however, there are some notable regions not detected by that technique. Though the parameters selected by the particle filter based approach are more than sufficient to predict the Blood-Oxygen-Level-Dependent signal response, more model constraints are needed to uniquely identify a single set of parameters. This illposed nature explains the large discrepancies found in other research that attempted to characterize the model parameters. For this reason the final distribution of parameters is more medically relevant than a single estimate. Because the output of the particle filter is a full posterior probability, the reliance on the mean to estimate parameters is unnecessary. This work presents not just a viable alternative to the traditional method of detecting activation, but an extensible technique of estimating the joint probability distribution function of the Blood-Oxygen-Level-Dependent Signal parameters.","abstract_html":"Traditional methods of analyzing functional Magnetic Resonance Images use a linear combination of just a few static regressors. This work demonstrates an alternative approach using a physiologically inspired nonlinear model. By using a particle filter to optimize the model parameters, the computation time is kept below a minute per voxel without requiring a linearization of the noise in the state variables. The activation results show regions similar to those found in Statistical Parametric Mapping; however, there are some notable regions not detected by that technique. Though the parameters selected by the particle filter based approach are more than sufficient to predict the Blood-Oxygen-Level-Dependent signal response, more model constraints are needed to uniquely identify a single set of parameters. This illposed nature explains the large discrepancies found in other research that attempted to characterize the model parameters. For this reason the final distribution of parameters is more medically relevant than a single estimate. Because the output of the particle filter is a full posterior probability, the reliance on the mean to estimate parameters is unnecessary. This work presents not just a viable alternative to the traditional method of detecting activation, but an extensible technique of estimating the joint probability distribution function of the Blood-Oxygen-Level-Dependent Signal parameters.","abstract_has_math":false,"creators":["Chambers, Micah Christopher"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Wyatt, Christopher L."],"committee_members":["Baumann, William T.","Beex, A. A. Louis","Stilwell, Daniel J."],"year":2010,"date_issued":"2010-09-14","date_published":"2010-09-14","updated_at":"2026-07-22T22:19:48Z","subjects":["BOLD Response","FMRI","Nonlinear Systems","Particle Filter","Bayesian Statistics","System Identification"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-09212010-215625"],"render_values":[{"text":"etd-09212010-215625","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/35143","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Wyatt, Christopher L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Baumann, William T.","Beex, A. A. Louis","Stilwell, Daniel J."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Chambers, Micah Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:45:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:45:46Z","2011-01-05"]},{"key":"dc:date.issued","label":"Date","values":["2010-09-14"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["BOLD Response","FMRI","Nonlinear Systems","Particle Filter","Bayesian Statistics","System Identification"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-09212010-215625"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/35143"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Traditional methods of analyzing functional Magnetic Resonance Images use a linear combination of just a few static regressors. This work demonstrates an alternative approach using a physiologically inspired nonlinear model. By using a particle filter to optimize the model parameters, the computation time is kept below a minute per voxel without requiring a linearization of the noise in the state variables. The activation results show regions similar to those found in Statistical Parametric Mapping; however, there are some notable regions not detected by that technique. Though the parameters selected by the particle filter based approach are more than sufficient to predict the Blood-Oxygen-Level-Dependent signal response, more model constraints are needed to uniquely identify a single set of parameters. This illposed nature explains the large discrepancies found in other research that attempted to characterize the model parameters. For this reason the final distribution of parameters is more medically relevant than a single estimate. Because the output of the particle filter is a full posterior probability, the reliance on the mean to estimate parameters is unnecessary. This work presents not just a viable alternative to the traditional method of detecting activation, but an extensible technique of estimating the joint probability distribution function of the Blood-Oxygen-Level-Dependent Signal parameters."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Full Brain Blood-Oxygen-Level-Dependent Signal Parameter Estimation Using Particle Filters"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Wyatt, Christopher L."],"dc:contributor.committeemember":["Baumann, William T.","Beex, A. A. Louis","Stilwell, Daniel J."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Chambers, Micah Christopher"],"dc:date.accessioned":["2014-03-14T20:45:46Z"],"dc:date.available":["2014-03-14T20:45:46Z","2011-01-05"],"dc:date.issued":["2010-09-14"],"dc:description.abstract":["Traditional methods of analyzing functional Magnetic Resonance Images use a linear combination of just a few static regressors. This work demonstrates an alternative approach using a physiologically inspired nonlinear model. By using a particle filter to optimize the model parameters, the computation time is kept below a minute per voxel without requiring a linearization of the noise in the state variables. The activation results show regions similar to those found in Statistical Parametric Mapping; however, there are some notable regions not detected by that technique. Though the parameters selected by the particle filter based approach are more than sufficient to predict the Blood-Oxygen-Level-Dependent signal response, more model constraints are needed to uniquely identify a single set of parameters. This illposed nature explains the large discrepancies found in other research that attempted to characterize the model parameters. For this reason the final distribution of parameters is more medically relevant than a single estimate. Because the output of the particle filter is a full posterior probability, the reliance on the mean to estimate parameters is unnecessary. This work presents not just a viable alternative to the traditional method of detecting activation, but an extensible technique of estimating the joint probability distribution function of the Blood-Oxygen-Level-Dependent Signal parameters."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-09212010-215625"],"dc:identifier.uri":["http://hdl.handle.net/10919/35143"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["BOLD Response","FMRI","Nonlinear Systems","Particle Filter","Bayesian Statistics","System Identification"],"dc:title":["Full Brain Blood-Oxygen-Level-Dependent Signal Parameter Estimation Using Particle Filters"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:48Z"}