Back to results

Virginia Tech

Design and Development of a Squeeze-Mode Rheometer for Evaluating Magneto-Rheological Fluids

Abstract

dc:description.abstract

This study aims to better understand the behavior of magnetorheological (MR) fluids operated in the non-conventional squeeze mode through the use of a custom designed rheometer. Squeeze mode is the least understood of the three operational modes of MR fluid and thus its potential has yet to be realized in practical applications. By identifying the behavior of MR fluid in this mode, the foundation for future development of MR technology will be laid. Using the limited amount of literature available on squeeze-mode operation in conjunction with conventional principles associated with MR technology, a custom rheometer was designed and fabricated. A detailed account of the design considerations and background information on the fundamentals incorporated into the design are provided. The squeeze-mode rheometer was used to evaluate a variety of MR fluids to observe trends that may exist across fluids. Specifically, fluids of different ferrous particle volume fractions were considered. Through testing, common trends in fluid stiffness were observed for multiple fluids tested with the squeeze-mode rheometer. When operated in squeeze mode, activated MR fluid has shown to provide substantial resistance to compressive loading, possibly making it attractive for low-displacement high-load systems. The primary observation from the tests is that the activated fluid's stiffness progressively increases over the duration of fluid operation. This phenomenon is due to severe carrier-fluid separation coupled with the formation of ferrous particle aggregate clumps in the fluid. This effect is further explored in this research.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cavey, Ryan Hale
Chair dc:contributor.committeechair
  • Ahmadian, Mehdi
Committee members dc:contributor.committeemember
  • Sandu, Corina
  • West, Robert L. Jr.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-09212008-013322
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/35139

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Cavey, Ryan Hale. Design and Development of a Squeeze-Mode Rheometer for Evaluating Magneto-Rheological Fluids. masters thesis, Virginia Tech, 2008. http://hdl.handle.net/10919/35139