Back to results

Virginia Tech

Sequential Electron Acceptor Model of Intrinsic Bioremediation at a BTEX Contaminated LUST Site in Laurel Bay, South Carolina

Abstract

dc:description.abstract

Contaminant transport modeling is being used more often at petroleum hydrocarbon contaminated sites in an attempt to aid engineers in evaluating the feasibility of natural attenuation as a remediation alternative in groundwater systems. In this research, a three-dimensional sequential electron acceptor computer model, SEAM3D, developed by Waddill and Widdowson (1997) was used to simulate contaminant transport at a leaking underground storage tank site in Beaufort, South Carolina. Gasoline containing benzene, toluene, ethylbenzene, and xylene (BTEX) as well as methyl tertiary butyl ether (MTBE) leaked into the subsurface at the site late in 1990, and monitoring of the water table elevations and contaminant concentrations began in 1993. Using the field data, the groundwater flow model MODFLOW was used to develop and calibrate a flow model for the Laurel Bay site using GMS (Groundwater Modeling System) v2.1. MODFLOW was coupled with the SEAM3D contaminant transport model, and the available concentration levels were used to calibrate, verify, and validate the site model. The results indicated that SEAM3D simulated complex, interconnected processes including biodegradation, and the transport of multiple hydrocarbon compounds, electron acceptors, and end products over time and space at a specific petroleum hydrocarbon contaminated site. Once the model was calibrated and verified, the model output was used to study the changes in contaminant mass distribution, contaminant mass loss, and mass loss rates for each terminal electron accepting process (TEAP) over time. It was found that the natural attenuation capacity of the aquifer was insufficient to stabilize the plume and prevent it from reaching the defined point of contact (POC). Contamination was shown to have reached the POC by 1994, just four years into the simulation. Results indicated that despite oxygen limitation within the BTEX plume, aerobic biodegradation was responsible for the greatest amount of mass loss, close to 70 %, relative to the sum of the anaerobic processes after 20 years.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1999

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lade, Nancy
Chair dc:contributor.committeechair
  • Widdowson, Mark A.
Committee members dc:contributor.committeemember
  • Diplas, Panayiotis
  • Novak, John T.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-091099-202753
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/35009

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Lade, Nancy. Sequential Electron Acceptor Model of Intrinsic Bioremediation at a BTEX Contaminated LUST Site in Laurel Bay, South Carolina. masters thesis, Virginia Tech, 1999. http://hdl.handle.net/10919/35009