Back to results

Virginia Tech

Design of a Cyclic Sliding, Dynamically Loaded Wear Testing Device for the Evaluation of Total Knee Replacement Materials

Abstract

dc:description.abstract

During normal walking, the relative motion of the human knee involves flexion/extension, anterior/posterior sliding, and medial/lateral rotation. As well, the knee experiences a complex, dynamic loading curve with a peak of up to seven times body weight. However, most wear testing machines that have been used to evaluate total knee replacement materials are unidirectional and/or apply only static force. This thesis presents an alternate wear testing device capable of simulating the most prevalent motions of the knee, and applying physiologically-correct loading to the material interface. By incorporating a CoCr disc, an UHMWPE block, stepping motors, pneumatic components, computer control, and linear tables in an x-y configuration, the device is capable of quickly screening new and alternative materials to UHMWPE before evaluating them on a much more expensive knee simulator. In addition, flexibility of the device allows programming of many different motion and loading configurations permitting materials testing under only certain circumstances, or evaluating the effects on wear of specific motions. Design rationale, development, validation, and future recommendations are presented.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thompson, Matthew Thomas
Chairs dc:contributor.committeechair
  • Reinholtz, Charles F.
  • Foy, Jonette Rogers
Committee member dc:contributor.committeemember
  • Robertshaw, Harry H.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-08062001-153737
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/34371

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Thompson, Matthew Thomas. Design of a Cyclic Sliding, Dynamically Loaded Wear Testing Device for the Evaluation of Total Knee Replacement Materials. masters thesis, Virginia Tech, 2001. http://hdl.handle.net/10919/34371