{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/33833"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/33833","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Magnetic Resonance Imaging of the Normal Equine Larynx","abstract":"A study was performed to establish the appearance of normal equine laryngeal cartilages using magnetic resonance imaging. Specimens were acquired from clinically normal horses that were euthanized for reasons other than respiratory disease. Three in situ and 5 ex vivo larynges were imaged using a 0.3 Tesla system. Images were obtained in the transverse plane using T1-weighted 3D spin echo, T2-weighted 3D spin echo, T2-weighted gradient echo, short tau inversion recovery (STIR), and proton density spin echo sequences. Five ex vivo larynges were also imaged in the transverse plane using a 1.5 Tesla system, sequences included T1-weighted 3D spin echo, T2-weighted 3D turbo-spin echo, turbo inversion recovery (TIRM), and proton density spin echo sequences. A frozen gross laryngeal specimen was sliced in 5-mm transverse sections for comparison to the MR images. Excellent correlation was found between MR images and the gross transverse sections. Successful imaging was accomplished using both imaging systems; however, the 1.5 Tesla system yielded superior image resolution. The 0.3 Tesla imaging system would accommodate the intact equine head, which was not possible using the 1.5 Tesla MRI system. The internal morphology of the laryngeal cartilages was clearly identified in all imaging sequences obtained. Cartilages were found to differ in signal intensity based on the tissue composition and imaging sequences performed. MRI was determined to be a useful imaging modality for evaluating the cartilage morphology of the equine larynx. Further investigation is required to document pathologic morphology.","abstract_html":"A study was performed to establish the appearance of normal equine laryngeal cartilages using magnetic resonance imaging. Specimens were acquired from clinically normal horses that were euthanized for reasons other than respiratory disease. Three in situ and 5 ex vivo larynges were imaged using a 0.3 Tesla system. Images were obtained in the transverse plane using T1-weighted 3D spin echo, T2-weighted 3D spin echo, T2-weighted gradient echo, short tau inversion recovery (STIR), and proton density spin echo sequences. Five ex vivo larynges were also imaged in the transverse plane using a 1.5 Tesla system, sequences included T1-weighted 3D spin echo, T2-weighted 3D turbo-spin echo, turbo inversion recovery (TIRM), and proton density spin echo sequences. A frozen gross laryngeal specimen was sliced in 5-mm transverse sections for comparison to the MR images. Excellent correlation was found between MR images and the gross transverse sections. Successful imaging was accomplished using both imaging systems; however, the 1.5 Tesla system yielded superior image resolution. The 0.3 Tesla imaging system would accommodate the intact equine head, which was not possible using the 1.5 Tesla MRI system. The internal morphology of the laryngeal cartilages was clearly identified in all imaging sequences obtained. Cartilages were found to differ in signal intensity based on the tissue composition and imaging sequences performed. MRI was determined to be a useful imaging modality for evaluating the cartilage morphology of the equine larynx. Further investigation is required to document pathologic morphology.","abstract_has_math":false,"creators":["Henderson, Cortney Erik"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical and Veterinary Sciences","degree_department":"Biomedical and Veterinary Sciences","school":null,"contributors":[],"advisors":[],"committee_chairs":["Sullins, Kenneth E."],"committee_members":["Phillips, C. Douglas","McCutcheon, L. Jill","White, Nathaniel A. II"],"year":2006,"date_issued":"2006-06-22","date_published":"2006-06-22","updated_at":"2026-07-22T22:20:20Z","subjects":["magnetic resonance imaging","larynx","Horses","MRI","respiratory"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06302006-005527"],"render_values":[{"text":"etd-06302006-005527","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/33833","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Sullins, Kenneth E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Phillips, C. Douglas","McCutcheon, L. Jill","White, Nathaniel A. II"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical and Veterinary Sciences"]},{"key":"dc:creator","label":"Author","values":["Henderson, Cortney Erik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:40:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:40:54Z","2006-09-19"]},{"key":"dc:date.issued","label":"Date","values":["2006-06-22"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical and Veterinary Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["magnetic resonance imaging","larynx","Horses","MRI","respiratory"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06302006-005527"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/33833"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A study was performed to establish the appearance of normal equine laryngeal cartilages using magnetic resonance imaging. Specimens were acquired from clinically normal horses that were euthanized for reasons other than respiratory disease. Three in situ and 5 ex vivo larynges were imaged using a 0.3 Tesla system. Images were obtained in the transverse plane using T1-weighted 3D spin echo, T2-weighted 3D spin echo, T2-weighted gradient echo, short tau inversion recovery (STIR), and proton density spin echo sequences. Five ex vivo larynges were also imaged in the transverse plane using a 1.5 Tesla system, sequences included T1-weighted 3D spin echo, T2-weighted 3D turbo-spin echo, turbo inversion recovery (TIRM), and proton density spin echo sequences. A frozen gross laryngeal specimen was sliced in 5-mm transverse sections for comparison to the MR images. Excellent correlation was found between MR images and the gross transverse sections. Successful imaging was accomplished using both imaging systems; however, the 1.5 Tesla system yielded superior image resolution. The 0.3 Tesla imaging system would accommodate the intact equine head, which was not possible using the 1.5 Tesla MRI system. The internal morphology of the laryngeal cartilages was clearly identified in all imaging sequences obtained. Cartilages were found to differ in signal intensity based on the tissue composition and imaging sequences performed. MRI was determined to be a useful imaging modality for evaluating the cartilage morphology of the equine larynx. Further investigation is required to document pathologic morphology."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Magnetic Resonance Imaging of the Normal Equine Larynx"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Sullins, Kenneth E."],"dc:contributor.committeemember":["Phillips, C. Douglas","McCutcheon, L. Jill","White, Nathaniel A. II"],"dc:contributor.department":["Biomedical and Veterinary Sciences"],"dc:creator":["Henderson, Cortney Erik"],"dc:date.accessioned":["2014-03-14T20:40:54Z"],"dc:date.available":["2014-03-14T20:40:54Z","2006-09-19"],"dc:date.issued":["2006-06-22"],"dc:description.abstract":["A study was performed to establish the appearance of normal equine laryngeal cartilages using magnetic resonance imaging. Specimens were acquired from clinically normal horses that were euthanized for reasons other than respiratory disease. Three in situ and 5 ex vivo larynges were imaged using a 0.3 Tesla system. Images were obtained in the transverse plane using T1-weighted 3D spin echo, T2-weighted 3D spin echo, T2-weighted gradient echo, short tau inversion recovery (STIR), and proton density spin echo sequences. Five ex vivo larynges were also imaged in the transverse plane using a 1.5 Tesla system, sequences included T1-weighted 3D spin echo, T2-weighted 3D turbo-spin echo, turbo inversion recovery (TIRM), and proton density spin echo sequences. A frozen gross laryngeal specimen was sliced in 5-mm transverse sections for comparison to the MR images. Excellent correlation was found between MR images and the gross transverse sections. Successful imaging was accomplished using both imaging systems; however, the 1.5 Tesla system yielded superior image resolution. The 0.3 Tesla imaging system would accommodate the intact equine head, which was not possible using the 1.5 Tesla MRI system. The internal morphology of the laryngeal cartilages was clearly identified in all imaging sequences obtained. Cartilages were found to differ in signal intensity based on the tissue composition and imaging sequences performed. MRI was determined to be a useful imaging modality for evaluating the cartilage morphology of the equine larynx. Further investigation is required to document pathologic morphology."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-06302006-005527"],"dc:identifier.uri":["http://hdl.handle.net/10919/33833"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["magnetic resonance imaging","larynx","Horses","MRI","respiratory"],"dc:title":["Magnetic Resonance Imaging of the Normal Equine Larynx"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical and Veterinary Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:20Z"}