Back to results

Virginia Tech

Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible

Abstract

dc:description.abstract

Bilateral mandibular ostectomies were performed between premolars 3 and 4 in 10 adult canine specimens. A type I external fixator incorporating a full interdental pin was placed stabilizing a 0.5 cm fracture gap. Four different pin configurations were tested in dorsoventral bending five separate times on each of the ten mandibles: 1) intact mandibular bodies with fixator; 2) ostectomized mandibular bodies and complete fixator; 3) ostectomized mandibular bodies with the caudal pins of the rostral fragment cut; 4) ostectomized mandibular bodies with all pins of the rostral fragment cut. The full interdental pin remained intact in all configurations. Total stiffness and gap stiffness were then determined for each fixation geometry on a materials testing machine. The mean total stiffness(Nm/rads) for the four configurations was 1) 1543.6, 2) 301.6, 3) 290.5, 4) 267.0. The mean gap stiffness(Nm/rads) for the right hemimandible was: 2) 2041.1, 3) 1763.5, 4) 1679.9. The mean gap stiffness of the left hemimandible was: 2) 2110.8, 3)1880.1, 4)1861.1. There was no gap stiffness for the first configuration since a fracture gap was not present. Two-way ANOVA was performed on the gap stiffness and the total stiffness. There was a significant decrease in total stiffness between intact mandibles and ostectomized mandibles regardless of external fixator configuration. However, there was not a significant difference in total stiffness or gap stiffness among the different external fixator configurations applied to ostectomized mandible. External fixator configurations with only the full interdental pin engaging the rostral fragment were as stiff as configurations which had two or four additional pins in the rostral fragment for the applied loads. External fixators for rostral mandibular fractures may be rigidly secured with rostral fragment implants applied extracortically avoiding iatrogenic trauma to teeth and tooth roots.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Veterinary Medical Sciences
Department dc:contributor.department
Veterinary Medical Sciences
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cook, Wesley Todd
Chair dc:contributor.committeechair
  • Smith, Mark M.
Committee members dc:contributor.committeemember
  • Shires, Peter K.
  • Markel, Mark
  • Grant, John Wallace

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-06222000-22500037
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/33683

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Cook, Wesley Todd. Ex Vivo Biomechanics of a Bilateral Type I/Bilateral Interdental Pin and Acrylic External Fixator Applied to the Canine Mandible. masters thesis, Virginia Tech, 2000. http://hdl.handle.net/10919/33683