{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/33526"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/33526","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Investigation of several aspects of the vibration characteristics of steel member-supported floors","abstract":"Four aspects influencing the vibration characteristics of steel member supported floors were investigated. The four aspects are: 1) the number of tee-beams effective in resisting a heel-drop impact for steel joist and steel beam-concrete slab floors, 2) the effective moment of inertia of steel joist and joist-girder members, 3) the ability of joist seats to provide composite behavior between the supporting member and overlying slab, and 4) the effects of extending and restraining the bottom chords of joist members. A new equation was developed to predict the number of effective tee-beams. The proposed equation is recommended to replace the two current equations. The proposed equation is a regression equation based on the results of a finite element analysis of 240 floor systems and is considered to be more accurate than the current equations. Next, a study was undertaken to determine the relationship between the span-to depth ratio of a joist or joist-girder member and it's effective moment of inertia. Twenty five joists and joist-girders were modeled and analyzed using the finite element method and their effective stiffnesses calculated. The effective stiffness of each member was plotted against the respective span-to-depth ratio. A linear regression line was then fit to the data to mathematically represent the trend. Finally, a vibration test floor was constructed to investigate the joist seat behavior and extended bottom chords. Finite element models were developed and analyzed and frequency and stiffness tests were performed to evaluate the floor's behavior. Conclusions were then drawn and recommendations made concerning the joist seat behavior and the effects of extending joist bottom chords.","abstract_html":"Four aspects influencing the vibration characteristics of steel member supported floors were investigated. The four aspects are: 1) the number of tee-beams effective in resisting a heel-drop impact for steel joist and steel beam-concrete slab floors, 2) the effective moment of inertia of steel joist and joist-girder members, 3) the ability of joist seats to provide composite behavior between the supporting member and overlying slab, and 4) the effects of extending and restraining the bottom chords of joist members. A new equation was developed to predict the number of effective tee-beams. The proposed equation is recommended to replace the two current equations. The proposed equation is a regression equation based on the results of a finite element analysis of 240 floor systems and is considered to be more accurate than the current equations. Next, a study was undertaken to determine the relationship between the span-to depth ratio of a joist or joist-girder member and it&#x27;s effective moment of inertia. Twenty five joists and joist-girders were modeled and analyzed using the finite element method and their effective stiffnesses calculated. The effective stiffness of each member was plotted against the respective span-to-depth ratio. A linear regression line was then fit to the data to mathematically represent the trend. Finally, a vibration test floor was constructed to investigate the joist seat behavior and extended bottom chords. Finite element models were developed and analyzed and frequency and stiffness tests were performed to evaluate the floor&#x27;s behavior. Conclusions were then drawn and recommendations made concerning the joist seat behavior and the effects of extending joist bottom chords.","abstract_has_math":false,"creators":["Kitterman, Stephen S."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Murray, Thomas M."],"committee_members":["Easterling, William Samuel","Plaut, Raymond H."],"year":1994,"date_issued":"1994-09-15","date_published":"1994-09-15","updated_at":"2026-07-22T22:20:41Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063528"],"render_values":[{"text":"etd-06112009-063528","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/33526","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Murray, Thomas M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Easterling, William Samuel","Plaut, Raymond H."]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Kitterman, Stephen S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:39:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:39:49Z","2013-05-28"]},{"key":"dc:date.issued","label":"Date","values":["1994-09-15"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063528"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/33526"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Four aspects influencing the vibration characteristics of steel member supported floors were investigated. The four aspects are: 1) the number of tee-beams effective in resisting a heel-drop impact for steel joist and steel beam-concrete slab floors, 2) the effective moment of inertia of steel joist and joist-girder members, 3) the ability of joist seats to provide composite behavior between the supporting member and overlying slab, and 4) the effects of extending and restraining the bottom chords of joist members. A new equation was developed to predict the number of effective tee-beams. The proposed equation is recommended to replace the two current equations. The proposed equation is a regression equation based on the results of a finite element analysis of 240 floor systems and is considered to be more accurate than the current equations. Next, a study was undertaken to determine the relationship between the span-to depth ratio of a joist or joist-girder member and it's effective moment of inertia. Twenty five joists and joist-girders were modeled and analyzed using the finite element method and their effective stiffnesses calculated. The effective stiffness of each member was plotted against the respective span-to-depth ratio. A linear regression line was then fit to the data to mathematically represent the trend. Finally, a vibration test floor was constructed to investigate the joist seat behavior and extended bottom chords. Finite element models were developed and analyzed and frequency and stiffness tests were performed to evaluate the floor's behavior. Conclusions were then drawn and recommendations made concerning the joist seat behavior and the effects of extending joist bottom chords."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Investigation of several aspects of the vibration characteristics of steel member-supported floors"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Murray, Thomas M."],"dc:contributor.committeemember":["Easterling, William Samuel","Plaut, Raymond H."],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Kitterman, Stephen S."],"dc:date.accessioned":["2014-03-14T20:39:49Z"],"dc:date.available":["2014-03-14T20:39:49Z","2013-05-28"],"dc:date.issued":["1994-09-15"],"dc:description.abstract":["Four aspects influencing the vibration characteristics of steel member supported floors were investigated. The four aspects are: 1) the number of tee-beams effective in resisting a heel-drop impact for steel joist and steel beam-concrete slab floors, 2) the effective moment of inertia of steel joist and joist-girder members, 3) the ability of joist seats to provide composite behavior between the supporting member and overlying slab, and 4) the effects of extending and restraining the bottom chords of joist members. A new equation was developed to predict the number of effective tee-beams. The proposed equation is recommended to replace the two current equations. The proposed equation is a regression equation based on the results of a finite element analysis of 240 floor systems and is considered to be more accurate than the current equations. Next, a study was undertaken to determine the relationship between the span-to depth ratio of a joist or joist-girder member and it's effective moment of inertia. Twenty five joists and joist-girders were modeled and analyzed using the finite element method and their effective stiffnesses calculated. The effective stiffness of each member was plotted against the respective span-to-depth ratio. A linear regression line was then fit to the data to mathematically represent the trend. Finally, a vibration test floor was constructed to investigate the joist seat behavior and extended bottom chords. Finite element models were developed and analyzed and frequency and stiffness tests were performed to evaluate the floor's behavior. Conclusions were then drawn and recommendations made concerning the joist seat behavior and the effects of extending joist bottom chords."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06112009-063528"],"dc:identifier.uri":["http://hdl.handle.net/10919/33526"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Investigation of several aspects of the vibration characteristics of steel member-supported floors"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:41Z"}