{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/33524"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/33524","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Ultimate strength analysis of partially composite and fully composite open-web steel joists","abstract":"The behavior of composite steel joists with various degrees of shear connection is investigated. The results of eight full-size composite joist tests, conducted as a portion of the study, are presented. Joist spans range from 24 ft. to 30 ft. and depths from 8 in. to 18 in. Six types of mechanical connectors provide horizontal shear transfer capacity. Steel deck supported slabs, from 3 in. to 4 in. thick, are used for all tests. The results of the experiments are used to evaluate the flexural strength and associated failure modes of partially composite and fully composite joists. The results of each test are compared to theoretical calculations based on an ultimate strength flexural model. The joists are classified by how the provided amount of shear connection compares to the bottom chord yield force and by how the provided amount of shear connection in conjunction with the top chord capacity compares to the bottom chord yield force. Behavior typical of each classification is discussed. Correlation with previously conducted composite joist tests of similar configuration is also discussed.","abstract_html":"The behavior of composite steel joists with various degrees of shear connection is investigated. The results of eight full-size composite joist tests, conducted as a portion of the study, are presented. Joist spans range from 24 ft. to 30 ft. and depths from 8 in. to 18 in. Six types of mechanical connectors provide horizontal shear transfer capacity. Steel deck supported slabs, from 3 in. to 4 in. thick, are used for all tests. The results of the experiments are used to evaluate the flexural strength and associated failure modes of partially composite and fully composite joists. The results of each test are compared to theoretical calculations based on an ultimate strength flexural model. The joists are classified by how the provided amount of shear connection compares to the bottom chord yield force and by how the provided amount of shear connection in conjunction with the top chord capacity compares to the bottom chord yield force. Behavior typical of each classification is discussed. Correlation with previously conducted composite joist tests of similar configuration is also discussed.","abstract_has_math":false,"creators":["Lauer, Douglas F."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994-10-05","date_published":"1994-10-05","updated_at":"2026-07-22T22:19:38Z","subjects":["composite joist tests"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063330"],"render_values":[{"text":"etd-06112009-063330","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/33524","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Lauer, Douglas F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:39:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:39:49Z","2009-06-11"]},{"key":"dc:date.issued","label":"Date","values":["1994-10-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["composite joist tests"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063330"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/33524"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The behavior of composite steel joists with various degrees of shear connection is investigated. The results of eight full-size composite joist tests, conducted as a portion of the study, are presented. Joist spans range from 24 ft. to 30 ft. and depths from 8 in. to 18 in. Six types of mechanical connectors provide horizontal shear transfer capacity. Steel deck supported slabs, from 3 in. to 4 in. thick, are used for all tests. The results of the experiments are used to evaluate the flexural strength and associated failure modes of partially composite and fully composite joists. The results of each test are compared to theoretical calculations based on an ultimate strength flexural model. The joists are classified by how the provided amount of shear connection compares to the bottom chord yield force and by how the provided amount of shear connection in conjunction with the top chord capacity compares to the bottom chord yield force. Behavior typical of each classification is discussed. Correlation with previously conducted composite joist tests of similar configuration is also discussed."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Ultimate strength analysis of partially composite and fully composite open-web steel joists"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Lauer, Douglas F."],"dc:date.accessioned":["2014-03-14T20:39:49Z"],"dc:date.available":["2014-03-14T20:39:49Z","2009-06-11"],"dc:date.issued":["1994-10-05"],"dc:description.abstract":["The behavior of composite steel joists with various degrees of shear connection is investigated. The results of eight full-size composite joist tests, conducted as a portion of the study, are presented. Joist spans range from 24 ft. to 30 ft. and depths from 8 in. to 18 in. Six types of mechanical connectors provide horizontal shear transfer capacity. Steel deck supported slabs, from 3 in. to 4 in. thick, are used for all tests. The results of the experiments are used to evaluate the flexural strength and associated failure modes of partially composite and fully composite joists. The results of each test are compared to theoretical calculations based on an ultimate strength flexural model. The joists are classified by how the provided amount of shear connection compares to the bottom chord yield force and by how the provided amount of shear connection in conjunction with the top chord capacity compares to the bottom chord yield force. Behavior typical of each classification is discussed. Correlation with previously conducted composite joist tests of similar configuration is also discussed."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06112009-063330"],"dc:identifier.uri":["http://hdl.handle.net/10919/33524"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["composite joist tests"],"dc:title":["Ultimate strength analysis of partially composite and fully composite open-web steel joists"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:38Z"}