{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/32121"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/32121","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The Advancement of Adaptive Relaying in Power Systems Protection","abstract":"The electrical distribution system in the United States is considered one of the most complicated machines in existence. Electrical phenomena in such a complex system can inflict serious self-harm. This requires damage prevention from protection schemes. Until recently, there was a safe gap between capacity to deliver power and the demand. Therefore, these protection schemes focused on dependability allowing the disconnection of lines, transformers, or other devices with the purpose of isolating the faulted element. On some occasions, the disconnections made were not necessary. The other extreme of reliability calls for security. This aspect of reliability calls for the operation of the protective devices only for faults within the intended area of protection. There is a tradeoff here; where a dependable protection scheme will assuredly prevent damage, it is prone to unnecessary operation which can lead to cascading outages. Where a secure scheme will not operate unnecessarily, it is prone to pieces of the system becoming damaged when relays fail to operate properly. With microprocessor based relaying schemes, a hybrid reliability focus is attainable through adaptive relaying. Adaptive relaying describes protection schemes that adjust settings and/or logic of operations based on the prevailing conditions of the system. These adjustments can help to avoid relay miss-operation. Adjustments could include, but are not limited to, the logging of data for post-mortem analysis, communication throughout the system, as well changing relay parameters. Several concepts will be discussed, one of which will be implemented to prove the value of the new tools available.","abstract_html":"The electrical distribution system in the United States is considered one of the most complicated machines in existence. Electrical phenomena in such a complex system can inflict serious self-harm. This requires damage prevention from protection schemes. Until recently, there was a safe gap between capacity to deliver power and the demand. Therefore, these protection schemes focused on dependability allowing the disconnection of lines, transformers, or other devices with the purpose of isolating the faulted element. On some occasions, the disconnections made were not necessary. The other extreme of reliability calls for security. This aspect of reliability calls for the operation of the protective devices only for faults within the intended area of protection. There is a tradeoff here; where a dependable protection scheme will assuredly prevent damage, it is prone to unnecessary operation which can lead to cascading outages. Where a secure scheme will not operate unnecessarily, it is prone to pieces of the system becoming damaged when relays fail to operate properly. With microprocessor based relaying schemes, a hybrid reliability focus is attainable through adaptive relaying. Adaptive relaying describes protection schemes that adjust settings and/or logic of operations based on the prevailing conditions of the system. These adjustments can help to avoid relay miss-operation. Adjustments could include, but are not limited to, the logging of data for post-mortem analysis, communication throughout the system, as well changing relay parameters. Several concepts will be discussed, one of which will be implemented to prove the value of the new tools available.","abstract_has_math":false,"creators":["Zaremski, Brian Zachary"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["De La Ree, Jaime"],"committee_members":["Centeno, Virgilio A.","Conners, Richard W."],"year":2012,"date_issued":"2012-04-27","date_published":"2012-04-27","updated_at":"2026-07-22T22:20:08Z","subjects":["Loadability","Fault","Rate of Change","Impedance","Current","Voltage","Adaptive Protection","Supervisory Zones"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05022012-120008"],"render_values":[{"text":"etd-05022012-120008","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/32121","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["De La Ree, Jaime"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Centeno, Virgilio A.","Conners, Richard W."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Zaremski, Brian Zachary"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:34:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:34:49Z","2012-05-14"]},{"key":"dc:date.issued","label":"Date","values":["2012-04-27"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Loadability","Fault","Rate of Change","Impedance","Current","Voltage","Adaptive Protection","Supervisory Zones"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05022012-120008"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/32121"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The electrical distribution system in the United States is considered one of the most complicated machines in existence. Electrical phenomena in such a complex system can inflict serious self-harm. This requires damage prevention from protection schemes. Until recently, there was a safe gap between capacity to deliver power and the demand. Therefore, these protection schemes focused on dependability allowing the disconnection of lines, transformers, or other devices with the purpose of isolating the faulted element. On some occasions, the disconnections made were not necessary. The other extreme of reliability calls for security. This aspect of reliability calls for the operation of the protective devices only for faults within the intended area of protection. There is a tradeoff here; where a dependable protection scheme will assuredly prevent damage, it is prone to unnecessary operation which can lead to cascading outages. Where a secure scheme will not operate unnecessarily, it is prone to pieces of the system becoming damaged when relays fail to operate properly. With microprocessor based relaying schemes, a hybrid reliability focus is attainable through adaptive relaying. Adaptive relaying describes protection schemes that adjust settings and/or logic of operations based on the prevailing conditions of the system. These adjustments can help to avoid relay miss-operation. Adjustments could include, but are not limited to, the logging of data for post-mortem analysis, communication throughout the system, as well changing relay parameters. Several concepts will be discussed, one of which will be implemented to prove the value of the new tools available."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["The Advancement of Adaptive Relaying in Power Systems Protection"]}]}],"canonical_facts":{"dc:contributor.committeechair":["De La Ree, Jaime"],"dc:contributor.committeemember":["Centeno, Virgilio A.","Conners, Richard W."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Zaremski, Brian Zachary"],"dc:date.accessioned":["2014-03-14T20:34:49Z"],"dc:date.available":["2014-03-14T20:34:49Z","2012-05-14"],"dc:date.issued":["2012-04-27"],"dc:description.abstract":["The electrical distribution system in the United States is considered one of the most complicated machines in existence. Electrical phenomena in such a complex system can inflict serious self-harm. This requires damage prevention from protection schemes. Until recently, there was a safe gap between capacity to deliver power and the demand. Therefore, these protection schemes focused on dependability allowing the disconnection of lines, transformers, or other devices with the purpose of isolating the faulted element. On some occasions, the disconnections made were not necessary. The other extreme of reliability calls for security. This aspect of reliability calls for the operation of the protective devices only for faults within the intended area of protection. There is a tradeoff here; where a dependable protection scheme will assuredly prevent damage, it is prone to unnecessary operation which can lead to cascading outages. Where a secure scheme will not operate unnecessarily, it is prone to pieces of the system becoming damaged when relays fail to operate properly. With microprocessor based relaying schemes, a hybrid reliability focus is attainable through adaptive relaying. Adaptive relaying describes protection schemes that adjust settings and/or logic of operations based on the prevailing conditions of the system. These adjustments can help to avoid relay miss-operation. Adjustments could include, but are not limited to, the logging of data for post-mortem analysis, communication throughout the system, as well changing relay parameters. Several concepts will be discussed, one of which will be implemented to prove the value of the new tools available."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-05022012-120008"],"dc:identifier.uri":["http://hdl.handle.net/10919/32121"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Loadability","Fault","Rate of Change","Impedance","Current","Voltage","Adaptive Protection","Supervisory Zones"],"dc:title":["The Advancement of Adaptive Relaying in Power Systems Protection"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:08Z"}