{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31802"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31802","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A Protocol to Determine the Performance of South Facing Double Glass Façade System-A Preliminary Study of Active/Passive Double Glass Façade Systems","abstract":"This project proposes a protocol for experimentally determining the performance of a double glass envelope system. As a proof of concept, the protocol was applied to an experimental study of a south-facing, single story double glazed ventilated wall system. Two modular full-scale double glazed window models with naturally or mechanically assisted ventilation were constructed and monitored for a range of weather conditions. The goals of this investigation were to develop and apply the test protocol and to monitor and analyze the thermal performance of these two systems and to improve our understanding of the double façade system. Using this test protocol preliminary results show the average cavity heat removal rate is approximately 25% higher for the active system when compared to the naturally ventilated system. Also, the passive system has a higher temperature difference between the indoor glass surface and the indoor air than the active system. This experimental protocol can be further applied to determine other performance issues of the double envelope system.","abstract_html":"This project proposes a protocol for experimentally determining the performance of a double glass envelope system. As a proof of concept, the protocol was applied to an experimental study of a south-facing, single story double glazed ventilated wall system. Two modular full-scale double glazed window models with naturally or mechanically assisted ventilation were constructed and monitored for a range of weather conditions. The goals of this investigation were to develop and apply the test protocol and to monitor and analyze the thermal performance of these two systems and to improve our understanding of the double façade system. Using this test protocol preliminary results show the average cavity heat removal rate is approximately 25% higher for the active system when compared to the naturally ventilated system. Also, the passive system has a higher temperature difference between the indoor glass surface and the indoor air than the active system. This experimental protocol can be further applied to determine other performance issues of the double envelope system.","abstract_has_math":false,"creators":["Li, Shang-Shiou"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Architecture","degree_department":"Architecture","school":null,"contributors":[],"advisors":[],"committee_chairs":["Jones, James R."],"committee_members":[],"year":2000,"date_issued":"2000-12-19","date_published":"2000-12-19","updated_at":"2026-07-22T22:20:00Z","subjects":["double glass faÃ§ade","energy efficiency","double envelope","intelligent faÃ§ade"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04212001-152253"],"render_values":[{"text":"etd-04212001-152253","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/31802","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Jones, James R."]},{"key":"dc:contributor.department","label":"Department","values":["Architecture"]},{"key":"dc:creator","label":"Author","values":["Li, Shang-Shiou"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:33:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:33:58Z","2002-05-31"]},{"key":"dc:date.issued","label":"Date","values":["2000-12-19"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Architecture"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["double glass faÃ§ade","energy efficiency","double envelope","intelligent faÃ§ade"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04212001-152253"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31802"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This project proposes a protocol for experimentally determining the performance of a double glass envelope system. As a proof of concept, the protocol was applied to an experimental study of a south-facing, single story double glazed ventilated wall system. Two modular full-scale double glazed window models with naturally or mechanically assisted ventilation were constructed and monitored for a range of weather conditions. The goals of this investigation were to develop and apply the test protocol and to monitor and analyze the thermal performance of these two systems and to improve our understanding of the double façade system. Using this test protocol preliminary results show the average cavity heat removal rate is approximately 25% higher for the active system when compared to the naturally ventilated system. Also, the passive system has a higher temperature difference between the indoor glass surface and the indoor air than the active system. This experimental protocol can be further applied to determine other performance issues of the double envelope system."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["A Protocol to Determine the Performance of South Facing Double Glass Façade System-A Preliminary Study of Active/Passive Double Glass Façade Systems"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Jones, James R."],"dc:contributor.department":["Architecture"],"dc:creator":["Li, Shang-Shiou"],"dc:date.accessioned":["2014-03-14T20:33:58Z"],"dc:date.available":["2014-03-14T20:33:58Z","2002-05-31"],"dc:date.issued":["2000-12-19"],"dc:description.abstract":["This project proposes a protocol for experimentally determining the performance of a double glass envelope system. As a proof of concept, the protocol was applied to an experimental study of a south-facing, single story double glazed ventilated wall system. Two modular full-scale double glazed window models with naturally or mechanically assisted ventilation were constructed and monitored for a range of weather conditions. The goals of this investigation were to develop and apply the test protocol and to monitor and analyze the thermal performance of these two systems and to improve our understanding of the double façade system. Using this test protocol preliminary results show the average cavity heat removal rate is approximately 25% higher for the active system when compared to the naturally ventilated system. Also, the passive system has a higher temperature difference between the indoor glass surface and the indoor air than the active system. This experimental protocol can be further applied to determine other performance issues of the double envelope system."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-04212001-152253"],"dc:identifier.uri":["http://hdl.handle.net/10919/31802"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["double glass faÃ§ade","energy efficiency","double envelope","intelligent faÃ§ade"],"dc:title":["A Protocol to Determine the Performance of South Facing Double Glass Façade System-A Preliminary Study of Active/Passive Double Glass Façade Systems"],"dc:type":["Thesis"],"thesis:degree_discipline":["Architecture"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:00Z"}