Back to results

Virginia Tech

A Comparative In Vitro Study of the Flow Characteristics Distal to Mechanical and Natural Mitral Valves

Abstract

dc:description.abstract

Mechanical heart valve (MHV) flows are characterized by high shear stress, regions of recirculation, and high levels of turbulent fluctuations. It is well known that these flow conditions are hostile to blood constituents, which could lead to thromboembolism. In the ongoing effort to reduce long-term complications and morbidity, it is imperative that we better understand the flow characteristics of the natural valve as well as that of the mechanical valve. In this study, we overcome many of the limitations imposed by other measurement techniques by employing a powerful, high-speed Time-Resolved Digital Particle Image Velocimetry (TRDPIV) system to map the flow field. We compare the flows downstream from a St. Jude Medical bileaflet MHV, a porcine mitral valve (MV), and a combination of both valves to simulate the technique of chordal preservation. Instantaneous velocity fields and vorticity maps are presented, which provide detailed information about the development of the flow. Time-averaged velocity, vorticity, and turbulent kinetic energy measurements are also discussed. Asynchronous leaflet behavior was observed in all cases involving the mechanical valve. Extensive vortex formation and propagation are present distal to the MHV, which leads to high levels of jet dispersion. The porcine mitral jet exhibits lateral oscillatory behavior, but it does not disperse like the MHV. In the MHV/porcine combination system, the native tissue limits vortex propagation and jet dispersion. The results presented provide insight on the hemodynamic characteristics of natural and MHVs, reveal the detrimental character of asynchronous leaflet opening, document the mechanism of vortex formation and interaction distal to the valve, and illustrate the importance of chordal preservation. These results may improve MHV replacement clinical practice and/or motivate and aid the design of MHVs that better mimic natural mitral flow patterns.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering Science and Mechanics
Department dc:contributor.department
Engineering Science and Mechanics
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mace, Amber
Chair dc:contributor.committeechair
  • Telionis, Demetri P.
Committee members dc:contributor.committeemember
  • Pyle, Robert Lee
  • Vlachos, Pavlos P.
  • Grant, John Wallace

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-03252003-124256
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/31540

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation