{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31465"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31465","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Negative phototaxis of mosquito larvae as a potential tool in the rapid biological monitoring of aquatic wastes (Diptera: Culicidae)","abstract":"A little-known approach to toxicity testing--based on negative phototaxis of larval <u>Aedes aegypti</u>--was investigated as a contribution to the search for rapid methods applicable to the field of water pollution control. Zinc and copper were the toxicants tested. All tests were conducted with a standard \"synthetic\" dilution water. A mosquito colony was established to provide a uniform supply of test larvae. Preliminary tests were performed on the acute toxicity of zinc and copper against <u>A. aegypti</u> larvae, as well as tests on larval growth and development at various concentrations of the metals. For the photomigration toxicity tests, two juxtaposed troughs were used, one containing the test solution, the other a control. Third instar larvae migrated away from a six-watt fluorescent light for two minutes per run. This was repeated at intervals until 50% were unable to migrate 50 cm in 120 sec. Photographs were taken of the larval migrations. From the pictures an empirical criterion was derived (the 40-cm, 60-sec ET₅₀) through a series of graphical interpolations. All inactivation analyses were based on this criterion. From time-inactivation regression lines, exponential toxicity curves were obtained by interpolation. The curves were of an unusual shape, depicting the characteristic nature of the dosage-response. The sensitivity of the inactivation technique was comparable to that of the acute toxicity tests. However, inactivation was far quicker; depending on concentration, it occurred within one to five hours. By all methods used in this study, zinc and copper were judged to be slow-acting and of low overall toxicity. Copper was, however, consistently more toxic than zinc by at least one order of magnitude. The ET₅₀ in 10 ppm Cu⁺⁺ was 147 min.; in 10 ppm Zn⁺⁺, it was 209 min. Some possible improvements in technique were discussed. It was suggested that the photornigration approach to toxicity testing can be of definite practical use to biologists in water pollution control.","abstract_html":"A little-known approach to toxicity testing--based on negative phototaxis of larval &lt;u&gt;Aedes aegypti&lt;/u&gt;--was investigated as a contribution to the search for rapid methods applicable to the field of water pollution control. Zinc and copper were the toxicants tested. All tests were conducted with a standard &quot;synthetic&quot; dilution water. A mosquito colony was established to provide a uniform supply of test larvae. Preliminary tests were performed on the acute toxicity of zinc and copper against &lt;u&gt;A. aegypti&lt;/u&gt; larvae, as well as tests on larval growth and development at various concentrations of the metals. For the photomigration toxicity tests, two juxtaposed troughs were used, one containing the test solution, the other a control. Third instar larvae migrated away from a six-watt fluorescent light for two minutes per run. This was repeated at intervals until 50% were unable to migrate 50 cm in 120 sec. Photographs were taken of the larval migrations. From the pictures an empirical criterion was derived (the 40-cm, 60-sec ET₅₀) through a series of graphical interpolations. All inactivation analyses were based on this criterion. From time-inactivation regression lines, exponential toxicity curves were obtained by interpolation. The curves were of an unusual shape, depicting the characteristic nature of the dosage-response. The sensitivity of the inactivation technique was comparable to that of the acute toxicity tests. However, inactivation was far quicker; depending on concentration, it occurred within one to five hours. By all methods used in this study, zinc and copper were judged to be slow-acting and of low overall toxicity. Copper was, however, consistently more toxic than zinc by at least one order of magnitude. The ET₅₀ in 10 ppm Cu⁺⁺ was 147 min.; in 10 ppm Zn⁺⁺, it was 209 min. Some possible improvements in technique were discussed. It was suggested that the photornigration approach to toxicity testing can be of definite practical use to biologists in water pollution control.","abstract_has_math":false,"creators":["Knausenberger, Walter Ingolf"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Entomology","degree_department":"Entomology","school":null,"contributors":[],"advisors":[],"committee_chairs":["Turner, E. Craig Jr."],"committee_members":["Cochran, Donald G.","Kok, Loke T.","Grayson, James McD.","Simmons, George M. Jr."],"year":1975,"date_issued":"1975-02-05","date_published":"1975-02-05","updated_at":"2026-07-22T22:20:11Z","subjects":[],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03132009-040440"],"render_values":[{"text":"etd-03132009-040440","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/31465","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Turner, E. Craig Jr."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cochran, Donald G.","Kok, Loke T.","Grayson, James McD.","Simmons, George M. Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Entomology"]},{"key":"dc:creator","label":"Author","values":["Knausenberger, Walter Ingolf"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:32:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:32:37Z","2009-03-13"]},{"key":"dc:date.issued","label":"Date","values":["1975-02-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Entomology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03132009-040440"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31465"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A little-known approach to toxicity testing--based on negative phototaxis of larval <u>Aedes aegypti</u>--was investigated as a contribution to the search for rapid methods applicable to the field of water pollution control. Zinc and copper were the toxicants tested. All tests were conducted with a standard \"synthetic\" dilution water. A mosquito colony was established to provide a uniform supply of test larvae. Preliminary tests were performed on the acute toxicity of zinc and copper against <u>A. aegypti</u> larvae, as well as tests on larval growth and development at various concentrations of the metals. For the photomigration toxicity tests, two juxtaposed troughs were used, one containing the test solution, the other a control. Third instar larvae migrated away from a six-watt fluorescent light for two minutes per run. This was repeated at intervals until 50% were unable to migrate 50 cm in 120 sec. Photographs were taken of the larval migrations. From the pictures an empirical criterion was derived (the 40-cm, 60-sec ET₅₀) through a series of graphical interpolations. All inactivation analyses were based on this criterion. From time-inactivation regression lines, exponential toxicity curves were obtained by interpolation. The curves were of an unusual shape, depicting the characteristic nature of the dosage-response. The sensitivity of the inactivation technique was comparable to that of the acute toxicity tests. However, inactivation was far quicker; depending on concentration, it occurred within one to five hours. By all methods used in this study, zinc and copper were judged to be slow-acting and of low overall toxicity. Copper was, however, consistently more toxic than zinc by at least one order of magnitude. The ET₅₀ in 10 ppm Cu⁺⁺ was 147 min.; in 10 ppm Zn⁺⁺, it was 209 min. Some possible improvements in technique were discussed. It was suggested that the photornigration approach to toxicity testing can be of definite practical use to biologists in water pollution control."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Negative phototaxis of mosquito larvae as a potential tool in the rapid biological monitoring of aquatic wastes (Diptera: Culicidae)"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Turner, E. Craig Jr."],"dc:contributor.committeemember":["Cochran, Donald G.","Kok, Loke T.","Grayson, James McD.","Simmons, George M. Jr."],"dc:contributor.department":["Entomology"],"dc:creator":["Knausenberger, Walter Ingolf"],"dc:date.accessioned":["2014-03-14T20:32:37Z"],"dc:date.available":["2014-03-14T20:32:37Z","2009-03-13"],"dc:date.issued":["1975-02-05"],"dc:description.abstract":["A little-known approach to toxicity testing--based on negative phototaxis of larval <u>Aedes aegypti</u>--was investigated as a contribution to the search for rapid methods applicable to the field of water pollution control. Zinc and copper were the toxicants tested. All tests were conducted with a standard \"synthetic\" dilution water. A mosquito colony was established to provide a uniform supply of test larvae. Preliminary tests were performed on the acute toxicity of zinc and copper against <u>A. aegypti</u> larvae, as well as tests on larval growth and development at various concentrations of the metals. For the photomigration toxicity tests, two juxtaposed troughs were used, one containing the test solution, the other a control. Third instar larvae migrated away from a six-watt fluorescent light for two minutes per run. This was repeated at intervals until 50% were unable to migrate 50 cm in 120 sec. Photographs were taken of the larval migrations. From the pictures an empirical criterion was derived (the 40-cm, 60-sec ET₅₀) through a series of graphical interpolations. All inactivation analyses were based on this criterion. From time-inactivation regression lines, exponential toxicity curves were obtained by interpolation. The curves were of an unusual shape, depicting the characteristic nature of the dosage-response. The sensitivity of the inactivation technique was comparable to that of the acute toxicity tests. However, inactivation was far quicker; depending on concentration, it occurred within one to five hours. By all methods used in this study, zinc and copper were judged to be slow-acting and of low overall toxicity. Copper was, however, consistently more toxic than zinc by at least one order of magnitude. The ET₅₀ in 10 ppm Cu⁺⁺ was 147 min.; in 10 ppm Zn⁺⁺, it was 209 min. Some possible improvements in technique were discussed. It was suggested that the photornigration approach to toxicity testing can be of definite practical use to biologists in water pollution control."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03132009-040440"],"dc:identifier.uri":["http://hdl.handle.net/10919/31465"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Negative phototaxis of mosquito larvae as a potential tool in the rapid biological monitoring of aquatic wastes (Diptera: Culicidae)"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Entomology"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:11Z"}