{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31446"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31446","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Horizontal Shear Transfer Between Ultra High Performance Concrete And Lightweight Concrete","abstract":"Ultra high performance concrete, specifically DuctalÂ® concrete, has begun to revolutionize the bridge design industry. This extremely high strength material has given smaller composite sections the ability to carry larger loads. As the forces being transferred through composite members are increasing in magnitude, it is vital that the equations being used for design are applicable for use with the new materials. Of particular importance is the design of the horizontal shear reinforcement connecting the bridge deck to the top flange of the beams. Without adequate shear transfer, the flexural and shearing capacities will be greatly diminished. The current design equations from ACI and AASHTO were not developed for use in designing sections composed of DuctalÂ® and Lightweight concrete. Twenty-four push-off tests were performed to determine if the current horizontal shear design equations could accurately predict the horizontal shear strength of composite DuctalÂ® and Lightweight concrete sections. Effects from various surface treatments, reinforcement ratios, and aspect ratios, were determined. The results predicted by the current design equations were compared to the actual results found during testing. The current design equations were all found to be conservative. For its ability to incorporate various cohesion and friction factors, it is recommended that the equation from AASHTO LRFD Specification (2004) be used for design.","abstract_html":"Ultra high performance concrete, specifically DuctalÂ® concrete, has begun to revolutionize the bridge design industry. This extremely high strength material has given smaller composite sections the ability to carry larger loads. As the forces being transferred through composite members are increasing in magnitude, it is vital that the equations being used for design are applicable for use with the new materials. Of particular importance is the design of the horizontal shear reinforcement connecting the bridge deck to the top flange of the beams. Without adequate shear transfer, the flexural and shearing capacities will be greatly diminished. The current design equations from ACI and AASHTO were not developed for use in designing sections composed of DuctalÂ® and Lightweight concrete. Twenty-four push-off tests were performed to determine if the current horizontal shear design equations could accurately predict the horizontal shear strength of composite DuctalÂ® and Lightweight concrete sections. Effects from various surface treatments, reinforcement ratios, and aspect ratios, were determined. The results predicted by the current design equations were compared to the actual results found during testing. The current design equations were all found to be conservative. For its ability to incorporate various cohesion and friction factors, it is recommended that the equation from AASHTO LRFD Specification (2004) be used for design.","abstract_has_math":false,"creators":["Banta, Timothy E."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Roberts-Wollmann, Carin L."],"committee_members":["Cousins, Thomas E.","Easterling, William Samuel"],"year":2005,"date_issued":"2005-02-11","date_published":"2005-02-11","updated_at":"2026-07-22T22:20:03Z","subjects":["Horizontal Shear Transfer","Lightweight","Ductal"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03112005-113817"],"render_values":[{"text":"etd-03112005-113817","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/31446","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Roberts-Wollmann, Carin L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cousins, Thomas E.","Easterling, William Samuel"]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Banta, Timothy E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:32:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:32:30Z","2006-03-28"]},{"key":"dc:date.issued","label":"Date","values":["2005-02-11"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Horizontal Shear Transfer","Lightweight","Ductal"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03112005-113817"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31446"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ultra high performance concrete, specifically DuctalÂ® concrete, has begun to revolutionize the bridge design industry. This extremely high strength material has given smaller composite sections the ability to carry larger loads. As the forces being transferred through composite members are increasing in magnitude, it is vital that the equations being used for design are applicable for use with the new materials. Of particular importance is the design of the horizontal shear reinforcement connecting the bridge deck to the top flange of the beams. Without adequate shear transfer, the flexural and shearing capacities will be greatly diminished. The current design equations from ACI and AASHTO were not developed for use in designing sections composed of DuctalÂ® and Lightweight concrete. Twenty-four push-off tests were performed to determine if the current horizontal shear design equations could accurately predict the horizontal shear strength of composite DuctalÂ® and Lightweight concrete sections. Effects from various surface treatments, reinforcement ratios, and aspect ratios, were determined. The results predicted by the current design equations were compared to the actual results found during testing. The current design equations were all found to be conservative. For its ability to incorporate various cohesion and friction factors, it is recommended that the equation from AASHTO LRFD Specification (2004) be used for design."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Horizontal Shear Transfer Between Ultra High Performance Concrete And Lightweight Concrete"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Roberts-Wollmann, Carin L."],"dc:contributor.committeemember":["Cousins, Thomas E.","Easterling, William Samuel"],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Banta, Timothy E."],"dc:date.accessioned":["2014-03-14T20:32:30Z"],"dc:date.available":["2014-03-14T20:32:30Z","2006-03-28"],"dc:date.issued":["2005-02-11"],"dc:description.abstract":["Ultra high performance concrete, specifically DuctalÂ® concrete, has begun to revolutionize the bridge design industry. This extremely high strength material has given smaller composite sections the ability to carry larger loads. As the forces being transferred through composite members are increasing in magnitude, it is vital that the equations being used for design are applicable for use with the new materials. Of particular importance is the design of the horizontal shear reinforcement connecting the bridge deck to the top flange of the beams. Without adequate shear transfer, the flexural and shearing capacities will be greatly diminished. The current design equations from ACI and AASHTO were not developed for use in designing sections composed of DuctalÂ® and Lightweight concrete. Twenty-four push-off tests were performed to determine if the current horizontal shear design equations could accurately predict the horizontal shear strength of composite DuctalÂ® and Lightweight concrete sections. Effects from various surface treatments, reinforcement ratios, and aspect ratios, were determined. The results predicted by the current design equations were compared to the actual results found during testing. The current design equations were all found to be conservative. For its ability to incorporate various cohesion and friction factors, it is recommended that the equation from AASHTO LRFD Specification (2004) be used for design."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-03112005-113817"],"dc:identifier.uri":["http://hdl.handle.net/10919/31446"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Horizontal Shear Transfer","Lightweight","Ductal"],"dc:title":["Horizontal Shear Transfer Between Ultra High Performance Concrete And Lightweight Concrete"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:03Z"}