{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31357"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31357","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Hemocompatible polymer thin films fabricated by Electrostatic Self-Assembly (ESA)","abstract":"Stent is one of the coronary angioplasty techniques that expands the narrowed coronary arteries due to the accumulation of fat, cholesterol and other substances in the lumen of the arteries. The major complication of stent is restenosis. Current development of drug-eluting stents shows successfully reduce the occurrence of restenosis. Other than using drugs, electrostatic self assembled (ESAd) thin films may be the potential candidates to prevent restenosis. ESA is a process to fabricate thin films bases on the electrostatic attraction between two oppositely charges. We used this technique to fabricate four PVP films and four PEI films. All films were examined by XPS and AFM. XPS data showed our coatings were successfully fabricated on substrates. AFM images revealed PVP coating was uniform, but PEI coatings had different morphologies due to diffusion and pH during the process. Three preliminary hemocompatibility testes were performed to evaluate the hemocompatibility of the coatings. Platelet adhesion study showed the thin films inhibited platelet adhesion. All thin films were able to inhibit coagulation and were less cytotoxic. The studies suggested the ESA films were potentially hemocompatible.","abstract_html":"Stent is one of the coronary angioplasty techniques that expands the narrowed coronary arteries due to the accumulation of fat, cholesterol and other substances in the lumen of the arteries. The major complication of stent is restenosis. Current development of drug-eluting stents shows successfully reduce the occurrence of restenosis. Other than using drugs, electrostatic self assembled (ESAd) thin films may be the potential candidates to prevent restenosis. ESA is a process to fabricate thin films bases on the electrostatic attraction between two oppositely charges. We used this technique to fabricate four PVP films and four PEI films. All films were examined by XPS and AFM. XPS data showed our coatings were successfully fabricated on substrates. AFM images revealed PVP coating was uniform, but PEI coatings had different morphologies due to diffusion and pH during the process. Three preliminary hemocompatibility testes were performed to evaluate the hemocompatibility of the coatings. Platelet adhesion study showed the thin films inhibited platelet adhesion. All thin films were able to inhibit coagulation and were less cytotoxic. The studies suggested the ESA films were potentially hemocompatible.","abstract_has_math":false,"creators":["Cheung, Yeuk Kit"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Materials Science and Engineering","degree_department":"Materials Science and Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Claus, Richard O."],"committee_members":["Corcoran, Sean G.","Robertson, John L."],"year":2004,"date_issued":"2004-12-14","date_published":"2004-12-14","updated_at":"2026-07-22T22:20:29Z","subjects":["cytotoxicity","platelet adhesion","coagulation","hemocompatible","stent","electrostatic self-assembly (ESA)"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02262005-143358"],"render_values":[{"text":"etd-02262005-143358","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/31357","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Claus, Richard O."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Corcoran, Sean G.","Robertson, John L."]},{"key":"dc:contributor.department","label":"Department","values":["Materials Science and Engineering"]},{"key":"dc:creator","label":"Author","values":["Cheung, Yeuk Kit"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:32:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:32:12Z","2012-06-22"]},{"key":"dc:date.issued","label":"Date","values":["2004-12-14"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cytotoxicity","platelet adhesion","coagulation","hemocompatible","stent","electrostatic self-assembly (ESA)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02262005-143358"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31357"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Stent is one of the coronary angioplasty techniques that expands the narrowed coronary arteries due to the accumulation of fat, cholesterol and other substances in the lumen of the arteries. The major complication of stent is restenosis. Current development of drug-eluting stents shows successfully reduce the occurrence of restenosis. Other than using drugs, electrostatic self assembled (ESAd) thin films may be the potential candidates to prevent restenosis. ESA is a process to fabricate thin films bases on the electrostatic attraction between two oppositely charges. We used this technique to fabricate four PVP films and four PEI films. All films were examined by XPS and AFM. XPS data showed our coatings were successfully fabricated on substrates. AFM images revealed PVP coating was uniform, but PEI coatings had different morphologies due to diffusion and pH during the process. Three preliminary hemocompatibility testes were performed to evaluate the hemocompatibility of the coatings. Platelet adhesion study showed the thin films inhibited platelet adhesion. All thin films were able to inhibit coagulation and were less cytotoxic. The studies suggested the ESA films were potentially hemocompatible."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Hemocompatible polymer thin films fabricated by Electrostatic Self-Assembly (ESA)"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Claus, Richard O."],"dc:contributor.committeemember":["Corcoran, Sean G.","Robertson, John L."],"dc:contributor.department":["Materials Science and Engineering"],"dc:creator":["Cheung, Yeuk Kit"],"dc:date.accessioned":["2014-03-14T20:32:12Z"],"dc:date.available":["2014-03-14T20:32:12Z","2012-06-22"],"dc:date.issued":["2004-12-14"],"dc:description.abstract":["Stent is one of the coronary angioplasty techniques that expands the narrowed coronary arteries due to the accumulation of fat, cholesterol and other substances in the lumen of the arteries. The major complication of stent is restenosis. Current development of drug-eluting stents shows successfully reduce the occurrence of restenosis. Other than using drugs, electrostatic self assembled (ESAd) thin films may be the potential candidates to prevent restenosis. ESA is a process to fabricate thin films bases on the electrostatic attraction between two oppositely charges. We used this technique to fabricate four PVP films and four PEI films. All films were examined by XPS and AFM. XPS data showed our coatings were successfully fabricated on substrates. AFM images revealed PVP coating was uniform, but PEI coatings had different morphologies due to diffusion and pH during the process. Three preliminary hemocompatibility testes were performed to evaluate the hemocompatibility of the coatings. Platelet adhesion study showed the thin films inhibited platelet adhesion. All thin films were able to inhibit coagulation and were less cytotoxic. The studies suggested the ESA films were potentially hemocompatible."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-02262005-143358"],"dc:identifier.uri":["http://hdl.handle.net/10919/31357"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["cytotoxicity","platelet adhesion","coagulation","hemocompatible","stent","electrostatic self-assembly (ESA)"],"dc:title":["Hemocompatible polymer thin films fabricated by Electrostatic Self-Assembly (ESA)"],"dc:type":["Thesis"],"thesis:degree_discipline":["Materials Science and Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:29Z"}