{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31260"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31260","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Carbon Monoxide Generation in a Compartment With a Doorway During a Fire","abstract":"The study of the products of combustion continues to have real-world relevance since the primary cause of death in building fires is smoke inhalation, with the majority of deaths from carbon monoxide, CO, poisoning. An experimental study was conducted to examine upper-layer structure plus provide an initial characterization of a new compartment with a doorway. An additional study of the relationship between heat flux from external burning in a hallway and levels of carbon monoxide is also reported. Tests were conducted in a new Â½ scale ISO compartment with a fully scaled doorway, using n-hexane pool fires within the center of the compartment. Upper-layer sampling at eight locations in the compartment has shown that the compartment upper-layer is relatively uniform in species mole fractions, yields, and temperature. Sampling in the front upper-layer of the compartment was performed for a series of experiments where the equivalence ratio was varied. Temperatures, species mole fractions, species yields, and doorway flows were found to have definite trends, which agreed with previous studies. The heat flux study utilized a reduced scale compartment with a separate inlet and an exit vent, which connected into the side of an attached hallway, forming an L-shape. For two cases of a deep and shallow hallway upper-layer a direct relationship between flames in the upper-layer and total heat flux was measured. High heat flux was found to only denote those areas were flames are present and is not related to the levels of CO present or oxidized in the hallway.","abstract_html":"The study of the products of combustion continues to have real-world relevance since the primary cause of death in building fires is smoke inhalation, with the majority of deaths from carbon monoxide, CO, poisoning. An experimental study was conducted to examine upper-layer structure plus provide an initial characterization of a new compartment with a doorway. An additional study of the relationship between heat flux from external burning in a hallway and levels of carbon monoxide is also reported. Tests were conducted in a new Â½ scale ISO compartment with a fully scaled doorway, using n-hexane pool fires within the center of the compartment. Upper-layer sampling at eight locations in the compartment has shown that the compartment upper-layer is relatively uniform in species mole fractions, yields, and temperature. Sampling in the front upper-layer of the compartment was performed for a series of experiments where the equivalence ratio was varied. Temperatures, species mole fractions, species yields, and doorway flows were found to have definite trends, which agreed with previous studies. The heat flux study utilized a reduced scale compartment with a separate inlet and an exit vent, which connected into the side of an attached hallway, forming an L-shape. For two cases of a deep and shallow hallway upper-layer a direct relationship between flames in the upper-layer and total heat flux was measured. High heat flux was found to only denote those areas were flames are present and is not related to the levels of CO present or oxidized in the hallway.","abstract_has_math":false,"creators":["McKay, Christopher A."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Vandsburger, Uri"],"committee_members":["Lattimer, Brian Y.","Saito, Kozo"],"year":2002,"date_issued":"2002-02-04","date_published":"2002-02-04","updated_at":"2026-07-22T22:19:47Z","subjects":["carbon monoxide","doorway flow","heat flux","building fire"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02182002-110939"],"render_values":[{"text":"etd-02182002-110939","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/31260","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Vandsburger, Uri"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lattimer, Brian Y.","Saito, Kozo"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["McKay, Christopher A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:31:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:31:51Z","2003-02-18"]},{"key":"dc:date.issued","label":"Date","values":["2002-02-04"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["carbon monoxide","doorway flow","heat flux","building fire"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02182002-110939"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31260"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The study of the products of combustion continues to have real-world relevance since the primary cause of death in building fires is smoke inhalation, with the majority of deaths from carbon monoxide, CO, poisoning. An experimental study was conducted to examine upper-layer structure plus provide an initial characterization of a new compartment with a doorway. An additional study of the relationship between heat flux from external burning in a hallway and levels of carbon monoxide is also reported. Tests were conducted in a new Â½ scale ISO compartment with a fully scaled doorway, using n-hexane pool fires within the center of the compartment. Upper-layer sampling at eight locations in the compartment has shown that the compartment upper-layer is relatively uniform in species mole fractions, yields, and temperature. Sampling in the front upper-layer of the compartment was performed for a series of experiments where the equivalence ratio was varied. Temperatures, species mole fractions, species yields, and doorway flows were found to have definite trends, which agreed with previous studies. The heat flux study utilized a reduced scale compartment with a separate inlet and an exit vent, which connected into the side of an attached hallway, forming an L-shape. For two cases of a deep and shallow hallway upper-layer a direct relationship between flames in the upper-layer and total heat flux was measured. High heat flux was found to only denote those areas were flames are present and is not related to the levels of CO present or oxidized in the hallway."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Carbon Monoxide Generation in a Compartment With a Doorway During a Fire"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Vandsburger, Uri"],"dc:contributor.committeemember":["Lattimer, Brian Y.","Saito, Kozo"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["McKay, Christopher A."],"dc:date.accessioned":["2014-03-14T20:31:51Z"],"dc:date.available":["2014-03-14T20:31:51Z","2003-02-18"],"dc:date.issued":["2002-02-04"],"dc:description.abstract":["The study of the products of combustion continues to have real-world relevance since the primary cause of death in building fires is smoke inhalation, with the majority of deaths from carbon monoxide, CO, poisoning. An experimental study was conducted to examine upper-layer structure plus provide an initial characterization of a new compartment with a doorway. An additional study of the relationship between heat flux from external burning in a hallway and levels of carbon monoxide is also reported. Tests were conducted in a new Â½ scale ISO compartment with a fully scaled doorway, using n-hexane pool fires within the center of the compartment. Upper-layer sampling at eight locations in the compartment has shown that the compartment upper-layer is relatively uniform in species mole fractions, yields, and temperature. Sampling in the front upper-layer of the compartment was performed for a series of experiments where the equivalence ratio was varied. Temperatures, species mole fractions, species yields, and doorway flows were found to have definite trends, which agreed with previous studies. The heat flux study utilized a reduced scale compartment with a separate inlet and an exit vent, which connected into the side of an attached hallway, forming an L-shape. For two cases of a deep and shallow hallway upper-layer a direct relationship between flames in the upper-layer and total heat flux was measured. High heat flux was found to only denote those areas were flames are present and is not related to the levels of CO present or oxidized in the hallway."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-02182002-110939"],"dc:identifier.uri":["http://hdl.handle.net/10919/31260"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["carbon monoxide","doorway flow","heat flux","building fire"],"dc:title":["Carbon Monoxide Generation in a Compartment With a Doorway During a Fire"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:47Z"}