{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31190"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31190","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Heat Transfer from Multiple Row Arrays of Low Aspect Ratio Pin Fins","abstract":"The heat transfer characteristics through arrays of pin fins were studied for the further development of internal cooling methods for turbine airfoils. Low aspect ratio pin fin arrays were tested through a range of Reynolds numbers between 5000 and 30,000 to determine the effects of pin spacing as well as aspect ratio on pin and endwall heat transfer. Experiments were also conducted to determine the independent effects of pin spacing and aspect ratio on arrays with different flow incidence angles. The pin Nusselt numbers showed almost no dependence on pin spacing or flow incidence angle. Using an infrared thermogaphy technique, spatially-resolved Nusselt numbers were measured along the endwalls of each array. The endwall results showed that streamwise spacing had a larger effect than spanwise spacing on array-averaged Nusselt numbers. Endwall heat transfer patterns showed that arrays with flow incidence angles experienced less wake interaction between pins than arrays with perpendicular flow, which caused a slight decrease in heat transfer in arrays with flow incidence angles. The effect of flow incidence angle on array-average Nusselt number was greater at tighter pin spacings. Even though the pin Nusselt number was independent of pin spacing, the ratio of pin-to-endwall Nusselt number was dependent on flow conditions as well as pin spacing. The pin aspect ratio had little effect on the array-average Nusselt number for arrays with perpendicular flow; however, the effect of flow incidence angle on array-average Nusselt number increased as aspect ratio decreased.","abstract_html":"The heat transfer characteristics through arrays of pin fins were studied for the further development of internal cooling methods for turbine airfoils. Low aspect ratio pin fin arrays were tested through a range of Reynolds numbers between 5000 and 30,000 to determine the effects of pin spacing as well as aspect ratio on pin and endwall heat transfer. Experiments were also conducted to determine the independent effects of pin spacing and aspect ratio on arrays with different flow incidence angles. The pin Nusselt numbers showed almost no dependence on pin spacing or flow incidence angle. Using an infrared thermogaphy technique, spatially-resolved Nusselt numbers were measured along the endwalls of each array. The endwall results showed that streamwise spacing had a larger effect than spanwise spacing on array-averaged Nusselt numbers. Endwall heat transfer patterns showed that arrays with flow incidence angles experienced less wake interaction between pins than arrays with perpendicular flow, which caused a slight decrease in heat transfer in arrays with flow incidence angles. The effect of flow incidence angle on array-average Nusselt number was greater at tighter pin spacings. Even though the pin Nusselt number was independent of pin spacing, the ratio of pin-to-endwall Nusselt number was dependent on flow conditions as well as pin spacing. The pin aspect ratio had little effect on the array-average Nusselt number for arrays with perpendicular flow; however, the effect of flow incidence angle on array-average Nusselt number increased as aspect ratio decreased.","abstract_has_math":false,"creators":["Lawson, Seth Augustus"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Thole, Karen A."],"committee_members":["O'Brien, Walter F. Jr.","Vick, Brian L."],"year":2007,"date_issued":"2007-02-08","date_published":"2007-02-08","updated_at":"2026-07-22T22:19:35Z","subjects":["pin fins","internal cooling","Heat--Transmission augmentation","gas turbines","Heat--Transmission"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02092007-155521"],"render_values":[{"text":"etd-02092007-155521","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/31190","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Thole, Karen A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["O'Brien, Walter F. Jr.","Vick, Brian L."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Lawson, Seth Augustus"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:31:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:31:39Z","2010-10-27"]},{"key":"dc:date.issued","label":"Date","values":["2007-02-08"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["pin fins","internal cooling","Heat--Transmission augmentation","gas turbines","Heat--Transmission"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02092007-155521"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31190"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The heat transfer characteristics through arrays of pin fins were studied for the further development of internal cooling methods for turbine airfoils. Low aspect ratio pin fin arrays were tested through a range of Reynolds numbers between 5000 and 30,000 to determine the effects of pin spacing as well as aspect ratio on pin and endwall heat transfer. Experiments were also conducted to determine the independent effects of pin spacing and aspect ratio on arrays with different flow incidence angles. The pin Nusselt numbers showed almost no dependence on pin spacing or flow incidence angle. Using an infrared thermogaphy technique, spatially-resolved Nusselt numbers were measured along the endwalls of each array. The endwall results showed that streamwise spacing had a larger effect than spanwise spacing on array-averaged Nusselt numbers. Endwall heat transfer patterns showed that arrays with flow incidence angles experienced less wake interaction between pins than arrays with perpendicular flow, which caused a slight decrease in heat transfer in arrays with flow incidence angles. The effect of flow incidence angle on array-average Nusselt number was greater at tighter pin spacings. Even though the pin Nusselt number was independent of pin spacing, the ratio of pin-to-endwall Nusselt number was dependent on flow conditions as well as pin spacing. The pin aspect ratio had little effect on the array-average Nusselt number for arrays with perpendicular flow; however, the effect of flow incidence angle on array-average Nusselt number increased as aspect ratio decreased."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Heat Transfer from Multiple Row Arrays of Low Aspect Ratio Pin Fins"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Thole, Karen A."],"dc:contributor.committeemember":["O'Brien, Walter F. Jr.","Vick, Brian L."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Lawson, Seth Augustus"],"dc:date.accessioned":["2014-03-14T20:31:39Z"],"dc:date.available":["2014-03-14T20:31:39Z","2010-10-27"],"dc:date.issued":["2007-02-08"],"dc:description.abstract":["The heat transfer characteristics through arrays of pin fins were studied for the further development of internal cooling methods for turbine airfoils. Low aspect ratio pin fin arrays were tested through a range of Reynolds numbers between 5000 and 30,000 to determine the effects of pin spacing as well as aspect ratio on pin and endwall heat transfer. Experiments were also conducted to determine the independent effects of pin spacing and aspect ratio on arrays with different flow incidence angles. The pin Nusselt numbers showed almost no dependence on pin spacing or flow incidence angle. Using an infrared thermogaphy technique, spatially-resolved Nusselt numbers were measured along the endwalls of each array. The endwall results showed that streamwise spacing had a larger effect than spanwise spacing on array-averaged Nusselt numbers. Endwall heat transfer patterns showed that arrays with flow incidence angles experienced less wake interaction between pins than arrays with perpendicular flow, which caused a slight decrease in heat transfer in arrays with flow incidence angles. The effect of flow incidence angle on array-average Nusselt number was greater at tighter pin spacings. Even though the pin Nusselt number was independent of pin spacing, the ratio of pin-to-endwall Nusselt number was dependent on flow conditions as well as pin spacing. The pin aspect ratio had little effect on the array-average Nusselt number for arrays with perpendicular flow; however, the effect of flow incidence angle on array-average Nusselt number increased as aspect ratio decreased."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-02092007-155521"],"dc:identifier.uri":["http://hdl.handle.net/10919/31190"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["pin fins","internal cooling","Heat--Transmission augmentation","gas turbines","Heat--Transmission"],"dc:title":["Heat Transfer from Multiple Row Arrays of Low Aspect Ratio Pin Fins"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:35Z"}