{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31026"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31026","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Computer Modeling and Simulation of Power Electronics Systems for Stability Analysis","abstract":"This works focuses on analyzing ac/dc hybrid power systems with large number of power converters that can be used for a variety of applications. A computer model of a sample power system is developed. The system consists of various detailed/switching models that are connected together to study the sample system dynamic behavior and to set conditions for safe operation. The stability analysis of this type of power systems has been approached using time domain simulations. There are three types of stability analysis that are studied: steady-state, small-signal analysis and large signal analysis. The steady-state stability analysis is done by investigating the nominal operation of the power electronics system proposed. The small-signal stability of this system is studied by running different parametric case studies. First, the safe values of the main system parameters are defined from the view of the stability of the complete system. Then, these different critical parameters of the system are mapped together to predict their influence on the system. The large signal stability is examined through the response of the power system to different types of transient changes. There are different load steps applied to the critical parameters of the system at the maximum or minimum stability boundary limit found by the mapping section. The maximum load step after which the system can recover and remain stable is defined. The other type of large signal stability analysis done is the study of faults. There are different faults to be studied; for example, over voltage, under voltage and over current.","abstract_html":"This works focuses on analyzing ac/dc hybrid power systems with large number of power converters that can be used for a variety of applications. A computer model of a sample power system is developed. The system consists of various detailed/switching models that are connected together to study the sample system dynamic behavior and to set conditions for safe operation. The stability analysis of this type of power systems has been approached using time domain simulations. There are three types of stability analysis that are studied: steady-state, small-signal analysis and large signal analysis. The steady-state stability analysis is done by investigating the nominal operation of the power electronics system proposed. The small-signal stability of this system is studied by running different parametric case studies. First, the safe values of the main system parameters are defined from the view of the stability of the complete system. Then, these different critical parameters of the system are mapped together to predict their influence on the system. The large signal stability is examined through the response of the power system to different types of transient changes. There are different load steps applied to the critical parameters of the system at the maximum or minimum stability boundary limit found by the mapping section. The maximum load step after which the system can recover and remain stable is defined. The other type of large signal stability analysis done is the study of faults. There are different faults to be studied; for example, over voltage, under voltage and over current.","abstract_has_math":false,"creators":["Ahmed, Sara Mohamed"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Boroyevich, Dushan"],"committee_members":["Wang, Fei Fred","Burgos, Rolando"],"year":2007,"date_issued":"2007-12-05","date_published":"2007-12-05","updated_at":"2026-07-22T22:20:12Z","subjects":["Simulation","fault analysis","stability analysis","Modeling"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01232008-230048"],"render_values":[{"text":"etd-01232008-230048","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/31026","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Boroyevich, Dushan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, Fei Fred","Burgos, Rolando"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Ahmed, Sara Mohamed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:31:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:31:01Z","2009-02-19"]},{"key":"dc:date.issued","label":"Date","values":["2007-12-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Simulation","fault analysis","stability analysis","Modeling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01232008-230048"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31026"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This works focuses on analyzing ac/dc hybrid power systems with large number of power converters that can be used for a variety of applications. A computer model of a sample power system is developed. The system consists of various detailed/switching models that are connected together to study the sample system dynamic behavior and to set conditions for safe operation. The stability analysis of this type of power systems has been approached using time domain simulations. There are three types of stability analysis that are studied: steady-state, small-signal analysis and large signal analysis. The steady-state stability analysis is done by investigating the nominal operation of the power electronics system proposed. The small-signal stability of this system is studied by running different parametric case studies. First, the safe values of the main system parameters are defined from the view of the stability of the complete system. Then, these different critical parameters of the system are mapped together to predict their influence on the system. The large signal stability is examined through the response of the power system to different types of transient changes. There are different load steps applied to the critical parameters of the system at the maximum or minimum stability boundary limit found by the mapping section. The maximum load step after which the system can recover and remain stable is defined. The other type of large signal stability analysis done is the study of faults. There are different faults to be studied; for example, over voltage, under voltage and over current."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Computer Modeling and Simulation of Power Electronics Systems for Stability Analysis"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Boroyevich, Dushan"],"dc:contributor.committeemember":["Wang, Fei Fred","Burgos, Rolando"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Ahmed, Sara Mohamed"],"dc:date.accessioned":["2014-03-14T20:31:01Z"],"dc:date.available":["2014-03-14T20:31:01Z","2009-02-19"],"dc:date.issued":["2007-12-05"],"dc:description.abstract":["This works focuses on analyzing ac/dc hybrid power systems with large number of power converters that can be used for a variety of applications. A computer model of a sample power system is developed. The system consists of various detailed/switching models that are connected together to study the sample system dynamic behavior and to set conditions for safe operation. The stability analysis of this type of power systems has been approached using time domain simulations. There are three types of stability analysis that are studied: steady-state, small-signal analysis and large signal analysis. The steady-state stability analysis is done by investigating the nominal operation of the power electronics system proposed. The small-signal stability of this system is studied by running different parametric case studies. First, the safe values of the main system parameters are defined from the view of the stability of the complete system. Then, these different critical parameters of the system are mapped together to predict their influence on the system. The large signal stability is examined through the response of the power system to different types of transient changes. There are different load steps applied to the critical parameters of the system at the maximum or minimum stability boundary limit found by the mapping section. The maximum load step after which the system can recover and remain stable is defined. The other type of large signal stability analysis done is the study of faults. There are different faults to be studied; for example, over voltage, under voltage and over current."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-01232008-230048"],"dc:identifier.uri":["http://hdl.handle.net/10919/31026"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Simulation","fault analysis","stability analysis","Modeling"],"dc:title":["Computer Modeling and Simulation of Power Electronics Systems for Stability Analysis"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:12Z"}