Back to results

Virginia Tech

Analysis of a dynamic pressure measuring system

Abstract

dc:description.abstract

A dynamic pressure measuring system composed of long connecting tube, transducer, D-C amplifier and galvanometer oscillograph were used in a wind study conducted by the Department of Agricultural Engineering, Virginia Polytechnic Institute. The instrumentation was used to measure and record dynamic pressures due to wind velocity. Data recorded in that study indicated velocity head pressure oscillations on some surfaces of the test structure in excess of 100 Hz. This investigation was undertaken to see if the recorded oscillations could have been generated in the measuring system or if they were truly windpressure variations. Components of the pressure measuring system were modeled by transfer functions. From these transfer functions, a system operational transfer function was determined and used to define system frequency response. The frequency analysis indicated the system was severely limited in response by the oscillating air column constrained within the interconnecting tube. The usable frequency range of the system (+ 10% tolerable amplitude error allowable) was found to go from zero to 34.2 Hz. By eliminating the air column this frequency range could have been extended to 99.4 Hz. Phase shifts in these frequency ranges were found to be negligible. Transducers were mounted rigidly to exterior walls of the test structure. The measured fundamental natural frequencies of these walls (transducer mountings) were found to be well within the usable frequency range of the instrumentation; and, therefore, a source of vibration pickup. To improve the measuring system reliability, recommendations were made to eliminate the air column and stiffen the transducer mountings.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Agricultural Engineering
Department dc:contributor.department
Agricultural Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1970

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Blevins, Roger Allen
Chair dc:contributor.committeechair
  • Mason, J. P. Jr.
Committee members dc:contributor.committeemember
  • Hurst, Charles J.
  • Earp, Unis F.
  • Perumpral, John V.

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-01132010-020009
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/30932

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Blevins, Roger Allen. Analysis of a dynamic pressure measuring system. masters thesis, Virginia Tech, 1970. http://hdl.handle.net/10919/30932