{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/30863"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/30863","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Capacity Resistance and Performance of Single-Shear Bolted and Nailed Connections: An Experimental Investigation","abstract":"The experimental study reported upon in this thesis focused on the development of physical data characterizing the behavior of single-shear, laterally-loaded connections when loaded up to and beyond capacity (i.e., maximum resistance). Specimens included a wide array of connection configurations common in wood construction. All connections were tested monotonically in tension under displacement-controlled loading, parallel to the grain. Results of these tests are presented and discussed. Test variables of nailed connections included nail diameter, side member material type, and side member thickness. Test variables of bolted connections included bolt diameter, commercial species grouping of the main and side members, and main member thickness. Conclusions drawn from this research include mechanics-based explanations of numerous connection response trends observed with respect to test variables. Additionally, observed factors of safety and over-strengths of current design values are quantified on a capacity-basis.","abstract_html":"The experimental study reported upon in this thesis focused on the development of physical data characterizing the behavior of single-shear, laterally-loaded connections when loaded up to and beyond capacity (i.e., maximum resistance). Specimens included a wide array of connection configurations common in wood construction. All connections were tested monotonically in tension under displacement-controlled loading, parallel to the grain. Results of these tests are presented and discussed. Test variables of nailed connections included nail diameter, side member material type, and side member thickness. Test variables of bolted connections included bolt diameter, commercial species grouping of the main and side members, and main member thickness. Conclusions drawn from this research include mechanics-based explanations of numerous connection response trends observed with respect to test variables. Additionally, observed factors of safety and over-strengths of current design values are quantified on a capacity-basis.","abstract_has_math":false,"creators":["Smart, Jason Vincent"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Loferski, Joseph R.","Dolan, James Daniel"],"committee_members":["Cousins, Thomas E."],"year":2002,"date_issued":"2002-07-01","date_published":"2002-07-01","updated_at":"2026-07-22T22:19:53Z","subjects":["Wood Connections","Monotonic Loading","Capacity-Based Design"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01092003-210244"],"render_values":[{"text":"etd-01092003-210244","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/30863","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Loferski, Joseph R.","Dolan, James Daniel"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cousins, Thomas E."]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Smart, Jason Vincent"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:30:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:30:19Z","2004-01-16"]},{"key":"dc:date.issued","label":"Date","values":["2002-07-01"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wood Connections","Monotonic Loading","Capacity-Based Design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01092003-210244"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/30863"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The experimental study reported upon in this thesis focused on the development of physical data characterizing the behavior of single-shear, laterally-loaded connections when loaded up to and beyond capacity (i.e., maximum resistance). Specimens included a wide array of connection configurations common in wood construction. All connections were tested monotonically in tension under displacement-controlled loading, parallel to the grain. Results of these tests are presented and discussed. Test variables of nailed connections included nail diameter, side member material type, and side member thickness. Test variables of bolted connections included bolt diameter, commercial species grouping of the main and side members, and main member thickness. Conclusions drawn from this research include mechanics-based explanations of numerous connection response trends observed with respect to test variables. Additionally, observed factors of safety and over-strengths of current design values are quantified on a capacity-basis."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Capacity Resistance and Performance of Single-Shear Bolted and Nailed Connections: An Experimental Investigation"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Loferski, Joseph R.","Dolan, James Daniel"],"dc:contributor.committeemember":["Cousins, Thomas E."],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Smart, Jason Vincent"],"dc:date.accessioned":["2014-03-14T20:30:19Z"],"dc:date.available":["2014-03-14T20:30:19Z","2004-01-16"],"dc:date.issued":["2002-07-01"],"dc:description.abstract":["The experimental study reported upon in this thesis focused on the development of physical data characterizing the behavior of single-shear, laterally-loaded connections when loaded up to and beyond capacity (i.e., maximum resistance). Specimens included a wide array of connection configurations common in wood construction. All connections were tested monotonically in tension under displacement-controlled loading, parallel to the grain. Results of these tests are presented and discussed. Test variables of nailed connections included nail diameter, side member material type, and side member thickness. Test variables of bolted connections included bolt diameter, commercial species grouping of the main and side members, and main member thickness. Conclusions drawn from this research include mechanics-based explanations of numerous connection response trends observed with respect to test variables. Additionally, observed factors of safety and over-strengths of current design values are quantified on a capacity-basis."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-01092003-210244"],"dc:identifier.uri":["http://hdl.handle.net/10919/30863"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Wood Connections","Monotonic Loading","Capacity-Based Design"],"dc:title":["Capacity Resistance and Performance of Single-Shear Bolted and Nailed Connections: An Experimental Investigation"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:53Z"}