{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/30131"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/30131","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Methodology for a Security-Dependability Adaptive Protection Scheme based on Data Mining","abstract":"The power industry is currently in the process of re-inventing itself. The unbundling of the traditional monopolistic structure that gave birth to a deregulated electricity market, the mass tendency towards a greener use of energy, the new emphasis on distributed generation and alternative renewable resources, and new emerging technologies have revolutionized the century old industry. Recent blackouts offer testimonies of the crucial role played by protection relays in a reliable power system. It is argued that embracing the paradigm shift of adaptive protection is a fundamental step towards a reliable power grid. The adaptive philosophy of protection systems acknowledges that relays may change their characteristics in order to tailor their operation to prevailing system conditions. The purpose of this dissertation is to present methodology to implement a security/dependability adaptive protection scheme. It is argued that the likelihood of hidden failures and potential cascading events can be significantly reduced by adjusting the security/dependability balance of protection systems to better suit prevailing system conditions. The proposed methodology is based on Wide Area Measurements (WAMs) obtained with the aid of Phasor Measurement Units (PMUs). A Data Mining algorithm known as Decision Trees is used to classify the power system state and to predict the optimal security/dependability bias of a critical protection scheme.","abstract_html":"The power industry is currently in the process of re-inventing itself. The unbundling of the traditional monopolistic structure that gave birth to a deregulated electricity market, the mass tendency towards a greener use of energy, the new emphasis on distributed generation and alternative renewable resources, and new emerging technologies have revolutionized the century old industry. Recent blackouts offer testimonies of the crucial role played by protection relays in a reliable power system. It is argued that embracing the paradigm shift of adaptive protection is a fundamental step towards a reliable power grid. The adaptive philosophy of protection systems acknowledges that relays may change their characteristics in order to tailor their operation to prevailing system conditions. The purpose of this dissertation is to present methodology to implement a security/dependability adaptive protection scheme. It is argued that the likelihood of hidden failures and potential cascading events can be significantly reduced by adjusting the security/dependability balance of protection systems to better suit prevailing system conditions. The proposed methodology is based on Wide Area Measurements (WAMs) obtained with the aid of Phasor Measurement Units (PMUs). A Data Mining algorithm known as Decision Trees is used to classify the power system state and to predict the optimal security/dependability bias of a critical protection scheme.","abstract_has_math":false,"creators":["Bernabeu, Emanuel"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Thorp, James S.","Centeno, Virgilio A."],"committee_members":["De La Ree, Jaime","DaSilva, Luiz A.","Kohler, Werner E.","Liu, Yilu"],"year":2009,"date_issued":"2009-12-09","date_published":"2009-12-09","updated_at":"2026-07-22T22:20:29Z","subjects":["wide area measurements","data mining","decision trees","adaptive protection","critical locations"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12172009-201325"],"render_values":[{"text":"etd-12172009-201325","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/30131","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Thorp, James S.","Centeno, Virgilio A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["De La Ree, Jaime","DaSilva, Luiz A.","Kohler, Werner E.","Liu, Yilu"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Bernabeu, Emanuel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:20:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:20:48Z","2010-01-21"]},{"key":"dc:date.issued","label":"Date","values":["2009-12-09"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["wide area measurements","data mining","decision trees","adaptive protection","critical locations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12172009-201325"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/30131"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The power industry is currently in the process of re-inventing itself. The unbundling of the traditional monopolistic structure that gave birth to a deregulated electricity market, the mass tendency towards a greener use of energy, the new emphasis on distributed generation and alternative renewable resources, and new emerging technologies have revolutionized the century old industry. Recent blackouts offer testimonies of the crucial role played by protection relays in a reliable power system. It is argued that embracing the paradigm shift of adaptive protection is a fundamental step towards a reliable power grid. The adaptive philosophy of protection systems acknowledges that relays may change their characteristics in order to tailor their operation to prevailing system conditions. The purpose of this dissertation is to present methodology to implement a security/dependability adaptive protection scheme. It is argued that the likelihood of hidden failures and potential cascading events can be significantly reduced by adjusting the security/dependability balance of protection systems to better suit prevailing system conditions. The proposed methodology is based on Wide Area Measurements (WAMs) obtained with the aid of Phasor Measurement Units (PMUs). A Data Mining algorithm known as Decision Trees is used to classify the power system state and to predict the optimal security/dependability bias of a critical protection scheme."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:title","label":"Title","values":["Methodology for a Security-Dependability Adaptive Protection Scheme based on Data Mining"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Thorp, James S.","Centeno, Virgilio A."],"dc:contributor.committeemember":["De La Ree, Jaime","DaSilva, Luiz A.","Kohler, Werner E.","Liu, Yilu"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Bernabeu, Emanuel"],"dc:date.accessioned":["2014-03-14T20:20:48Z"],"dc:date.available":["2014-03-14T20:20:48Z","2010-01-21"],"dc:date.issued":["2009-12-09"],"dc:description.abstract":["The power industry is currently in the process of re-inventing itself. The unbundling of the traditional monopolistic structure that gave birth to a deregulated electricity market, the mass tendency towards a greener use of energy, the new emphasis on distributed generation and alternative renewable resources, and new emerging technologies have revolutionized the century old industry. Recent blackouts offer testimonies of the crucial role played by protection relays in a reliable power system. It is argued that embracing the paradigm shift of adaptive protection is a fundamental step towards a reliable power grid. The adaptive philosophy of protection systems acknowledges that relays may change their characteristics in order to tailor their operation to prevailing system conditions. The purpose of this dissertation is to present methodology to implement a security/dependability adaptive protection scheme. It is argued that the likelihood of hidden failures and potential cascading events can be significantly reduced by adjusting the security/dependability balance of protection systems to better suit prevailing system conditions. The proposed methodology is based on Wide Area Measurements (WAMs) obtained with the aid of Phasor Measurement Units (PMUs). A Data Mining algorithm known as Decision Trees is used to classify the power system state and to predict the optimal security/dependability bias of a critical protection scheme."],"dc:description.degree":["Ph. D."],"dc:identifier.other":["etd-12172009-201325"],"dc:identifier.uri":["http://hdl.handle.net/10919/30131"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["wide area measurements","data mining","decision trees","adaptive protection","critical locations"],"dc:title":["Methodology for a Security-Dependability Adaptive Protection Scheme based on Data Mining"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:29Z"}