{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/29956"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/29956","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Uncertainty and Confidence Intervals of the Monte Carlo Ray-Trace Method in Radiation Heat Transfer","abstract":"The primary objective of the work reported here is to develop a methodology to predict the uncertainty associated with radiation heat transfer problems solved using the Monte Carlo ray-trace method (MCRT). Four equations are developed to predict the uncertainty of the distribution factor from one surface to another, the global uncertainty of all the distribution factors in an enclosure, the uncertainty of the net heat flux from a surface, and the global uncertainty of the net heat flux from all the surfaces in an enclosure, respectively. Numerical experiments are performed to successfully validate these equations and to study the impact of various parameters such as the number of surfaces in an enclosure, the number of energy bundles traced in the MCRT model, the fractional uncertainty of emissivity and temperature, and the temperature distribution in the enclosure. Finally, the methodology is successfully applied to a detailed MCRT model of a CERES-like radiometer.","abstract_html":"The primary objective of the work reported here is to develop a methodology to predict the uncertainty associated with radiation heat transfer problems solved using the Monte Carlo ray-trace method (MCRT). Four equations are developed to predict the uncertainty of the distribution factor from one surface to another, the global uncertainty of all the distribution factors in an enclosure, the uncertainty of the net heat flux from a surface, and the global uncertainty of the net heat flux from all the surfaces in an enclosure, respectively. Numerical experiments are performed to successfully validate these equations and to study the impact of various parameters such as the number of surfaces in an enclosure, the number of energy bundles traced in the MCRT model, the fractional uncertainty of emissivity and temperature, and the temperature distribution in the enclosure. Finally, the methodology is successfully applied to a detailed MCRT model of a CERES-like radiometer.","abstract_has_math":false,"creators":["Sanchez, Maria Cristina"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Mahan, James Robert"],"committee_members":["Day, Martin V.","Priestley, Kory J.","Thole, Karen A.","Scott, Elaine P."],"year":2002,"date_issued":"2002-11-15","date_published":"2002-11-15","updated_at":"2026-07-22T22:19:54Z","subjects":["Monte Carlo ray-trace method","thermal radiation","uncertainty analysis"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12062002-211117"],"render_values":[{"text":"etd-12062002-211117","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/29956","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Mahan, James Robert"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Day, Martin V.","Priestley, Kory J.","Thole, Karen A.","Scott, Elaine P."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Sanchez, Maria Cristina"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:19:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:19:52Z","2003-12-13"]},{"key":"dc:date.issued","label":"Date","values":["2002-11-15"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Monte Carlo ray-trace method","thermal radiation","uncertainty analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12062002-211117"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/29956"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary objective of the work reported here is to develop a methodology to predict the uncertainty associated with radiation heat transfer problems solved using the Monte Carlo ray-trace method (MCRT). Four equations are developed to predict the uncertainty of the distribution factor from one surface to another, the global uncertainty of all the distribution factors in an enclosure, the uncertainty of the net heat flux from a surface, and the global uncertainty of the net heat flux from all the surfaces in an enclosure, respectively. Numerical experiments are performed to successfully validate these equations and to study the impact of various parameters such as the number of surfaces in an enclosure, the number of energy bundles traced in the MCRT model, the fractional uncertainty of emissivity and temperature, and the temperature distribution in the enclosure. Finally, the methodology is successfully applied to a detailed MCRT model of a CERES-like radiometer."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:title","label":"Title","values":["Uncertainty and Confidence Intervals of the Monte Carlo Ray-Trace Method in Radiation Heat Transfer"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Mahan, James Robert"],"dc:contributor.committeemember":["Day, Martin V.","Priestley, Kory J.","Thole, Karen A.","Scott, Elaine P."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Sanchez, Maria Cristina"],"dc:date.accessioned":["2014-03-14T20:19:52Z"],"dc:date.available":["2014-03-14T20:19:52Z","2003-12-13"],"dc:date.issued":["2002-11-15"],"dc:description.abstract":["The primary objective of the work reported here is to develop a methodology to predict the uncertainty associated with radiation heat transfer problems solved using the Monte Carlo ray-trace method (MCRT). Four equations are developed to predict the uncertainty of the distribution factor from one surface to another, the global uncertainty of all the distribution factors in an enclosure, the uncertainty of the net heat flux from a surface, and the global uncertainty of the net heat flux from all the surfaces in an enclosure, respectively. Numerical experiments are performed to successfully validate these equations and to study the impact of various parameters such as the number of surfaces in an enclosure, the number of energy bundles traced in the MCRT model, the fractional uncertainty of emissivity and temperature, and the temperature distribution in the enclosure. Finally, the methodology is successfully applied to a detailed MCRT model of a CERES-like radiometer."],"dc:description.degree":["Ph. D."],"dc:identifier.other":["etd-12062002-211117"],"dc:identifier.uri":["http://hdl.handle.net/10919/29956"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Monte Carlo ray-trace method","thermal radiation","uncertainty analysis"],"dc:title":["Uncertainty and Confidence Intervals of the Monte Carlo Ray-Trace Method in Radiation Heat Transfer"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:54Z"}