Back to results

Virginia Tech

Chromatographic Properties of Silica-Based Monolithic HPLC Columns

Abstract

dc:description.abstract

Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of porous silica. The main advantage of such a network is decreased backpressure due to macropores (2 μM) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The Chromolith SpeedROD™ (EM Science, Gibbstown NJ) is a commercially available silica-based monolithic column. This work investigated the chromatographic properties of the 50x4.60 mm (ODS) SpeedROD™. Data fit to the van Deemter equation (mean square error=0.834) indicated that the van Deemter model was valid for monolithic columns. An effective particle size of 4 μM for the SpeedROD™ column was assigned by comparing the minimum of van Deemter curves with a series of particulate columns having various particle diameters. Separation Impedance (E), an empirically derived measure of column performance, was calculated as an alternate method of evaluating column efficiency. Data collected using this model confirmed monolithic columns behaves as a (more efficient) 3 μM column. A series of experiments were designed to compare the effects of mobile phase strength and mobile phase viscosity between the SpeedROD™ column and a particulate column. The results indicated both solvent strength and viscosity have effects on the monolithic column at the optimum linear velocity. A fast (90 s) HPLC method was developed using the SpeedROD™ column and a seven-component test mixture with a large range of hydrophobicities. The precision for both retention time and peak area was measured at high linear velocities (8 mL/min) and the percent relative standard deviation (RSD) calculated. Column to column reproducibility (n=6) was measured. The overall percent RSD ranged from 0.25% to 4.56% for retention time and from 1.08% to 6.77% for peak area. Run to run reproducibility (n=15) was measured for all six columns. Averages ranged for retention time from 0.89% to 5.09% RSD and for peak area from 4.65% to 6.18% RSD. Applications for the SpeedROD™ column with various sample types were developed and discussed. These methods demonstrated the effectiveness of the SpeedROD™ at fast flow rates.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemistry
Department dc:contributor.department
Chemistry
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2002

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smith, Jennifer Houston
Chair dc:contributor.committeechair
  • McNair, Harold M.
Committee members dc:contributor.committeemember
  • Viers, Jimmy W.
  • Anderson, Mark R.
  • Glanville, James O.
  • Taylor, Larry T.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-12062002-051420
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/29953

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Smith, Jennifer Houston. Chromatographic Properties of Silica-Based Monolithic HPLC Columns. doctoral thesis, Virginia Tech, 2002. http://hdl.handle.net/10919/29953