Effects of Bottom Chord Extensions on the Static and Dynamic Performance of Steel Joist Supported Floors

Abstract

dc:description.abstract

The purpose of this study was to examine the effect of bottom chord extensions on deflections and vibration characteristics of joist supported floor systems when joist bottom chord extensions are installed. To understand the effect of bottom chord extensions on deflections, natural frequency, damping, mode shape and effective mass, extensive analytical and experimental studies were conducted on single span and three span joist supported laboratory footbridges with different bottom chord extension configurations. Finite element computer models were created to simulate and compare the results of stiffness and vibration tests. Testing was done with a) the bottom chord extensions in-place before the concrete was placed, b) with all or part of the bottom chord extensions removed, and c) after the bottom chord extensions had been reinstalled with jacking for the single span footbridge and without jacking for the three-span footbridge. Results from the stiffness tests indicate that re-installing the bottom chord extensions to the joists of the single span footbridge with cured concrete with the center of the span raised helps to reduce the uniform load deflections to some extent, but not as much as placing the bottom chord extensions before the concrete placement. Likewise, for the three span footbridge, placing the bottom chord extensions before the concrete placement is observed to be a better solution. Results from the dynamic tests indicate that the effect of bottom chord extensions on the single span footbridge is consistent for natural frequency, 20 psf live load deflections, sinusoidal excitations with high amplitudes, quarter point heel drop excitations, walking excitations, and effective mass values. The effect of bottom chord extensions on the three span footbridge is consistent for the natural frequency and 20 psf deflections. However, the FRF (Frequency Response Function) peaks of chirp, heel drop, sinusoidal excitations, accelerations from walking data, and the MEScope and Finite Element model effective mass results do not follow a common trend. It can be concluded that even though the footbridge was stiffened by the bottom chord extensions, that does not necessarily mean that the acceleration levels, and hence the frequency response function peaks, decrease. However, bottom chord extensions do increase the natural frequencies for all the three governing bending modes.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Avci, Onur
Chairs dc:contributor.committeechair
  • Setareh, Mehdi
  • Murray, Thomas M.
Committee members dc:contributor.committeemember
  • Charney, Finley A.
  • Plaut, Raymond H.
  • Wicks, Alfred L.

Subjects

dc:subject × 16

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-11022005-232019
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/29432

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Avci, Onur. Effects of Bottom Chord Extensions on the Static and Dynamic Performance of Steel Joist Supported Floors. doctoral thesis, Virginia Tech, 2005. http://hdl.handle.net/10919/29432