{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/29305"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/29305","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Chemical Micro Preconcentrators Development for Micro Gas Chromatography Systems","abstract":"Microelectromechanical systems (MEMS) technology allows the realization of mechanical parts, sensors, actuators and electronics on silicon substrate. An attractive utilization of MEMS is to develop micro instruments for chemical analysis. An example is gas chromatography (GC) which is widely used in food, environmental, pharmaceutical, petroleum/refining, forensic/security, and flavors and fragrances industries. A MEMS-based micro GC (ÂµGC) provides capabilities for quantitative analysis of complex chemical mixtures in the field with very short analysis time and small amounts of consumables. The aim of this research effort is to enhance the sensitivity and selectivity of ÂµGC instruments by implementing chemical amplification method known as preconcentration. A micro preconcentrator (ÂµPC) extracts the target analytes from the sample matrix, concentrates them, and injects them into the separation column for analysis. This work resulted in the development of silicon-glass bonded chips consisting of 7 mm x 7 mm x 0.38 mm multiport cavity with thousands of embedded 3D microstructures (to achieve high surface-to-volume ratio) coated with polymeric thin film adsorbents. Deep reactive ion etching (DRIE) was the enabling technology for the realization of ÂµPCs. Several coating methods, such as inkjet printing of polymers and polymer precipitation from solution have been utilized to coat complex geometrical structures. One major outcome was the development of cobweb adsorbent structure. Moreover, the porous polymeric adsorbent Tenax TA in the film form was characterized, for the first time, for Î¼PC application and shown to have similar properties to that of the granular form. Several Î¼PC designs were experimentally evaluated for their performance in concentrating volatile organic compounds, including cancer biomarkers, Propofol (anesthetic agent), environmental pollutants, and chemical warfare simulants. The possibility of utilizing the Î¼PCs in practical applications such breath analysis was also demonstrated.","abstract_html":"Microelectromechanical systems (MEMS) technology allows the realization of mechanical parts, sensors, actuators and electronics on silicon substrate. An attractive utilization of MEMS is to develop micro instruments for chemical analysis. An example is gas chromatography (GC) which is widely used in food, environmental, pharmaceutical, petroleum/refining, forensic/security, and flavors and fragrances industries. A MEMS-based micro GC (ÂµGC) provides capabilities for quantitative analysis of complex chemical mixtures in the field with very short analysis time and small amounts of consumables. The aim of this research effort is to enhance the sensitivity and selectivity of ÂµGC instruments by implementing chemical amplification method known as preconcentration. A micro preconcentrator (ÂµPC) extracts the target analytes from the sample matrix, concentrates them, and injects them into the separation column for analysis. This work resulted in the development of silicon-glass bonded chips consisting of 7 mm x 7 mm x 0.38 mm multiport cavity with thousands of embedded 3D microstructures (to achieve high surface-to-volume ratio) coated with polymeric thin film adsorbents. Deep reactive ion etching (DRIE) was the enabling technology for the realization of ÂµPCs. Several coating methods, such as inkjet printing of polymers and polymer precipitation from solution have been utilized to coat complex geometrical structures. One major outcome was the development of cobweb adsorbent structure. Moreover, the porous polymeric adsorbent Tenax TA in the film form was characterized, for the first time, for Î¼PC application and shown to have similar properties to that of the granular form. Several Î¼PC designs were experimentally evaluated for their performance in concentrating volatile organic compounds, including cancer biomarkers, Propofol (anesthetic agent), environmental pollutants, and chemical warfare simulants. The possibility of utilizing the Î¼PCs in practical applications such breath analysis was also demonstrated.","abstract_has_math":false,"creators":["Alfeeli, Bassam"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Agah, Masoud"],"committee_members":["Taylor, Larry T.","Hendricks, Robert W.","Wang, Anbo","Meehan, Kathleen"],"year":2010,"date_issued":"2010-10-06","date_published":"2010-10-06","updated_at":"2026-07-22T22:18:41Z","subjects":["Handheld Chemical Analysis","Micro Analytical Systems","Breath Analysis","Sample Pretreatment","MEMS","Tenax TA Films","Microfabrication","DRIE"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10182010-121942"],"render_values":[{"text":"etd-10182010-121942","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/29305","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Agah, Masoud"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Taylor, Larry T.","Hendricks, Robert W.","Wang, Anbo","Meehan, Kathleen"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Alfeeli, Bassam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:17:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:17:27Z","2010-11-29"]},{"key":"dc:date.issued","label":"Date","values":["2010-10-06"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Handheld Chemical Analysis","Micro Analytical Systems","Breath Analysis","Sample Pretreatment","MEMS","Tenax TA Films","Microfabrication","DRIE"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10182010-121942"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/29305"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microelectromechanical systems (MEMS) technology allows the realization of mechanical parts, sensors, actuators and electronics on silicon substrate. An attractive utilization of MEMS is to develop micro instruments for chemical analysis. An example is gas chromatography (GC) which is widely used in food, environmental, pharmaceutical, petroleum/refining, forensic/security, and flavors and fragrances industries. A MEMS-based micro GC (ÂµGC) provides capabilities for quantitative analysis of complex chemical mixtures in the field with very short analysis time and small amounts of consumables. The aim of this research effort is to enhance the sensitivity and selectivity of ÂµGC instruments by implementing chemical amplification method known as preconcentration. A micro preconcentrator (ÂµPC) extracts the target analytes from the sample matrix, concentrates them, and injects them into the separation column for analysis. This work resulted in the development of silicon-glass bonded chips consisting of 7 mm x 7 mm x 0.38 mm multiport cavity with thousands of embedded 3D microstructures (to achieve high surface-to-volume ratio) coated with polymeric thin film adsorbents. Deep reactive ion etching (DRIE) was the enabling technology for the realization of ÂµPCs. Several coating methods, such as inkjet printing of polymers and polymer precipitation from solution have been utilized to coat complex geometrical structures. One major outcome was the development of cobweb adsorbent structure. Moreover, the porous polymeric adsorbent Tenax TA in the film form was characterized, for the first time, for Î¼PC application and shown to have similar properties to that of the granular form. Several Î¼PC designs were experimentally evaluated for their performance in concentrating volatile organic compounds, including cancer biomarkers, Propofol (anesthetic agent), environmental pollutants, and chemical warfare simulants. The possibility of utilizing the Î¼PCs in practical applications such breath analysis was also demonstrated."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:title","label":"Title","values":["Chemical Micro Preconcentrators Development for Micro Gas Chromatography Systems"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Agah, Masoud"],"dc:contributor.committeemember":["Taylor, Larry T.","Hendricks, Robert W.","Wang, Anbo","Meehan, Kathleen"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Alfeeli, Bassam"],"dc:date.accessioned":["2014-03-14T20:17:27Z"],"dc:date.available":["2014-03-14T20:17:27Z","2010-11-29"],"dc:date.issued":["2010-10-06"],"dc:description.abstract":["Microelectromechanical systems (MEMS) technology allows the realization of mechanical parts, sensors, actuators and electronics on silicon substrate. An attractive utilization of MEMS is to develop micro instruments for chemical analysis. An example is gas chromatography (GC) which is widely used in food, environmental, pharmaceutical, petroleum/refining, forensic/security, and flavors and fragrances industries. A MEMS-based micro GC (ÂµGC) provides capabilities for quantitative analysis of complex chemical mixtures in the field with very short analysis time and small amounts of consumables. The aim of this research effort is to enhance the sensitivity and selectivity of ÂµGC instruments by implementing chemical amplification method known as preconcentration. A micro preconcentrator (ÂµPC) extracts the target analytes from the sample matrix, concentrates them, and injects them into the separation column for analysis. This work resulted in the development of silicon-glass bonded chips consisting of 7 mm x 7 mm x 0.38 mm multiport cavity with thousands of embedded 3D microstructures (to achieve high surface-to-volume ratio) coated with polymeric thin film adsorbents. Deep reactive ion etching (DRIE) was the enabling technology for the realization of ÂµPCs. Several coating methods, such as inkjet printing of polymers and polymer precipitation from solution have been utilized to coat complex geometrical structures. One major outcome was the development of cobweb adsorbent structure. Moreover, the porous polymeric adsorbent Tenax TA in the film form was characterized, for the first time, for Î¼PC application and shown to have similar properties to that of the granular form. Several Î¼PC designs were experimentally evaluated for their performance in concentrating volatile organic compounds, including cancer biomarkers, Propofol (anesthetic agent), environmental pollutants, and chemical warfare simulants. The possibility of utilizing the Î¼PCs in practical applications such breath analysis was also demonstrated."],"dc:description.degree":["Ph. D."],"dc:identifier.other":["etd-10182010-121942"],"dc:identifier.uri":["http://hdl.handle.net/10919/29305"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Handheld Chemical Analysis","Micro Analytical Systems","Breath Analysis","Sample Pretreatment","MEMS","Tenax TA Films","Microfabrication","DRIE"],"dc:title":["Chemical Micro Preconcentrators Development for Micro Gas Chromatography Systems"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:18:41Z"}