{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/26790"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/26790","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Measurement of the Michel Parameter Rho Using the MEGA Positron Spectrometer","abstract":"This experiment attempts to measure the Michel parameter Rho in normal muon decay Mu to e nu_{e} nu_{mu} with a precision of 0.001. The Standard Model with pure V-A interaction gives 0.75 for this parameter. The world average value is 0.7518 +/- 0.0026. A deviation of the value of Rho from 0.75 will indicate new physics. The experiment, RHO, was carried out at the Los Alamos Meson Physics Facility (LAMPF) of Los Alamos National Laboratory (LANL) in New Mexico, USA, in 1993. The existing experimental set-up that was built for the MEGA experiment was used for the RHO measurement. The experiment was a collaboration of about 50 physicists from Los Alamos National Laboratory, Stanford University, Fermi National Accelerator Laboratory, Virginia Tech, Texas A University, Indiana University, Valparaiso University, University of Houston, University of Chicago and University of Virginia. The result of the experiment is in agreement with Standard Model. The precision of this measurement was dominated by systematic uncertainties due to the fact that the positron spectrometer used in the measurement was designed for another experiment. Thus, the data analysis here focused mainly on the determination of systematic errors.","abstract_html":"This experiment attempts to measure the Michel parameter Rho in normal muon decay Mu to e nu_{e} nu_{mu} with a precision of 0.001. The Standard Model with pure V-A interaction gives 0.75 for this parameter. The world average value is 0.7518 +/- 0.0026. A deviation of the value of Rho from 0.75 will indicate new physics. The experiment, RHO, was carried out at the Los Alamos Meson Physics Facility (LAMPF) of Los Alamos National Laboratory (LANL) in New Mexico, USA, in 1993. The existing experimental set-up that was built for the MEGA experiment was used for the RHO measurement. The experiment was a collaboration of about 50 physicists from Los Alamos National Laboratory, Stanford University, Fermi National Accelerator Laboratory, Virginia Tech, Texas A University, Indiana University, Valparaiso University, University of Houston, University of Chicago and University of Virginia. The result of the experiment is in agreement with Standard Model. The precision of this measurement was dominated by systematic uncertainties due to the fact that the positron spectrometer used in the measurement was designed for another experiment. Thus, the data analysis here focused mainly on the determination of systematic errors.","abstract_has_math":false,"creators":["Lee, Fei-sheng"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":[],"committee_chairs":["Piilonen, Leo E."],"committee_members":["Simonetti, John H.","Kinoshita, Kay","Abashian, Alexander","Chang, Lay Nam"],"year":2001,"date_issued":"2001-04-03","date_published":"2001-04-03","updated_at":"2026-07-22T22:19:27Z","subjects":["Standard Model","V-A Theory","Michel Parameter","Muon Decay"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04122001-101532"],"render_values":[{"text":"etd-04122001-101532","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/26790","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Piilonen, Leo E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Simonetti, John H.","Kinoshita, Kay","Abashian, Alexander","Chang, Lay Nam"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Lee, Fei-sheng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:09:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:09:26Z","2002-04-29"]},{"key":"dc:date.issued","label":"Date","values":["2001-04-03"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Standard Model","V-A Theory","Michel Parameter","Muon Decay"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04122001-101532"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/26790"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This experiment attempts to measure the Michel parameter Rho in normal muon decay Mu to e nu_{e} nu_{mu} with a precision of 0.001. The Standard Model with pure V-A interaction gives 0.75 for this parameter. The world average value is 0.7518 +/- 0.0026. A deviation of the value of Rho from 0.75 will indicate new physics. The experiment, RHO, was carried out at the Los Alamos Meson Physics Facility (LAMPF) of Los Alamos National Laboratory (LANL) in New Mexico, USA, in 1993. The existing experimental set-up that was built for the MEGA experiment was used for the RHO measurement. The experiment was a collaboration of about 50 physicists from Los Alamos National Laboratory, Stanford University, Fermi National Accelerator Laboratory, Virginia Tech, Texas A University, Indiana University, Valparaiso University, University of Houston, University of Chicago and University of Virginia. The result of the experiment is in agreement with Standard Model. The precision of this measurement was dominated by systematic uncertainties due to the fact that the positron spectrometer used in the measurement was designed for another experiment. Thus, the data analysis here focused mainly on the determination of systematic errors."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:title","label":"Title","values":["Measurement of the Michel Parameter Rho Using the MEGA Positron Spectrometer"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Piilonen, Leo E."],"dc:contributor.committeemember":["Simonetti, John H.","Kinoshita, Kay","Abashian, Alexander","Chang, Lay Nam"],"dc:contributor.department":["Physics"],"dc:creator":["Lee, Fei-sheng"],"dc:date.accessioned":["2014-03-14T20:09:26Z"],"dc:date.available":["2014-03-14T20:09:26Z","2002-04-29"],"dc:date.issued":["2001-04-03"],"dc:description.abstract":["This experiment attempts to measure the Michel parameter Rho in normal muon decay Mu to e nu_{e} nu_{mu} with a precision of 0.001. The Standard Model with pure V-A interaction gives 0.75 for this parameter. The world average value is 0.7518 +/- 0.0026. A deviation of the value of Rho from 0.75 will indicate new physics. The experiment, RHO, was carried out at the Los Alamos Meson Physics Facility (LAMPF) of Los Alamos National Laboratory (LANL) in New Mexico, USA, in 1993. The existing experimental set-up that was built for the MEGA experiment was used for the RHO measurement. The experiment was a collaboration of about 50 physicists from Los Alamos National Laboratory, Stanford University, Fermi National Accelerator Laboratory, Virginia Tech, Texas A University, Indiana University, Valparaiso University, University of Houston, University of Chicago and University of Virginia. The result of the experiment is in agreement with Standard Model. The precision of this measurement was dominated by systematic uncertainties due to the fact that the positron spectrometer used in the measurement was designed for another experiment. Thus, the data analysis here focused mainly on the determination of systematic errors."],"dc:description.degree":["Ph. D."],"dc:identifier.other":["etd-04122001-101532"],"dc:identifier.uri":["http://hdl.handle.net/10919/26790"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Standard Model","V-A Theory","Michel Parameter","Muon Decay"],"dc:title":["Measurement of the Michel Parameter Rho Using the MEGA Positron Spectrometer"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:27Z"}