Back to results

Virginia Tech

Improving Off-line and On-line Supercritical Fluid Extraction Techniques by Elevating the Post-Restrictor Pressure

Abstract

dc:description.abstract

The high flow rate that results as fluid decompresses through the restrictor is arguably the single greatest problem with supercritical fluid extraction techniques. As a result of these high flow rates, solvent trapping is not efficient in many cases, and the more complicated sorbent trapping technique must be used. In addition, loss of the collection solvent may occur during the process making it difficult to work with small volumes, which are desirable from the standpoint of sensitivity, cost, and environmental concerns. Similarly, these high decompressed flows have made it difficult to directly interface supercritical fluid extraction methods with separation techniques. This is unfortunate as supercritical extractions are ideal for on-line coupling in other respects, such as the fact that the fluid becomes gaseous upon depressurization and that supercritical fluids generally extract less contaminant material. In this thesis we have shown that, by elevating the post-restrictor pressure, the decompressed flow rate can be reduced, and these problems can be minimized, considerably. Off-line trapping becomes much simpler when working at elevated pressures as the need for sorbent trapping is virtually eliminated and solvent trapping may be conducted with much less difficulty. Elevated post-restrictor pressures were found to be very beneficial for on-line work as well. SFE/GC was carried out with complete transfer of the extraction effluent to a capillary GC column, which has not previously been demonstrated. Likewise the use of an open-tubular column interface, maintained at moderately elevated pressures, allowed SFE/HPLC to be conducted with quantitative analyte transfer, even in the presence of 10% modifier. In all cases - but especially for the on-line methods - more practical extraction parameters were possible, including extraction vessel volume, extraction flow rate, and dynamic extraction time. Another benefit of elevating the post-restrictor pressure is that higher extraction flow rates will generally be possible. The benefits of this were not evaluated in the research presented here, however, the effect that the extraction flow rate can have on extraction time is considered, from a theoretical standpoint, in Chapter five.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemistry
Department dc:contributor.department
Chemistry
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stone, Mark Adam
Chairs dc:contributor.committeechair
  • Taylor, Larry T.
  • McNair, Harold M.
Committee members dc:contributor.committeemember
  • Dorn, Harry C.
  • Viers, Jimmy W.
  • Tanko, James M.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-04042001-122603
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/26623

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Stone, Mark Adam. Improving Off-line and On-line Supercritical Fluid Extraction Techniques by Elevating the Post-Restrictor Pressure. doctoral thesis, Virginia Tech, 2001. http://hdl.handle.net/10919/26623