Back to results

Virginia Tech

A Comparison of Methods for Measuring Damage in Sucrose-Treated Medial Collateral Ligaments

Abstract

dc:description.abstract

The knee is the most complex joint in the human body. It consists of a system of muscle, bone, and ligaments that endures repetitive loading during daily and athletic activities. When this loading is excessive, damage to the knee occurs leading to a decreased quality of life.The medial collateral ligament (MCL) is one of the 4 major ligaments known to be commonly injured in the knee. The risk of injury to the knee joint increases with the elderly and individuals who experience chronic dehydration. For this reason, the focus of this study is to compare different mechanical quantities that can be used to analyze damage to the MCL. In this study, a novel mechanical testing protocol is used to progressively induce damage in dehydrated rat MCLs by performing tensile tests. This involves stretching the ligaments along their longitudinal axes to consecutive and increasing displacements starting at a 0.4 mm displacement and in increments of 0.2 mm until complete failure occurs. The load and change in length that the ligament experiences are measured at each displacement. Three different methods were evaluated to determine subfailure and damage propagation in rat MCLs: changes in tangent stiffness and chord stiffness, and changes in the load value at the 0.4 mm displacement for each load-displacement curve. The findings of this study indicate that the tangent stiffness and load at the 0.4 mm displacement provide information of the early onset of damage propagation. The decrease in chord stiffness of the ligament does not indicate damage progression in the ligament, but rather is the sign of the imminent failure of the MCL.This study provides insightful data into understanding the subfailure damage in the MCL.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Department dc:contributor.department
Biomedical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stewart, Victor A.
Chair dc:contributor.committeechair
  • De Vita, Raffaella
Committee members dc:contributor.committeemember
  • Madigan, Michael L.
  • Socha, John J.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:849
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/23110

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Stewart, Victor A.. A Comparison of Methods for Measuring Damage in Sucrose-Treated Medial Collateral Ligaments. masters thesis, Virginia Tech, 2013. http://hdl.handle.net/10919/23110