Back to results

Virginia Tech

Quantifying the Reliability of Performance Time and User Perceptions Obtained from Passive Exoskeleton Evaluations

Abstract

dc:description.abstract

Work-related musculoskeletal disorders (WMSDs) cost US industries billions annually and reduce quality of life for those afflicted. Passive exoskeletons (EXOs) have emerged as a potential intervention to reduce worker exposures to WMSD risk factors. As EXO adoption is rising, EXO manufacturers are designing and producing new EXOs in accordance with growing demand. However, there are no standardized EXO evaluation protocols and EXO use recommendations, due in part to insufficient information on the reliability of EXO evaluation measures. The purpose of this thesis was to quantify the reliability of common EXO evaluation measures, using both traditional approaches a more advanced statistical approach (i.e., Generalizability Theory), while also identifying potential effects of EXO type, work task, and individual differences. This work used data from a recently completed EXO evaluation study, conducted in Virginia Tech's Occupational Ergonomics and Biomechanics Lab. Forty-two total participants completed simulated occupational tasks, in two separate experimental sessions on different days, while using an arm-support EXO (ASE) and a back-support EXO (BSE). Several outcome measures reached excellent within-session reliability within four trials for many tasks considered. Between-session reliability levels were lower than within-session levels, with outcome measures reaching moderate-to-good reliability for most tasks. Interindividual differences accounted for the largest proportion of variance for measurement reliability, followed by the experimental session. For all tasks, outcome measures reached excellent dependability levels, with many achieving excellent levels within five total trials. Inconsistencies observed in between-session reliability levels and dependability levels suggest that additional training and EXO familiarity may affect measurement reliability of outcome measures differently for some tasks, unique to each EXO type. These discrepancies emphasize the importance for additional research into this topic. Overall, the current findings indicate that many of the commonly used EXO evaluation measures are reliable and dependable within five trials and one experimental session, providing a potential foundation for standardized EXO assessment protocols.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Industrial and Systems Engineering
Department dc:contributor.department
Industrial and Systems Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Noll, Alexander Baldrich Benoni
Chairs dc:contributor.committeechair
  • Nussbaum, Maury A.
  • Kim, Sun Wook
Committee members dc:contributor.committeemember
  • Madigan, Michael L.
  • Lim, Sol Ie

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:41232
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/120953

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Noll, Alexander Baldrich Benoni. Quantifying the Reliability of Performance Time and User Perceptions Obtained from Passive Exoskeleton Evaluations. masters thesis, Virginia Tech, 2024. https://hdl.handle.net/10919/120953