{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/120697"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/120697","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A passive microfluidic device for continuous buffer exchange","abstract":"Generally, dielectrophoresis (DEP) analysis of biological cell samples relies on the differing electrical parameters between the cells and the surrounding fluid medium. To achieve effective positive DEP manipulation and sorting of mammalian cells in suspension, it is required to resuspend the cells into a low-conductivity fluid buffer. The use of a low conductivity buffer also aids in minimizing the effects of Joule heating, which can cause cell death and ineffective cell trapping. The common method to prepare the sample relies on centrifugation of sensitive cells, a time-consuming and tedious process that may result in decreased sample viability. Herein is presented a microfluidic device that passively moves cells from a high-conductivity growth media into a low-conductivity DEP buffer. It is comprised of con- verging rows of pillars and uses mechanical filtration to force cells into the new buffer while allowing for the old fluid to flow through the posts and out of separate outlets. Because this device is intended to be used upstream of a contactless dielectrophoresis (cDEP) device, the buffer exchange device must have an outlet flow rate that is within the range necessary for direct integration with the cDEP device, maintain a low shear stress that will not affect the integrity of the sample and achieve sufficiently high cell recovery. Methods of this project included optimizing the shape, size, and orientation of the posts, determining the flow rate for maintaining an ideal DEP buffer conductivity, numerical modeling of shear stress, and determining the cell recovery rate. It is anticipated that this device can be extended to physiological media sample processing such as for liquid biopsy.","abstract_html":"Generally, dielectrophoresis (DEP) analysis of biological cell samples relies on the differing electrical parameters between the cells and the surrounding fluid medium. To achieve effective positive DEP manipulation and sorting of mammalian cells in suspension, it is required to resuspend the cells into a low-conductivity fluid buffer. The use of a low conductivity buffer also aids in minimizing the effects of Joule heating, which can cause cell death and ineffective cell trapping. The common method to prepare the sample relies on centrifugation of sensitive cells, a time-consuming and tedious process that may result in decreased sample viability. Herein is presented a microfluidic device that passively moves cells from a high-conductivity growth media into a low-conductivity DEP buffer. It is comprised of con- verging rows of pillars and uses mechanical filtration to force cells into the new buffer while allowing for the old fluid to flow through the posts and out of separate outlets. Because this device is intended to be used upstream of a contactless dielectrophoresis (cDEP) device, the buffer exchange device must have an outlet flow rate that is within the range necessary for direct integration with the cDEP device, maintain a low shear stress that will not affect the integrity of the sample and achieve sufficiently high cell recovery. Methods of this project included optimizing the shape, size, and orientation of the posts, determining the flow rate for maintaining an ideal DEP buffer conductivity, numerical modeling of shear stress, and determining the cell recovery rate. It is anticipated that this device can be extended to physiological media sample processing such as for liquid biopsy.","abstract_has_math":false,"creators":["Gedra, Olivia Rose"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":"Department of Biomedical Engineering and Mechanics","school":null,"contributors":[],"advisors":[],"committee_chairs":["Stremler, Mark A.","Davalos, Rafael V."],"committee_members":["Staples, Anne E."],"year":2024,"date_issued":"2024-07-25","date_published":"2024-07-25","updated_at":"2026-07-22T22:18:39Z","subjects":["Microfluidics","Buffer Exchange","Dielectrophoresis"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:41185"],"render_values":[{"text":"vt_gsexam:41185","href":null,"code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10919/120697","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Stremler, Mark A.","Davalos, Rafael V."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Staples, Anne E."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Biomedical Engineering and Mechanics"]},{"key":"dc:creator","label":"Author","values":["Gedra, Olivia Rose"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-07-26T08:00:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-07-26T08:00:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-07-25"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidics","Buffer Exchange","Dielectrophoresis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:41185"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/120697"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Generally, dielectrophoresis (DEP) analysis of biological cell samples relies on the differing electrical parameters between the cells and the surrounding fluid medium. To achieve effective positive DEP manipulation and sorting of mammalian cells in suspension, it is required to resuspend the cells into a low-conductivity fluid buffer. The use of a low conductivity buffer also aids in minimizing the effects of Joule heating, which can cause cell death and ineffective cell trapping. The common method to prepare the sample relies on centrifugation of sensitive cells, a time-consuming and tedious process that may result in decreased sample viability. Herein is presented a microfluidic device that passively moves cells from a high-conductivity growth media into a low-conductivity DEP buffer. It is comprised of con- verging rows of pillars and uses mechanical filtration to force cells into the new buffer while allowing for the old fluid to flow through the posts and out of separate outlets. Because this device is intended to be used upstream of a contactless dielectrophoresis (cDEP) device, the buffer exchange device must have an outlet flow rate that is within the range necessary for direct integration with the cDEP device, maintain a low shear stress that will not affect the integrity of the sample and achieve sufficiently high cell recovery. Methods of this project included optimizing the shape, size, and orientation of the posts, determining the flow rate for maintaining an ideal DEP buffer conductivity, numerical modeling of shear stress, and determining the cell recovery rate. It is anticipated that this device can be extended to physiological media sample processing such as for liquid biopsy."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["In order to accomplish numerous biomedical experiments, cells must be transferred from their native fluid growth media into a different fluid solution, through a process referred to as buffer exchange. The current method for buffer exchange is time consuming, tedious, and affects the number of cells left alive for experimentation. In this work, we present a microfluidic device that can accomplish the buffer exchange process by simply flowing in the cells in their media in parallel with the new buffer solution. The results of this research work can be extended to aid in the process of buffer exchange for various biological experiments. The proposed device utilizes mechanical filtration to force cells into the new buffer while allowing for the old fluid to flow through the posts and out of separate outlets. The design of the device was optimized through computational analysis of the concentration and fluid shear stress in conjunction with experimental tests of devices for outlet conductivity and cell retention."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["A passive microfluidic device for continuous buffer exchange"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Stremler, Mark A.","Davalos, Rafael V."],"dc:contributor.committeemember":["Staples, Anne E."],"dc:contributor.department":["Department of Biomedical Engineering and Mechanics"],"dc:creator":["Gedra, Olivia Rose"],"dc:date.accessioned":["2024-07-26T08:00:12Z"],"dc:date.available":["2024-07-26T08:00:12Z"],"dc:date.issued":["2024-07-25"],"dc:description.abstract":["Generally, dielectrophoresis (DEP) analysis of biological cell samples relies on the differing electrical parameters between the cells and the surrounding fluid medium. To achieve effective positive DEP manipulation and sorting of mammalian cells in suspension, it is required to resuspend the cells into a low-conductivity fluid buffer. The use of a low conductivity buffer also aids in minimizing the effects of Joule heating, which can cause cell death and ineffective cell trapping. The common method to prepare the sample relies on centrifugation of sensitive cells, a time-consuming and tedious process that may result in decreased sample viability. Herein is presented a microfluidic device that passively moves cells from a high-conductivity growth media into a low-conductivity DEP buffer. It is comprised of con- verging rows of pillars and uses mechanical filtration to force cells into the new buffer while allowing for the old fluid to flow through the posts and out of separate outlets. Because this device is intended to be used upstream of a contactless dielectrophoresis (cDEP) device, the buffer exchange device must have an outlet flow rate that is within the range necessary for direct integration with the cDEP device, maintain a low shear stress that will not affect the integrity of the sample and achieve sufficiently high cell recovery. Methods of this project included optimizing the shape, size, and orientation of the posts, determining the flow rate for maintaining an ideal DEP buffer conductivity, numerical modeling of shear stress, and determining the cell recovery rate. It is anticipated that this device can be extended to physiological media sample processing such as for liquid biopsy."],"dc:description.abstractgeneral":["In order to accomplish numerous biomedical experiments, cells must be transferred from their native fluid growth media into a different fluid solution, through a process referred to as buffer exchange. The current method for buffer exchange is time consuming, tedious, and affects the number of cells left alive for experimentation. In this work, we present a microfluidic device that can accomplish the buffer exchange process by simply flowing in the cells in their media in parallel with the new buffer solution. The results of this research work can be extended to aid in the process of buffer exchange for various biological experiments. The proposed device utilizes mechanical filtration to force cells into the new buffer while allowing for the old fluid to flow through the posts and out of separate outlets. The design of the device was optimized through computational analysis of the concentration and fluid shear stress in conjunction with experimental tests of devices for outlet conductivity and cell retention."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:41185"],"dc:identifier.uri":["https://hdl.handle.net/10919/120697"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Microfluidics","Buffer Exchange","Dielectrophoresis"],"dc:title":["A passive microfluidic device for continuous buffer exchange"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:18:39Z"}