{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/117281"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/117281","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The Development of Novel Apparatus, Systems, and Methods for Non-Invasive Thermal Interrogation (NITI)","abstract":"Non-Invasive Thermal Interrogation (NITI) is a form of non-destructive testing (NDT) that uses simultaneous measurements of object surface heat flux and object surface temperature. When these measurements are combined with signal processing algorithms, such as parameter estimation routines or other techniques, they can be used to non-invasively determine the internal temperature and parameters of the object in real-time. Consequently, NITI has a number of applications in the, for example, bio-medical, industrial, food safety, and wearable industries. The purpose of this Dissertation is to document the conceptualization and development of practical methods of Non-Invasive Thermal Interrogation (NITI) as pertains to a few example and non-limiting applications. This includes the design of novel NITI sensor technology and apparatus as well as different signal processing and interrogation techniques.","abstract_html":"Non-Invasive Thermal Interrogation (NITI) is a form of non-destructive testing (NDT) that uses simultaneous measurements of object surface heat flux and object surface temperature. When these measurements are combined with signal processing algorithms, such as parameter estimation routines or other techniques, they can be used to non-invasively determine the internal temperature and parameters of the object in real-time. Consequently, NITI has a number of applications in the, for example, bio-medical, industrial, food safety, and wearable industries. The purpose of this Dissertation is to document the conceptualization and development of practical methods of Non-Invasive Thermal Interrogation (NITI) as pertains to a few example and non-limiting applications. This includes the design of novel NITI sensor technology and apparatus as well as different signal processing and interrogation techniques.","abstract_has_math":false,"creators":["Roghanizad, Ali Reza"],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Diller, Thomas E."],"committee_members":["Van Dyke, Mark","Huxtable, Scott T.","Vick, Brian","Robertson, John L."],"year":2020,"date_issued":"2020-07-10","date_published":"2020-07-10","updated_at":"2026-07-22T22:19:04Z","subjects":["Core Body Temperature","Blood Perfusion","Heat Flux","Temperature","Non-Invasive Thermal Interrogation","Non-Destructive Testing","Bio-Instrumentation","Wearables"],"languages":[],"rights":["This item is protected by copyright and/or related rights. Some uses of this item may be deemed fair and permitted by law even without permission from the rights holder(s), or the rights holder(s) may have licensed the work for use under certain conditions. For other uses you need to obtain permission from the rights holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:25581"],"render_values":[{"text":"vt_gsexam:25581","href":null,"code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10919/117281","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Diller, Thomas E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Van Dyke, Mark","Huxtable, Scott T.","Vick, Brian","Robertson, John L."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Roghanizad, Ali Reza"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-02T07:00:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-02T07:00:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-07-10"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Core Body Temperature","Blood Perfusion","Heat Flux","Temperature","Non-Invasive Thermal Interrogation","Non-Destructive Testing","Bio-Instrumentation","Wearables"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This item is protected by copyright and/or related rights. Some uses of this item may be deemed fair and permitted by law even without permission from the rights holder(s), or the rights holder(s) may have licensed the work for use under certain conditions. For other uses you need to obtain permission from the rights holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:25581"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/117281"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Non-Invasive Thermal Interrogation (NITI) is a form of non-destructive testing (NDT) that uses simultaneous measurements of object surface heat flux and object surface temperature. When these measurements are combined with signal processing algorithms, such as parameter estimation routines or other techniques, they can be used to non-invasively determine the internal temperature and parameters of the object in real-time. Consequently, NITI has a number of applications in the, for example, bio-medical, industrial, food safety, and wearable industries. The purpose of this Dissertation is to document the conceptualization and development of practical methods of Non-Invasive Thermal Interrogation (NITI) as pertains to a few example and non-limiting applications. This includes the design of novel NITI sensor technology and apparatus as well as different signal processing and interrogation techniques."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Non-Invasive Thermal Interrogation (NITI) is a new Non-Destructive Testing (NDT) technology that is based on an advanced and novel form of thermal sensing. What is unique about NITI is a thermal sensing approach where surface measurements of both temperature and heat transfer (e.g., heat flux) are recorded. This enables NITI as a non-invasive, surface mounted technology that can accurately monitor and determine object internal properties. Object internal properties include internal parameters (e.g., thermal conductivity, heat capacity, etc.) as well as object internal temperature. In this Dissertation, a particular emphasis is on bio-medical applications of NITI, where the technology is adapted to non-invasively measure human core body temperature and tissue blood flow in real-time."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["The Development of Novel Apparatus, Systems, and Methods for Non-Invasive Thermal Interrogation (NITI)"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Diller, Thomas E."],"dc:contributor.committeemember":["Van Dyke, Mark","Huxtable, Scott T.","Vick, Brian","Robertson, John L."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Roghanizad, Ali Reza"],"dc:date.accessioned":["2024-01-02T07:00:09Z"],"dc:date.available":["2024-01-02T07:00:09Z"],"dc:date.issued":["2020-07-10"],"dc:description.abstract":["Non-Invasive Thermal Interrogation (NITI) is a form of non-destructive testing (NDT) that uses simultaneous measurements of object surface heat flux and object surface temperature. When these measurements are combined with signal processing algorithms, such as parameter estimation routines or other techniques, they can be used to non-invasively determine the internal temperature and parameters of the object in real-time. Consequently, NITI has a number of applications in the, for example, bio-medical, industrial, food safety, and wearable industries. The purpose of this Dissertation is to document the conceptualization and development of practical methods of Non-Invasive Thermal Interrogation (NITI) as pertains to a few example and non-limiting applications. This includes the design of novel NITI sensor technology and apparatus as well as different signal processing and interrogation techniques."],"dc:description.abstractgeneral":["Non-Invasive Thermal Interrogation (NITI) is a new Non-Destructive Testing (NDT) technology that is based on an advanced and novel form of thermal sensing. What is unique about NITI is a thermal sensing approach where surface measurements of both temperature and heat transfer (e.g., heat flux) are recorded. This enables NITI as a non-invasive, surface mounted technology that can accurately monitor and determine object internal properties. Object internal properties include internal parameters (e.g., thermal conductivity, heat capacity, etc.) as well as object internal temperature. In this Dissertation, a particular emphasis is on bio-medical applications of NITI, where the technology is adapted to non-invasively measure human core body temperature and tissue blood flow in real-time."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:25581"],"dc:identifier.uri":["https://hdl.handle.net/10919/117281"],"dc:publisher":["Virginia Tech"],"dc:rights":["This item is protected by copyright and/or related rights. Some uses of this item may be deemed fair and permitted by law even without permission from the rights holder(s), or the rights holder(s) may have licensed the work for use under certain conditions. For other uses you need to obtain permission from the rights holder(s)."],"dc:subject":["Core Body Temperature","Blood Perfusion","Heat Flux","Temperature","Non-Invasive Thermal Interrogation","Non-Destructive Testing","Bio-Instrumentation","Wearables"],"dc:title":["The Development of Novel Apparatus, Systems, and Methods for Non-Invasive Thermal Interrogation (NITI)"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:04Z"}